|
|
Advertisement
|
|
Laboratory and Research Supplies and Equipment ->
Cleanroom Equipment & Supplies
Cleanroom Equipment & Supplies
(Showing headlines 61 - 80) 1 2 3 4 5 6
|
 Filtered Storage Cabinet removes airborne contamination.Clean Air Products Clean Air Systems Div.
Minneapolis, MN 55445 1828
Nov 23, 2004 Cleanroom Series 91HF uses aluminum framed, motorized HEPA filter for ~100% interior cabinet ceiling coverage. Filter provides ~650 cfm laminar flow to remove airborne contamination from cabinet and garments as they are taken and returned to rack. Constructed with 16-gauge, cold-rolled steel, cabinets are available with adjustable wire or perforated shelves and measure 25 x 49 x 95 in. Garment pole accommodates 24 garments with 2 in. spacing. |
 Static Conductive Hose can be used around explosive gases.Hi-Tech Duravent
Georgetown, MA 01833
Oct 20, 2004
Suited for use where potential for static buildup in presence of explosive gases exists, EDW-SC PVC-coated, polyester duct has PVC wearstrip and enclosed wire helix with belted and cuffed ends. Flexible hose, manufactured using thermal welding and without adhesives, is compressible to facilitate storage. Conductive throughout, product provides resistivity from 1 x 105 to 1 x 1012 ohm and is offered in 8, 10, and 12 in. ID sizes in varying lengths.
|
 Cleanroom Gowning Benches offer under-the-seat storage.Eagle MHC
Clayton, DE 19938
Oct 19, 2004 Designed to meet needs of Class 1 to Class 100,000 cleanroom operations, benches feature wire undershelf for storage of booties and other clothing articles. Users can choose from stainless steel or chrome plated wire benches featuring 3-sided channel frame and 62% laminar flow. Available in 5 standard lengths from 36–84 in., models are also offered with stainless steel perforated tops. Solid-seat gowning benches feature front-to-back crossbracing. |
 Storage Cabinet is cleanroom-compatible.Clean Air Products Clean Air Systems Div.
Minneapolis, MN 55445 1828
Sep 28, 2004 Constructed with 16-gauge, cold-rolled steel and finished with white baked enamel, Series 91SC will not crack or harbor contamination. It comes with 5 solid shelves in 4 standard sizes, and custom sizes are available upon request. All units are suitable for cleanroom applications. |
 Glovebox provides high level of containment.Baker Co., The
Sanford, ME 04073
Aug 12, 2004 IsoGARD® Series Class III glovebox, designed for research involving agents assigned to BSL-3 or -4 facilities, features plug-and-seal, canister-style HEPA exhaust filters. Supply HEPA filter, protected with 316L stainless steel diffuser, covers entire ceiling of primary working chamber. Offered in 3 models with 2-, 3-, and 4-glove primary working chambers, product has front-opening, glass-panel door and stainless steel gloveports with single-piece, sleeve-and-glove assembly. |
 Cleanroom Vacuums are HEPA or ULPA filtered.Atrix International, Inc.
Burnsville, MN 55337
Jul 21, 2004 Omega Series vacuums filter exhaust air and exceed cleanroom class 100,000 standards. Featuring EMI/RFI suppression, ESD-safe units include HEPA or ULPA cartridge filter, 10 ft ESD-safe hose, and 16 in. ESD-safe rubber gooseneck to clean sensitive manufacturing equipment, electronics, cabinets, computers, and copy machines. Optional accessory kit offers two 20 in. straight wands, 11 in. curved neck, 10 in. rough floor wand, 10 in. floor wand, and caddy. |
 Dust Containment Cabinets maintain cleanrooms.Clean Air Products Clean Air Systems Div.
Minneapolis, MN 55445 1828
Jul 20, 2004 Series 1532 Inflow Dust Containment Cabinets, constructed of painted steel, incorporates blower on top of unit that draws air into pair of wall-mounted filters. HEPA filter system consists of 2 parts: absolute HEPA filter and flexible duct to form modular component. Cabinets provide 2 stages of filtration before HEPA filter: disposable, non-woven framed fiberglass media and optional charcoal filter. Units are offered in widths of 4–6 ft and heights of 6–12 ft. |
 Modular Cleanrooms offer Class 100 to Class 10 protection.Clean Air Products Clean Air Systems Div.
Minneapolis, MN 55445 1828
Jun 17, 2004 Series 558 Vertical Flow Hardwall Cleanrooms are made from 16-gauge, cold-rolled steel with white baked enamel or powder coat finish. Each includes full-ceiling HEPA filter coverage with plenum sections that provide uniform filtered laminar air flow to clean areas, with filtered air going to 100% of available ceiling surface. Sidewall blower cabinets blow air into upper filter plenums. Sidewall panels contain start/disconnect, wall receptacles, and prefilters. |
 Flow Sensor monitors laminar flow in clean rooms.Schmidt Feintechnik GmbH
Germany
Jun 04, 2004 SCHMIDT® flow sensor SS 20.515 features single-point fixture that can be adapted to ceiling systems. Sensor tube positions sensor tip at correct distance from LF ceiling, allowing it to be rotated into optimum position. Sensor incorporates smooth sensor tip, without edges, and can be supplied in H2O2 or alcohol disinfection versions. Operating from 24 Vdc/110 mA power supply, sensor has 0–1 m/s measuring range and 4–20 mA output. |
 Air Locks help eliminate cleanroom contamination.Clean Air Products Clean Air Systems Div.
Minneapolis, MN 55445 1828
May 06, 2004 Series 18 Pass Thru Air Locks transfer parts and equipment into and out of cleanrooms. Units are made of ˝ in. sheets of polypropylene welded together, providing solid plastic air lock entry system that prevents deterioration. Doors feature stainless steel frame and continuous hinges, plexiglass viewing window, closed-cell PVC door gasket, and 90° turn-knob latch, or cam-action chrome-plated latch on larger units. Stainless steel airlocks are optional. |
 Ceiling Modules provide cleanroom level air filtration.Camfil Farr
Riverdale, NJ 07457
Mar 30, 2004 Replaceable PharmaSeal® Ducted Ceiling Modules feature guillotine-type control damper with adjustable linkage. Airflow may be adjusted from 10–98% of rated filter flow. Available in 0.063 aluminum or 16 GA 304 stainless steel, modules may be installed in T-bar ceilings or flush-mounted in plaster or sheet rock ceilings. Gel seal filters offer removal efficiencies from 95% at 0.3 micron to 99.9995% at 0.12 micron. |
 Cleanroom Tables feature heavy-duty construction.Clean Air Products
Minneapolis, MN 55445 1828
Feb 17, 2004 Rated for use in cleanrooms from Class 100,000 to Class 10, Series 61 Formica tables feature heavy-duty design for corrosion-resistant operation. Tabletop measures 1.125 in. deep and features solid wood core completely covered with high-pressure plastic laminate. Work surface, mounted on stainless steel support frame, has square tubular steel support legs and adjustable leg-leveling guide. Static dissipative models are also available. |
 Clean Benches meet Class 100 cleanroom conditions.Clean Air Products
Minneapolis, MN 55445 1828
Dec 23, 2003 Series 201 Horizontal Flow Clean Benches remove 99.99% of particulate contaminants 0.3 micron and larger. They feature wrap-around design with white Vinclad steel for resistance to abrasion, corrosion, stains, chemicals, and general wear. Cabinet maximizes usable work space, while assuring clean laminar airflow through work area by eliminating turbulence and back currents. HEPA filter is accessible from front of unit for easy maintenance. |
 Vacuum Cleaners offer disposable collection container.Nilfisk-Advance America, Inc.
Malvern, PA 19355
Dec 12, 2003 When integrated with CFM 3156 and 3306 vacuum cleaners, Safe-Pak® HEPA-filtered collection unit enables workers to safely collect, handle, and dispose of potent pharmaceutical compounds. When Safe-Pak is full, users dispose of entire container, virtually eliminating risk of contamination and exposure. Each vacuum features multi-stage HEPA filtration system that traps and retains 99.999% of particles, down to and including 0.3 microns in size.
|
 Clean Air Enclosures suit high-volume robotic applications.Baker Co., The
Sanford, ME 04073
Oct 31, 2003 BioPROtect® II and BioPROtect® Jr. are Class II-style clean air and containment enclosures that provide HEPA-filtered, particulate-free airflow throughout work area, protecting personnel, product, and environment. Enclosures accommodate robotic systems, ultra-centrifuges, flow cytometers, aerosol generators, and other pieces of laboratory equipment. Applications include high-throughput screening, combinatorial chemistry, immunology, and clinical research. |
 Soft-Wall Cleanrooms control particulate.Clean Air Products
Minneapolis, MN 55445 1828
Aug 13, 2003 Series 575 Soft-Wall Enclosures provide freestanding cleanroom environment for Class 100,000 to Class 10 and can provide open spans up to 32 ft with no center supports. They include motorized ceiling HEPA filters, lights, ceiling panel, tee bars, and prefab wiring. NEST TIGHT ceiling grid system provides zero-leak ceiling for optimum performance. Variety of shapes and sizes suit specific application requirements. |
 Cleanroom Garments suit Class 1 to Class 100 environmentsGore, W. L., & Associates, Inc., Industrial Filtration Technologies
Elkton, MD 21921
Jun 13, 2003 GORE-TEX® Cleanroom Garments, offered in 22 sizes, provide breathable comfort and flexible fit. Featuring 99.9999% filtration efficiency at 0.12 microns, fabric provides contamination barrier while allowing release of body heat and perspiration vapor. GORE-TEX fabric is non-shedding, anti-static, and flame- and chemical-resistant. Garments offer full zipper fronts, raglan sleeves, elastic waists, and stretch fabric closures at collar and cuffs. |
 Soft Wall Cleanrooms feature modular construction.Clean Air Products
Minneapolis, MN 55445 1828
May 08, 2003 Series 550 vertical flow cleanrooms provide energy efficiency and include full-ceiling HEPA filter plenum sections. All metal construction provides durability and ease of maintenance. Various configurations are available to satisfy application requirements. |
Pre-Separator prevents material from contaminating system.Nilfisk-Advance America, Inc.
Malvern, PA 19355
May 08, 2003 Filtered, pre-separator heavy-duty collection tank can be integrated into central vacuum systems and reduces threat of cross-contamination in pharmaceutical manufacturing. Unit connects to central system's outlets, and is powered by system's suction. All powders are filtered and held within pre-separator's tank. Materials of 0.3 µ are retained with multi-stage HEPA filtration system that is approved for cleanrooms to ISO 5, Class 100.
|
 Automatic doors have opening speed of 48 ips.Nergeco USA
West Chester, OH 45069
May 07, 2003 Agro 5 Forum and Labo 5 Forum high-speed doors are for clean room applications where sanitary conditions are a must. Washable, ergonomic doorframes are created from composite material and include company's patented re-insertion guides which reinsert curtain into side guides without human intervention. Doors feature soft-bottom edge, two sets of thru beam photo sensors, NEMA 4X watertight control panel, and optional vision panels. |
(Showing headlines 61 - 80) 1 2 3 4 5 6
|
|
|