HVAC

HVAC

Fans provide low blade tip noise and quiet operation.

Dec 21, 2001

8X Series Multi-Wing Fans feature twisted broad paddle profile blade which produces high air volume and pressure at low speeds. They are made with fiberglass reinforced polypropylene blades and cast-aluminum hubs. Corrosion-resistant materials provide service in harsh environments such as HVAC and chemical applications. Fans are available with 3, 4 or 5 blades, with adjustable blade pitch. Any... Read More

Chemicals & Chemical Processing, HVAC

Mist and Smoke Eliminator is rated at 1250 CFM.

Dec 21, 2001

MistBuster II utilizes 3-stage filtration process to eliminate mist and smoke from airstreams. Mechanical mist impingers capture larger mist droplets, electrostatic precipitator (ESP) provides intense electrical charge on remaining contaminates, and aluminum post-filter entraps particles that may have been agglomerated on cell plates. MistBuster runs at noise levels rated to 70dBA @ 6 feet on... Read More

Controls & Controllers, HVAC

Blowers, Fans and Thermostat come in different models.

Dec 17, 2001

3-phase 200 to 230 Vac blower models MB810-T and MB1225-T have impeller diameters of 3.15 and 4.72 in., respectively. MB810-T produces maximum airflow of 56.5 cfm at 2800 rpm to 63.6 cfm at 3350 rpm, while MB1225-T produces 155 cfm at 2850 rpm to 184 cfm at 3300 rpm. MBD Series DC centrifugal blowers include blowers with both 3.15 and 3.94 in. impeller diameters. Airflows range from 51.2 cfm at... Read More

HVAC

Mail Inspection Workstation protects mail sorters.

Dec 17, 2001

Fumes, powders and contaminants are drawn down and away from inspectors' breathing area through 2,500 perforations in table top and vented back. System is self-contained, and all air is filtered through 99.97% efficient HEPA filter. Clean air is returned to room. Machine runs at noise level of 68 dB, and requires 115 V single-phase input power. Read More

HVAC

Air Purifiers are designed for compressed air systems.

Dec 13, 2001

Del-Monox® Breathing Air Purifiers, ranging from 8 to 920 scfm, remove particulates, oil, moisture, tastes, odors, and carbon monoxide from untreated compressed air. Supplied air meets OSHA Grade D and Canadian Standards Association (CSA) maximum allowable contaminant levels for compressed breathing air. Purifiers provide built-in color change monitoring and maximum carbon monoxide conversion... Read More

HVAC, Material Handling & Storage

Air Compressor saves energy by adjusting to demand.

Dec 13, 2001

Variable speed drive on LS-1 6V compressor optimizes compressor output by matching system demand and saving energy. Control system also provides optimum part-load control. Compressor is available in 75 and 100 hp models with 225 to 450 cfm output and pressure ratings of 100 to 175 psig. Air-cooled and water-cooled models are available. Supervisor Controller has built-in sequencing capabilities... Read More

HVAC, Material Handling & Storage

Compressor Controller sequences multiple units.

Dec 13, 2001

Supervisor Controller monitors and controls compressor, and communicates via RS485 and RS232 ports. Dual control provides lead-lag and sequencing with multiple compressors. Unit has 4-line, full-text display for constant readout of pressure and temperature, on-demand readout of operating and maintenance conditions, monitoring of key functions and safety shutdowns, and power failure auto re-start. Read More

HVAC

Refrigerant protector prevents pump-out.

Dec 11, 2001

Purge-Guard, for all low-pressure centrifugal chiller purge units, works independently of purge units' purge-fault protection. In the event of problems such as stuck pump-out compressor relay contacts, locked-up microprocessor, or purge unit set in manual mode and accidentally left unsupervised, Purge-Guard prevents accidental pump-out of either liquid or vapor refrigerant. Read More

HVAC

Sigma Screw Compressors offer sigma frequency control.

Dec 11, 2001

Sigma Screw Compressors with Sigma Frequency Control (SFC) are available with 100-215 hp and flows from 130-1001 cfm to provide pressures from 80-145 psig. Direct drive airend/motor package is designed to provide 20-100% efficiency over its entire speed range. SFC can run fully loaded for indefinite periods of time. SFC compressor packages feature sound dampening enclosures, EPAct compliant... Read More

Electrical Equipment & Systems, HVAC, Material Handling & Storage

Generator/Air Compressor also provides tool storage.

Dec 11, 2001

Power Pack, with Kohler 5000 W, continuous-duty generator set and Ingersoll Rand 11.3 cfm @ 90 psi Air Compressor, provides power for uses such as supporting 130 A wire feed welder, air wrenches and nail guns, and emergency power needs. Locking control panel has 120V and 240V outlets. Aluminum tread-plate box, with 2.8 cu ft storage area, holds wire-feed welder, enlarged fuel tank, power tools or... Read More

HVAC, Sensors Monitors & Transducers, Test & Measuring Instruments

Temperature Assemblies provide surface measurements.

Dec 11, 2001

WORM Flexible Sensor coupled with PC-Programmable or Smart HART® Temperature Transmitters mounts directly to tanks, pipes, motors, compressors, or reactors when surface temperature measurement is needed. Spring-loaded, flexible sensor trims-to-length for easy installation. Stainless steel mounting accessories allow assemblies to endure harsh field environments. Read More

Electrical Equipment & Systems, HVAC, Sensors Monitors & Transducers

Active Flow Switch works in pipes up to 4 ft dia.

Dec 07, 2001

FS30 flow switch works with any of company's flow sensors to send output at set flow rate. It can be inserted in pipe sizes 1/2 to 48 in., mounted on sensor or remotely, and set to activate on rise or fall. Set point is input using rotary digital switches. Switch has variable hysteresis or deadband setting to accommodate varying amounts of turbulence. If turbulence is significant, deadband keeps... Read More

Chemicals & Chemical Processing, HVAC

Pleated Filter meets ASHRAE 52.2 Standard.

Nov 30, 2001

Type DP8 pleated panel filter has media made from 100% synthetic fibers enhanced with electrostatic charge to increase efficiency on particles sized one micron and below. It meets MERV8 rating per ASHRAE Standard 52.2 and provides 30-35% dust spot efficiency per ASHRAE Standard 52.1. Media is pleated with galvanized steel expanded metal backing to form consistently shaped pleats and prevent rust.... Read More

HVAC

Underfloor Fan installs between raised floor pedestals.

Nov 28, 2001

Energy efficient Model UFT variable speed fan accommodates varying heating and cooling loads in perimeter zone and interior rooms. It delivers up to 1798 cfm. Units are available with hot water or electric reheat coils to offset cold downdrafts at exterior of building. For interior rooms, where only cooling is required, units without reheat coils may be specified. Read More

HVAC

Filter Vent is designed for dry bulk material bins.

Nov 20, 2001

Fast Filter Bin Vent is made of carbon steel, with solenoids pre-wired and plumbed. It has smart timer, DP transmitter and digital readout. Vents are available from 400-2200 CFM with 79 to 430 sq ft of filter media. Vents are shipped complete with galvanized cages, bag cups, venturis, and 16 oz. polyester (dacron) bags. Read More

HVAC

Brushless DC Blower cools compact electronics.

Nov 17, 2001

Measuring 5.30 in. square by 1.35 in. deep, Airbox DC Blower delivers 30 cfm and static pressure of 0.7 in. of water, while generating minimal noise of 46.6 dB. ThermaPro-V(TM) technology automatically adjusts airflow based on temperature needs. Automatic restart feature ensures operation will resume after power failure or overheating. Both housing and polypropylene impeller meet UL 94V-0... Read More

HVAC

Coolants are designed for grinding applications.

Nov 16, 2001

Microcool(TM) functional fluids, available in wide selection of viscosity ranges, are suitable for grinding operations that shape, sharpen and resharpen carbide, tool steel and stainless steel tools. Fluids work with or without chilling device and are compatible with diamond, CBN or vitrified wheels. They have a great tolerance for contamination, even after extended use. Read More

HVAC, Sensors Monitors & Transducers, Test & Measuring Instruments

System provides non-contact temperature measurement.

Nov 16, 2001

Series IM/IMS combines IM Panel Meter with IMS IR Sensor to form complete monitoring system. IM 1/8 DIN panel meter displays temperature from 0 to 1000°F (-18 to 538°C) on 4-digit LED. It provides user-defined 4-20 mA or thermocouple output as well as adjustable dual setpoints and deadband alarm outputs. Infrared Sensors are available with distance-to-target ratio (35:1) or close focus... Read More

HVAC

Steel Cooler keeps lube oil cool.

Nov 15, 2001

SX2000 is a compact, thermally efficient unit made of carbon steel with copper tubes. Several other tubing materials are available. Cast-iron bonnets, available in single, 2, and 4-pass configurations, are kept in stock, as are cores. Unit is suitable for lube oil cooling and other process-cooling applications, and is dimensionally interchangeable with similar models. Read More

HVAC

Fume System collects all types of dust.

Nov 15, 2001

Mobile FCS provides up to 99.5% clean air for environments which involve brazing, dry chemicals, machining, laser and plasma cutting, sanding, powders, soldering and welding. It handles carbon, plastic and rubber dust as well as fugitive emissions. Unit has automatic jet pulse system with 5-gal recovery tray, extraction arm that extends to more than 9 ft, and hood with damper and halogen light.... Read More