|
|
|
|
|
Controls & Controllers
(Showing headlines 61 - 80) << 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 ...
|
 Ball Guide Screw Linear Rail features integrated IDEA Drive.Haydon Kerk Motion Solutions
Waterbury, CT 06705
Apr 09, 2013
RoHS-compliant BGS06 utilizes size 17 single- or double-stack stepper motor linear actuator with programmable stepper motor controller. For rigid, smooth motion, precision rolled 303 stainless steel lead screw with Black Ice® TFE coating drives precision nut embedded in machined aluminum carriage mounted to stainless steel ball rail. Max stroke length is 24 in., max horizontal load is 135 lb, and respective moment load capacities for roll, pitch, and yaw are 11.62, 7.93, and 9.15 lb-ft.
|
 Compact Intelligent Drives are equipped with CAN interfaces.Technosoft S.A.
Switzerland
Apr 08, 2013
Based on closed-frame intelligent drive concept, iPOS3602 BX-CAN and iPOS3604 BX-CAN control rotary or linear brushless, DC brush, and step motors with rated powers up to 144 W and 36 V nominal voltage. Respectively, models can drive 2 and 4 A continuous currents as well as 3.2 and 10 A peak currents at supply voltage from 12–36 Vdc with PWM of 20 kHz. Supplied in 80 x 55 x 16 mm, 70 g package, servo drives offer single- or multiple-axis control functions.
|
 Biomass Camera System enables real-time combustion monitoring.Lenox Instrument Co.
Trevose, PA 19053 3427
Apr 05, 2013
Equipped with compressed air cooling system, FireSight provides real-time monitoring of combustion process inside boilers, furnaces, and incinerators burning renewable biomass fuels and other traditional/non-traditional fuels. Wall Box Mounting Assembly serves as protective housing and primary coolant shroud, enabling system to survive in environments up to 3,000°F. With light volume control feature, operator in control room can adjust amount of light transmitted to camera, eliminating bloom.
|
 Spray Valve Control System provides repeatable performance.Fisnar Inc.
Wayne, NJ 07470
Apr 05, 2013
Available in 3, 12, and 18 mm spray paths, SV2000N minimum overspray valves are suitable for urethanes, flux, and silicone coatings. Valves are actuated by air pressure sequenced by SVC100 controller. Air pressure opens needle in valve allowing material to flow, while separate air-line creates pressure in valve exit cap, atomizing fluid. Controller sequences time relationship between fluid start signal and atomizing signal, which is critical in cleaning spray nozzle after each spray cycle.
|
 Turnstile Remote Control Panel provides touchsceen intuition.Boon Edam Inc.
Lillington, NC 27546
Apr 05, 2013
BoonTouch Universal Remote Control Panel enables management of Boon Edam turnstiles and gates, which ensure only authorized users are allowed to enter secured area. Optimized for usability, capacitive touchscreen control panel's UI lets operators open/close each individual turnstile or gate automatically as well as manage settings for entire bank of up to 6 lanes. Additionally, users can monitor lane usage and receive alarms prompted by unauthorized access or other problems.
|
 Programmable Logic Controller extends communications options.Siemens AG
Munich D-80333 Germany
Apr 04, 2013
Featuring CP 1542-5 communication processor that enables connection to Profibus networks, Simatic S7-1500 supports Profibus-DP master and slave functions according to IEC 61158/61784 as well as S7 routing. Security functions have been extended in CP 1543-1 communication processor used to connect to Industrial Ethernet networks; one provides additional encryption of data communicated to controller. In addition to access protection functions, CP 1543-1 offers stateful inspection firewall.
|
Automatic Start/Stop helps diesel engines conserve fuel.Volvo Penta Of The Americas, Inc.
Chesapeake, VA 23320
Apr 04, 2013
Automatic start/stop option for Volvo Penta industrial diesel engines can achieve fuel savings of 5% or more by switching engine off when idling and consequently helps reduce emissions and noise. When machine's engine idles, this option turns engine off after pre-set time (usually 5–10 sec). Engine starts immediately when driver activates any of machine's controls, and work can continue. Start/stop capability can be deactivated or reactivated as needed.
|
 Trip Amplifiers protect hoists and cranes against overload.LCM Systems Ltd.
Isle of Wight PO30 5GY United Kingdom
Apr 03, 2013
Providing dual volt-free relay outputs from load cell signal, LCTA Series Load Cell Trip/Relay Amplifiers offer hoist overload protection, safe crane lifting control, and personnel lifting platform protection. Units can power single load cell or load pin, or up to four 350 Ω load cells connected in parallel. Volt-free relay outputs have trip switching current of 10 A at 230 Vac and can be adjusted independently. For remote display, amplifiers also include 0-5 V analog output.
|
Step Down Voltage Regulator delivers max load current of 2 A.Exar Corp.
Fremont, CA 94538
Apr 03, 2013
With operating input voltage up to 18 V, PowerBlox™ XRP7674 achieves better than 90% efficient conversions for output current as low as 50 mA. Synchronous current mode PFM/PWM buck regulator operates at fixed 340 kHz switching frequency, with output voltage adjustable down to 0.925 V and ±2% accuracy across operating range. Housed in RoHS-compliant, halogen-free 8-Pin SOIC package, regulator is suited for set-top boxes, telecom, computing peripherals, and distributed POL conversions.
|
 Mobile App provides VMS control from tablets, smartphones.Vicon Industries Inc.
Hauppauge, NY 11788
Apr 02, 2013
Supported by ViconNet web/mobile server that transcodes and streams video to mobile users, Vicon Mobile lets ViconNet video management system (VMS) users view live and recorded video from any device on their network via iPhones and iPads or Android phones and tablets. Mobile app provides full control of PTZ cameras as well as playback access. Interface includes pinch-to-zoom functionality on live and recorded video, and video tiles can be arranged on screen with touch-and-drag motion.
|
 Transmitter supports batch controller capabilities.GF Piping Systems
Tustin, CA 92780-7258
Apr 02, 2013
Signet 9900 Transmitter (Generation II) supports multiple parameters, including flow, pH/ORP, conductivity/resistivity, salinity, temperature, pressure, level, and 4–20 mA signals, and batch systems. In addition to saving up to 10 batch sizes, capabilities include customizable batch names, entry of K-factors for each batch, confirmation for preventing accidental batch starts, manual batch feature for topping off, override batch size function, and batch count indicator.
|
 Programmable Logic Controller provides network redundancy.WAGO Corp.
Germantown, WI 53022
Apr 02, 2013
Capable of withstanding constant shock and vibration, Model 750-885 Media Redundancy Controller features 2 redundant networks backed by dual, independent Ethernet interfaces and 1 MB of data memory. Ethernet ports permit operation over independent networks and paths, which are accessible via different IP addresses and MAC IDs. If Path 1 fails, Path 2 resumes communication. Providing up to 32 GB of extra memory, SD card supports back-up-and-restore, file transfer, and time-stamping/data logging.
|
 Ultra-LDO Linear Regulators suit high-current POL conversion.Advanced Power Electronics Corp
San Jose, CA 95118
Apr 01, 2013
Designed to provide POL DC-DC conversion in board-level applications, Series APE8968MP-HF3 provides dropout of just 0.23 V at 3 A. Units require 2 supply voltages, one for control circuitry and another for main supply. Power-On-Reset circuit monitors both supply voltages to prevent incorrect operation. Available in ESOP-8 package, regulators include thermal shutdown and current limit protection, as well as POK that indicates output status with time delay that is set internally.
|
 Modbus Gateway supports serial to Ethernet conversion.Artila Electronics,. Co., Ltd
Taipei 231 Taiwan
Mar 28, 2013
Equipped with two configurable RS-232/485 serial ports and one 10/100 Mbps Ethernet port, Aport-212 provides 2-way Modbus TCP to Modbus RTU/ASCII communication conversion. Unit supports up to 16 Modbus TCP masters and 32 Modbus slaves in almost any mode combination simultaneously. Built with 32-bit ARM Cortex M3 processor, gateway offers web-based configuration and utilizes analyzer utility software to test and debug Modbus protocol in field.
|
Reference Design supports automotive emergency call systems.Texas Instruments, Inc. (TI)
Dallas, TX 75243-4136
Mar 28, 2013
Integrating AEC-Q100 qualified components, Automotive eCall Reference Design includes TPA3111D1-Q1 mono Class D audio amplifier; TPS43330-Q1 single-boost, dual synchronous buck controller; TLV70033-Q1 voltage regulator; and MSP430F2232 16-bit microcontroller. TPA3111D1-Q1 delivers 10 W output power at 8 Ω with greater than 90% efficiency, while TPS43330-Q1 supports automotive start/stop and boosts back-up battery supply voltage, allowing operation down to 2 V at input.
|
Flyback Controller surpasses Energy Star® 5 requirements.Texas Instruments, Inc. (TI)
Dallas, TX 75243-4136
Mar 27, 2013
Used with WEBENCH® online design tool, LM5023 simplifies and accelerates high-voltage DC/DC designs. This isolated quasi-resonant PWM controller with integrated 700 mA driver offers efficiency up to 90% and consumes less than 10 mW in standby. Output voltage regulation accuracy of 1% over line, load, and temperature eliminates need for cable compensation. Supplied in 8-pin MSOP, controller offers quasi-resonant operation that improves efficiency while lowering EMI emission.
|
 Temperature Controllers offer full PID operation.West Control Solutions
Gurnee, IL 60031
Mar 26, 2013
Equipped with menu for programming, Models 3300, 9300, and 9400 regulate temperature in variety of applications, including plastics, packaging, drying, and laboratory equipment. Units feature IP66-rated smoked plastic fascia and rubberized buttons with positive feedback. Offering tool for process monitoring and controller configuration, CALgrafix software provides data logging, process data archiving, and chart recording, as well as virtual instrument display and on-screen alarm display.
|
Digital Power Controller minimizes server downtime.Texas Instruments, Inc. (TI)
Dallas, TX 75243-4136
Mar 26, 2013
Equipped with 64 KB of program Flash memory for AC/DC and isolated DC/DC power supplies, Model UCD3138064 allows designers to implement firmware upgrades on-the-fly without shutting off power supply. Memory partitioning architecture gives users ability to simultaneously write to and execute from different portions of on-chip memory and dynamically switch execution between various firmware images using appropriate algorithms. Communication options include UART, PMBus™, I2C, and SPI.
|
Polarization Control Instrument offers pre-selected states.Phoenix Photonics Ltd
Surrey United Kingdom
Mar 26, 2013
Firebird utilizes technique that provides user-programmable state of polarization anywhere on Poincare Sphere. Facilities for user programming are included that enable users to select any state in order to program and switch between pre-selected states. This all-fiber polarization controller ensures max power throughput at selected state and also incorporates built-in method to move plane of output polarization.
|
Digital Power Controller includes PMBus interface.Analog Devices, Inc.
Norwood, MA 02062-9106
Mar 25, 2013
Housed in 4 x 4 mm LFCSP package, Model ADP1051 targets high-density, isolated DC-to-DC power supply systems with parallel/redundant capability. Controller features 6 PWM logic outputs that can be programmed using GUI via PMBus interface. Device enables high energy efficiency topologies including full bridge and active clamp forward variants with precision drive timing and control of secondary synchronous rectifiers. Energy efficiency is further optimized using adaptive dead-time compensation.
|
(Showing headlines 61 - 80) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268
|
|
|