HVAC ->
Ventilation Equipment ->
Dampers
Dampers
(Showing headlines 21 - 33) 1 2
|
 Vibration Damper is RoHS-compliant.Richco, Inc.
Morton Grove, IL 60680
Dec 28, 2005
VD Series is designed with TPE center that provides shock and vibration protection as well as blind hole ends that provide rigid mounting in wood, particle board, and threaded metal or plastic. Ends are molded in flame-retardant UL94 V0 Nylon 6/6, and hand-installed parts accept range of panel thicknesses.
|
 Dampers provide constant speed motion control.Guden, H. A., Co., Inc.
Ronkonkoma, NY 11779
Jul 26, 2005 Compression and extension dampers are force-absorbing devices used where load or door must be lowered or swung in controlled motion at constant speed. Products are offered in rod/tube diameter sizes from .24 x .59 in. to .315 x .87 in., with stroke lengths from 2–7 in., extended lengths from 7.9–19.7 in., and max load capacities from 50–100 lb. Custom dampers are available in lengths to 26 in. with stroke to 10 in, and all dampers may be double-damped. |
Air Control Damper uses Lon-based programmable controller.Greenheck
Schofield, WI 54476 0410
Jun 23, 2005 Aluminum airfoil blade damper, Model IAQ-42 utilizes Speciflowâ„¢ technology with integrated airflow monitoring and control. It features rated accuracy of 5% of reading for face velocities of 300–2,000 fpm. Damper helps buildings meet minimum outdoor air requirements for ASHRAE Standard 62 and California Title 24. Unit is IECC compliant with leakage rating of 3 cfm/ft² at 1 in. wg or less. |
 Insulated Control Damper has thermally broken frame.Greenheck
Schofield, WI 54476 0410
Jan 17, 2005 Suited for outdoor air intake systems, Model ICD incorporates damper frame that has 2 thermal breaks with dual polyurethane resin gaps and is insulated on all 4 sides with polystyrene. Blades are thermally broken and filled with polyurethane for insulating characteristics. Product's design reduces transfer of heat or cold and virtually eliminates condensation. |
 Snap-Fit Rotary Damper aids in opening doors.Richco, Inc.
Chicago, IL 60680
Oct 07, 2004 Available in 20 gf.cm and 40 gf.cm torque variations, RFRT-XXG-CLIP series aids in smooth opening of compartment or door. Snap-in design negates need for separate screws or ultrasonically welding this part. Push and snap-in motion holds damper firmly in place with its fixing wings. Using designated cut out in panel/chassis, damper is pushed into place through panel/chassis, exposing gear to integrate with toothed rack of compartment door. |
 Tabletop Isolator uses active feedback control system.Kinetic Systems, Inc.
Boston, MA 02131
Aug 24, 2004 Available in 4 sizes, Series 8001 Active Electronic Vibration Isolation Platform isolates instruments from 6 translational and rotational modes of vibration. Portable unit features microprocessor control, has natural frequency of less than 1 Hz, and incorporates automatic leveling mechanism. Using active feedback, it damps vibrations from 1.0–1,000 Hz. For vibrations above 1000 Hz, unit provides passive vibration control. Load capacities are 330–600 lb. |
 Stainless Steel Dampers resist corrosion.Greenheck Fan Corp.
Schofield, WI 54476 0410
Apr 15, 2004 Made completely of 316 stainless steel, Severe Environment Dampers are available in more than 20 models, providing fire life safety, control, and backdraft damper functions. Configurations include round, commercial, industrial, dynamic fire, smoke, and fire smoke dampers. Dampers are suited for paper mills, wastewater treatment plants, swimming pools, food processing plants, laboratories, and coastal buildings.
|
 Stainless Steel Damper suits corrosive environments.Continental Fan Mfg. Inc.
Buffalo, NY 14215
Nov 28, 2003 IRIS-S has interlocking AISI 316 stainless steel plates. Calibrated control lever allows blades to form adjustable aperture, permitting airflow regulation and measurement at one location. Damper measures differential pressure across pressure ports and refers to matching performance curve to determine airflow. Offered in 10 sizes from 4–32 in. with capacities to 20,000 cfm, it has neoprene gasket for airtight mounting. |
 Thermal Disk Link is reusable and re-settable.Lloyd Industries Inc.
Montgomeryville, PA 18936
Sep 10, 2003
LloydStat(TM) works with smoke/fire damper equipment to prevent ductwork damage via controlled closing mechanism. It closes and locks damper upon smoke detection, fire conditions, or power failure via actuator closure spring. Unit operates using electric bi-metal disc sensor thermostat that interrupts power to actuator. Once activated, spring return closes and locks damper within 10-15 sec. Once unit cools below sensor set point, product returns damper to open position.
|
 Motorized Damper handles air flows from 15–4,000 cfm.Continental Fan Mfg. Inc.
Buffalo, NY 14215
Sep 03, 2003 With IRIS-M motorized damper, minimum and maximum airflows are measured within ±5% by using product's pressure port and altered by means of actuator adjustment screws. Unit varies airflow in response to 0–10 Vdc or 4–20 mA signal to control temperature, humidity, or ventilation rate. External switch fully retracts damper for duct cleaning. Made from galvanized steel with neoprene seals, 6 sizes are offered to fit ducts from 4–12 in. dia. |
 Horizontal Machine Supports prevent walking and stop sway.AirLoc Products
Franklin, MA 02038
Jul 07, 2003 AirLoc Horizontal Wedgmount® Machine Supports offer integral damping and cushioning capabilities that dissipate up to 90% of horizontal load forces. Available with different mounting brackets, hardware, and vibration control pads, products can be adapted to customer requirements for machines and presses up to 3,000 tons or more. Installations include 4 individual supports offered in sizes that can withstand horizontal load forces from 5,000–250,000 lb. |
 Vibration Control System damps vibrations from 1.0–1000 Hz.Kinetic Systems, Inc.
Boston, MA 02131
Jun 17, 2003 Portable, tabletop Series 8000 uses active feedback to achieve high levels of vibration isolation for high-resolution instruments. It dynamically isolates all 6 possible translational and rotational modes of vibration with low natural frequency of 0.7 Hz. Microprocessor-controlled, automatic leveling mechanism rapidly adjusts to different loads up to 330 lb without user intervention. Isolation begins at 1.0 Hz and increases rapidly to 40 dB at 10 Hz. |
 Damper Drive Module suits industrial applications.Kinetrol USA, Inc.
Addison, TX 75248 2415
Dec 10, 2002 Module, compatible with all damper types, includes integral manual override and modulating or on/off control with failure mode options. Suitable for new installations or replacing existing electric/pneumatic drives, unit provides accurate air/gas flow control to burners, heaters, boilers, and turbine systems in power plants, refineries, and additional industrial applications. |
(Showing headlines 21 - 33) 1 2
|
|
|