HVAC
(Showing headlines 1981 - 2000) << 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105
|
 Portable Collector provides 382 sq ft of media.Air Quality Engineering, Inc.
Minneapolis, MN 55428
Apr 19, 2002 Rated at 1000 CFM, PortaAir(TM) has 1 1/2 HP motor and backward inclined fan that generates high suction at intake hood, even with dirty filters. Unit collects airborne contaminants with integral 11 ft, 8 in. dia, 360 deg rotating, externally supported arm, and deposits it in 2 pleated cartridge filters rated at 99.8% efficiency. Collector has 16 ga welded galvanized steel body; two 8 in. semi-pneumatic wheels in rear, and 2 swivel casters. |
 Vacuum offers 99.997% filtration efficiency.Nederman, Inc.
Westland, MI 48185
Apr 19, 2002 P300 portable dust extraction unit has manual reverse pulse filter cleaning system with filter life of 6,000 to 8,000 hr. It includes automatic start/stop for pneumatic tools, noise reducer, adjustable handle, and 4 wheels. Unit operates on 110 to 120 V and is suitable for cleaning workshops, on-tool extraction of grinding and sanding dust, and on-torch welding fume extraction. |
Duct Systems are made of CPVC.Harvel Plastics, Inc.
Easton, PA 18044 0757
Apr 19, 2002 Corzan(R) CPVC duct systems exhaust volatile fumes and exhibit resistance to chemical attack. Manufactured in pipe sizes from 6 to 24 in. diameters, ducting offers working temperature of 200 deg F and fire resistant properties. It can be connected with fume scrubbers or other emission control equipment. Applications include pulp and paper, metals finishing, water and wastewater treatment, electronics, and chemical processing. |
 HVAC Bypass System removes drive from circuit.Saftronics, Inc.
Fort Myers, FL 33905
Apr 18, 2002 FPC5010S Smart Bypass monitors drive load and speed, and automatically transfers motor from VFD control to across-the-line at full speed. Removing drive from circuit improves efficiency of system by as much as 5%. It also improves harmonic distortion at full load by removing drive from circuit when harmonic content is greatest. Controller continues to monitor demand and, when requirements are reduced, transfers motor back to drive control.
|
 Air Compressor can be hand carried.Mi-T-M Corporation
Peosta, IA 52068
Apr 18, 2002
Portable AC1-HE02-05M has 2.0 hp 120 V electric engine, single stage compressor, and thermal overload motor protection. Twin tank is powder coated and has 5 gal capacity, drain valves, pressure release valve, and quick connect fittings. Rubber handles provide better grip. Compact design allows for easy transportation to any job site.
|
 Cabinet Cooling Fan generates high pressure.Comair Rotron
San Diego, CA 92154
Apr 18, 2002 Mixed Flow DC fan combines characteristics of fans and blowers to deliver 375 CFM at static pressure of 1.5 in. of water, making it suitable for telecommunication applications and for cooling computer cabinets and racks. Optional EnviroShield(TM) coating prevents degradation caused by harsh environmental conditions, moisture and salt. UL-approved, polarity-protected fan meets UL 94V-0 flammability rating. Operating temperature is –10 to 70 deg C. |
 Enclosure Air Conditioner works indoors or out.Kooltronic Inc.
Pennington, NJ 08534
Apr 17, 2002 Advantage Series RP55 cools, dehumidifies, then recirculates clean, cooled air through enclosure. Made of galvanized steel with textured baked powder finish, it is available in capacities from 18,000 to 22,000 Btu/hr. UL/CUL-recognized air conditioner has NEMA 12 and 3R enclosure ratings, digital temperature display, built-in condensate evaporator, thermostatic low-temperature control, EMI/RFI suppressor, and line of accessories.
|
 Air Humidifier fits into existing air handling units.Munters Corporation / Systems Division
Fort Myers, FL 33911
Apr 16, 2002 HUMIdek(R) humidifies through direct evaporation of water into air. Through its use of solenoid/flow valves, system delivers precise humidity control. Evaporation media surface also acts as sound attenuator. HUMIdek comes with 4 in. of UL 900 flame rated GLASdek media, which meets NFPA 90A codes. |
 Dust Collector keeps personnel out.Dynamic Air Inc.
Saint Paul, MN 55110 5128
Apr 16, 2002 Modu-Kleen(R) downdraft dust collector contains fugitive dust. Air enters at top of collector housing and flows downward to cartridge filters, improving filtering process and material-to-air ratio. Cartridge filters are horizontal, requiring little floor space and making filter removal easier. Personnel never have to enter filter housing for maintenance or cartridge filter removal. Large door allows personnel to inspect each cartridge when required. |
Fan is quiet enough for libraries.Greenheck Fan Corp.
Schofield, WI 54476 0410
Apr 16, 2002 QEI mixed flow fan comes with Sound Vault Housing that is lined with 2 in. of sound-attenuating insulation, integral isolators, and flexible connections to lock-in radiated sound and minimize vibration transmission. Housing reduces radiated sound levels by more than 50%, making it suitable for fans located adjacent to occupied workspace. Applications include office buildings, libraries, or educational facilities.
|
 Cabinet Cooler minimizes air use.EXAIR Corporation
Cincinnati, OH 45249-1621
Apr 12, 2002
ETC electronic temperature control keeps electrical enclosures cool. It maintains temperature within +/- 1 deg F of dial setting and minimizes compressed air use by permitting higher temperature setting of thermostat. When selected temperature is exceeded, cooler circulates 20 deg F air through enclosure. Cooling capacities up to 2800 Btu/hr. are available. Applications include cooling CNC panels, computer cabinets, programmable controllers, and drives.
|
 Air Compressor offers hand-carry portability.Mi-T-M Corporation
Peosta, IA 52068
Apr 11, 2002
Gasoline-powered AC1-HR45-05M utilizes 4.5 HP Robin OHC engine and features single-stage compressor, powder-coated 5 gal capacity tank, drain valves, and pressure-release valve. Head and crankcase are aluminum, and cylinder is cast iron. Motor and pump have protective housing. Unit includes 2-handled system for one- or two-man transporting.
|
 Fume Extraction Arm suits heavy duty use.Nederman, Inc.
Westland, MI 48185
Apr 11, 2002 NEX HD Arm is made with aluminum hood, 8 in. dia high temperature hose, and external support system. It is designed for heavy duty welding and plasma cutting operations where extreme heat resistance is necessary. Horizontally articulated swivel, horizontally pivoted boom, and vertically pivoted supporting arm provide mobility over entire working range of arm. Arm is available in lengths of 7, 10, 13, and 16.5 ft. |
 Air Filter saves space, reduces energy.Camfil Farr
Riverdale, NJ 07457
Apr 10, 2002 Ultrasolve(R) minipleat air filter is only 4 in. deep, saving air handler component and inventory space, and its low pressure drop reduces energy consumption. Filter is available in three efficiencies: MERV 11, 13 and 14 based on ASHRAE 52.2. All use polypropylene media with high strength, low resistance to airflow, and moisture resistance in high humidity applications. Applications include commercial, food processing, electronics, and other facilities.
|
 Coolers/Condensers feature copper coil construction.Recold
Brea, CA 92821-4899
Apr 10, 2002 M Series closed circuit Fluid Coolers and Evaporative Condensers, with copper coil technology, perform in harsh conditions. Prop fan, constructed of glass reinforced polypropylene, pulls air through top of unit instead of pushing air out. Condensers have nominal capacity of 50 to 340 tons while Fluid Coolers range from 19 to 130 tons and can accept water temperatures up to 150 deg F. All units come with 304 stainless steel sump pans and access doors. |
 Air Compressor connects to direct gear motor.Sullivan-Palatek, Inc.
Claremont, NH 03743
Apr 10, 2002 30-40-50 DG industrial electric-driven rotary screw air compressor is available in 30-50 hp models that are directly coupled to motor for positive alignment. It is equipped with air pressure gauge, hour meter, discharge temperature gauge, oil filter, and separator element differential gauges. Discharge pipe is steel braided flexible pipe. Large air intake has oversize multi-stage dry type replaceable element.
|
 Air Lifts use normal shop compressed air.AeroGo, Inc.
Seattle, WA 98188 3909
Apr 09, 2002 Aero-Pallets and Aero-Planks utilize Air-Film technology, which allows omni-directional movement and positioning in tight spaces on loads from 500 lbs to 5,000 tons without causing floor damage. Steering and positioning control is provided via products' Guide Wheel designs. Flat deck (as thin as 2 in. height off of ground) slips under loads and provides its own lift with shop compressed air. |
 Aluminum Saddle mounts cold plates to electronic boards.Lytron, Inc.
Woburn, MA 01801 1039
Apr 08, 2002 Aluminum Saddle has through or tapped holes for securing company's CP-20 Extended Surface cold plates to electronic boards. It applies consistent force across cold plate, ensuring good thermal connection. All-aluminum cold plates consist of connector tubes welded to micro-channel aluminum extrusion. They can be used with EGW, refrigerant, Fluorinert(R), and other fluids to remove heat from high heat load discrete components. |
 Air Data Boom includes total air temperature sensor.SpaceAge Control, Inc.
Palmdale, CA 93550
Apr 08, 2002 Model 100900 heated, 4-vane air data boom provides supersonic data collection of angle of attack, angle of sideslip, static pressure, total (pitot) pressure, and total air temperature. Based on heated probe wind-tunnel tested to Mach 1.3, boom is constructed from machined aluminum, stainless steel, and copper alloys. Probe is 28 Vdc powered at 145 A, and meets requirements of MIL-T-5420B and SAE AS 393. |
 Ultrasonic Flowmeter features IP65 construction.TTI, Inc.
Williston, VT 05495
Apr 08, 2002 Time Delta M flowmeter offers menu-driven programming via built-in keypad, 4-20mA rating, pulse frequency, totalizer, and alarm outputs. Unit has multiple language support, enabling users to program and view data in their native language. Clamp-on sensors eliminate concerns associated with ultrapure or toxic fluids and contamination. |
(Showing headlines 1981 - 2000) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105
|
|
|