|
|
|
|
|
HVAC
(Showing headlines 121 - 140) << 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 ...
|
 DIN Enabled Temperature Sensors support tool-free changeout.Omega Engineering, Inc.
Stamford, CT 06907
Aug 09, 2011
With vibration-resistant construction and IP67 rating, M12 Thermocouple and Pt100 sensors are available with stainless steel or Inconel sheath in both 3 and 6 mm dia and come in standard lengths of 200, 500, 750, 1,000, and 1,500 mm. Termination is achieved via polarized M12 connector with hand-tightened knurled nut. No tools are required for sensor change, minimizing downtime, and available process fittings include BSP, NPT, and metric mounting threads.
|
Two-Color IR Temperature Sensors feature 80 µsec response.Process Sensors Corp
Milford, MA 01757
Aug 05, 2011
Able to capture 12,500 measurements/sec, Metis HQ11/HQ22 self-contained, non-contact, IR thermometers have 350 to 2,500°C temperature span and 0.5-23 mm dia target spot sizes. Products utilize focusable optics or focusable lens fiber optics and can also be used as single wavelength pyrometers. Intended for use where short-duration phenomena need to be monitored, thermometers offer switchable single wavelength mode as well as choice of 3 methods of optical alignment and focusing onto target.
|
 Axial Fans withstand rigors of marine environment.Delta T Systems
Riviera Beach, FL 33404
Aug 03, 2011
Designed to meet boat builders' needs, Redneck Axial Fans include Economy line in sizes from 12-24 in. with plastic housing, as well as Standard line ranging from 12-48 in. with steel housing. Hubs are secured directly to motor shaft for safety and fan blades are factory-balanced for smooth operation. Named for red bolt seating ring around housing flange, fans have airfoil blade shape that optimizes air flow while providing quiet performance.
|
Cooling Fan Control IC optimizes rotation speed.Melexis Inc.
Concord, NH 03301
Aug 02, 2011
Able to control single-coil brushless cooling fan speed using PWM or analog signals, Hall effect-based Model MLX90287 is suited for desktop computers, gaming consoles, and LED automotive headlights. Unit operates from supply voltage of 4.5-16 V and within ambient temperatures from -40 to 150°C. With integrated power stage, IC can drive fans rated up to 550 mA. Device directly accepts, without any external circuitry, PWM frequency range of 100 Hz to 100 kHz.
|
 IR Temperature Sensors integrate network communication options.Raytek Corporation
Santa Cruz, CA 95061 1820
Jul 28, 2011
Combining communication module and IP65 stainless steel sensing head, MI3 Series is compatible with Modbus and Profibus network protocols for applications requiring digital communication with field devices. Multichannel thermometers, with response times as fast as 20 msec, offer choice of sensing head temperature ranges and spectral responses, USB 2.0 digital interface, and multiple sensing head interface. Latter supports up to 8 individually addressable heads per communication box.
|
 Retrofit Bath Fan Kit optimizes ventilation.Continental Fan Mfg. Inc.
Buffalo, NY 14215
Jul 27, 2011
Based on ENERGY STAR® qualified AXC-ES in-line duct fan operating at 147 cfm, RBFK Retrofit Bath Fan Kit includes all necessary hardware for conversion and installation. Remotely mounted fan, offering quiet operation, helps minimize moisture, mold, and mildew. Kit uses existing grille and fan housings and does not require ceiling repairs.
|
Conductive Dust Collector Filter provides static dissipation.Camfil Farr Air Pollution Control
Jonesboro, AR 72401
Jul 26, 2011
Utilizing carbon-impregnated media designed for use where conveyed dusts generate static charges that require dissipation, HemiPleat® Filter delivers average filtration efficiency of 99.99% on particles 0.5 microns and larger by weight. Filter combines conductive properties with open-pleat design that optimizes airflow through cartridge. With media resistance levels less than 1 MW/sq (106), HemiPleat® filter meets NFPA and ATEX requirements.
|
 Compact Blown Film Air Coolers range from 600-9,000 cfm.Mokon
Buffalo, NY 14207
Jul 25, 2011
BFC Series promotes blown film productivity, especially in warmer climates or environments where ambient air temperatures rise during summer, by eliminating production variables in air ring supply. Air inlet diffuser creates uniform airflow across cooling coil and decreases delta temperature approach, and insulated leaving air chamber reduces condensation while providing coldest air possible to air ring. Powder-coated, heavy-gauge steel cabinet is designed for 35 in. static pressure.
|
 Multifunction IAQ Monitor accommodates multiple applications.E Instruments International LLC
Langhorne, PA 19047
Jul 15, 2011
Supplied in ABS shock-proof housing with 2-line, ICE BLUE LCD, AQ200 features CO2 and CO sensors with respective ranges of 0-5,000 ppm and 0-1,000 ppm and resolution of 1 ppm. Monitor can also detect ambient temperature from -4 to 176°F, Delta T, atmospheric air pressure, and humidity. Protected to IP54 standards, hand-held unit comes with memory and software and offers Min/Max/Hold functions as well as unit selection and 8,000 data memory points.
|
 Liquid Flow Sensor serves low-volume dosing applications.Sensirion Inc.
Westlake Village, CA 91361
Jul 11, 2011
Able to detect flow rates below 120 mL/min for hydrocarbon-based liquids, SLQ-QT105 offers ~40 msec measurement response time and sensitivity for flow rates down to 3 mL/min. Detection of air bubbles in µL range is also possible, and all wetted materials are made from PTFE or quartz glass. Flow is measured without moving parts and non-invasively through wall of straight flow path. Features include fittings for 4 x 3 mm PFA tubing, digital interface, and RS485 communication.
|
 CPU Cooling Units promote efficient, stable operation.GlacialTech Inc.
Taipei Taiwan
Jul 06, 2011
Intended for 65 W AMD CPUs with FM1/AM2/AM2+/AM3 sockets, Igloo A200 Series includes 3 models made of aluminum alloy that measure 68 x 76 x 42.3 mm and weigh 165 g. Included 12 Vdc fan measures 70 x 70 x 15 mm and operates, depending on model, up to 2,600, 3,200 rpm, or 1,200 PWM (±300 rpm) to 3,600 ±10%. Respectively, airflow values of 18.4, 22.4, and 27.6 ±10% cfm are achieved with noise ratings of 21, 26, and 34 dBA. In PWM version, fan speed increases with CPU load.
|
Temperature Sensor IC provides PWM output signal.Seiko Instruments GmbH
Neu-Isenburg Germany
Jul 06, 2011
Developed in CMOS technology, 1-wire Model S-5855A changes duty cycle of frequency, preset with single capacitor, according to ambient temperature. Temperature at which sensor will start to modulate its output signal is determined at time of order and may be selected from 40-80°C in 10°C increments. Housed in SNT-4A and SOT-23-5 packages with current consumption of 50 µA, IC is suited for over-temperature protection of LED lighting used in flat screen TVs and computer LCDs.
|
MEMs IR Temperature Sensor features integral compensation.Melexis Inc.
Concord, NH 03301
Jun 29, 2011
Suited for automotive, medical, industrial, and consumer applications, MLX90614 series incorporates compensation technology that minimizes error induced by fast temperature variations and/or thermal gradients. Models MLX90614ESF-DCH/-DCI integrate refractive silicon lens to achieve fields of view down to 5°, enabling measurement of small objects. Able to measure human body temperature with accuracy of 0.2°C, plug-and-play sensors are factory calibrated and occupy TO-39 footprint.
|
 Industrial Fans keep people cool and areas ventilated.Continental Fan Mfg. Inc.
Buffalo, NY 14215
Jun 28, 2011
Available in 24, 30, and 36 in. dia with capacities up to 20,500 cfm, APC Direct Drive Industrial Product and People Coolers feature all-welded steel construction and heavy-duty, non-tipping base. Adjustable drum housing encloses spark-resistant, cast aluminum axial impeller within front and rear guards. Portable products, designed to provide rapid cooling and spot ventilation, are available with 115/230/1/60 V or 230/460/3/60 V TEFC motor.
|
Pneumatic Slide Gates help conserve energy.Imperial Systems, Inc.
Jackson Center, PA 16133
Jun 27, 2011
Operating using compressed air cylinder, Heavy Duty Pneumatic Slide Gates are used to control air flow and conserve energy. Units are used to deliver positive shut-off to service machinery or to divert air. Available in 4-24 in. sizes, Heavy-Duty slide gates are constructed of 10 gauge body with 16 gauge blade. Extra-Heavy Duty models, made from 3/16 in. plate, are also available.
|
 Communicating Thermostat System features web-based dashboard.Jackson Systems LLC
Indianapolis, IN 46203
Jun 22, 2011
Utilizing web-based dashboard for programming, monitoring and control, WEB Comfort(TM) enables multiple thermostats to be wirelessly networked throughout building or home. System provides individual temperature control coupled with intelligent energy management. Since thermostat is Internet-enabled, it can be accessed from anywhere in world via standard web browser.
|
 Stainless Steel Water Coolers support welding and plasma cutting.Weldcraft
Appleton, WI 54911
Jun 17, 2011
Available in 115/230 V versions, Models 2500SS and 2502SS have 2 gal reservoir, while Models 3500SS and 3502SS have 3 gal reservoir, and Models 6500SS and 6502SS include 6 gal reservoir. Closed-loop design with radiator recirculates coolant through fan-cooled heat exchanger to prevent system from overheating. Positive vane-style displacement pumps provide consistent coolant flow and pressure ratings, while thermally protected 1/3 hp motor provides additional protection against overheating.
|
Dust Collectors feature HEPA safety monitoring filter.Camfil Farr Air Pollution Control
Jonesboro, AR 72401
Jun 17, 2011
Gold Series® Cartridge Dust Collectors use optional HEPA safety monitoring filter to prevent collected dust from re-entering workspace in event of leak in primary filtering system. Each module incorporates 2 HEPA filters capable of handling 2,500 cfm of air per filter and rated to remove 99.97% of airborne particles 0.3 micron and larger. Unlike after-filters that are installed downstream of fan with filter at positive pressure, Gold Series' design maintains after-filter at negative pressure.
|
 Hot Water Boiler Temperature Probe has integral connector.Measurement Specialties, Inc.
Hampton, VA 23666
Jun 16, 2011
Operating over -40 to +125°C range, RoHS-compliant Boiler Probe with Integrated Connector contains NTC thermistor soldered to 2.5 mm connector. Brass housing provides British Standard Pipe Fitting (1/8 BSPF) to facilitate installation and replacement, and optional threads are available for custom designs. Typical resistance is 10,000 Ohms at 25°C, and ±1°C tolerance is held over 25 to 85°C range. Users can expect beta value of 3976K (25/85), with variance of ±1%.
|
Dust Suppression System reduces health risks for miners.Quaker Chemical Corporation
Conshohocken, PA 19428
Jun 16, 2011
Comprised of wetting agents that accelerate water penetration in areas where dust poses hazard, DUSTGRIP(TM) TURBO reduces total water volume consumed for dust suppression purposes. It mixes with water and can be used with mine's existing equipment; no post-application rinsing of equipment is needed. Repeated applications have cumulative effect, maintaining subsoil moisture content for extended periods depending on soil types, traffic, and weather conditions.
|
(Showing headlines 121 - 140) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105
|
|
|