|
|
|
|
|
HVAC
(Showing headlines 1181 - 1200) << 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 ...
|
 Modular Control System offers sample cycle time of 250 ms.RKC Instrument
South Bend, IN 46628
Aug 17, 2006
With 0.2% accuracy, DIN rail mount SRZ Control System provides selectable position proportional control, cascade control, as well as heat only and heat/cool control. True universal input includes 10 thermocouple types, RTD, voltage, or current. Single module may provide up to 4 channels of heat only or 2 heat/cool to which up to 16 modules may be connected. Alarm choices include loop break, heater break, and interlock. Communications are provided via serial Modbus RTU.
|
 Bulk Powder Cooling System provides zero emissions.Solex Thermal Science, Inc. (formerly Bulkflow Technologies, Inc.)
Calgary, AB T2Z3V6 Canada
Aug 16, 2006
Equipped with tube exchanger that minimizes thermal stress and accommodates thermal expansion, Bulk Powder Cooling System cools bulk solids with temperatures up to 1,832°F. Bulk powder flows via gravity over water-cooled tubes. Geometry of tubes is uniform with even temperatures throughout tube wall to avoid hot spots and high local stresses. Integrating with existing equipment, system helps prevent product attrition and caking.
|
 Dust Extraction Arm features external support system.Nederman, Inc.
Westland, MI 48185
Aug 16, 2006
Available in lengths of 7, 10, 14, and 16 ft, NEX MD is suited for medium to heavy-duty welding and dust extraction applications. External support system and 6¼ in. diameter hose provide high airflow and low pressure drop. Ball joint suspension, combined with paralleograph construction, enables precise maneuverability of hood and arm, and protects external mechanism from dust and grit build up.
|
 Cleanroom Plenum Sections offer application flexibility.Clean Air Products Clean Air Systems Div.
Minneapolis, MN 55445 1828
Aug 15, 2006
Available in various configurations, Series 150 Vertical Flow Plenum Sections create modular systems that meet cleanroom application needs. Full ceiling, HEPA filter plenum sections provide filtered laminar flow air to clean areas. Series 151 have blowers on end and freestanding 551 series have legs added. Both can be building suspended with or without curtains. Units with blowers on top are Series 152, or freestanding Series 552 with legs added.
|
Fuel Cell Humidifier utilizes Nafion®-free material.Ener1, Inc.
Ft. Lauderdale, FL 33309
Aug 15, 2006
Designed for proton exchange membrane (PEM) fuel cell systems, solid-state EnerFuel EFH-100 series utilizes hollow fiber material designed to optimize overall durability. Product delivers optimal humidification irrespective of flow rates and is vibration-tolerant. Units with Air-to-Air and Water-to-Air modes of operation are available.
|
Desiccant Dehumidifier features weatherproof design.Bry-Air Inc.
Sunbury, OH 43074
Aug 11, 2006
Certified for outdoor use, MiniPAC® is ETL listed and available in ranges from 100-600 cfm with 480/3/60 voltage. It can be installed as stand-alone unit or attached to any existing HVAC system. Unit is suited for small facilities in need of humidity control, including restaurants, homes, and labs. Pre- and post-cooling is optional.
|
Additive offers solution to metalworking fluid mist.Lubrizol Corp.
Wickliffe, OH 44092 2298
Aug 11, 2006
Based on active polymer technology, ADDCO® LoMist D reduces mist from coolant used in metalworking applications by up to 60%. After treatment, fewer aerosols form, preventing fluid from breaking up and floating through air. Product has no adverse impact on production, parts quality, microfinish, or wastewater treatment. ADDCO LoMist D can be used in most soluble oils, semi-synthetic fluids, and synthetic fluids.
|
 Rotary Lobe Blowers range from 5-200 hp.Kaeser Compressors, Inc.
Fredericksburg, VA 22404
Aug 10, 2006
Featuring tri-lobe Omega Plus profile, Com-paK Plus Blowers are equipped with generously sized motor, silencers, instrumentation, and valves. All maintenance points are accessible through canopy on front, and all power and process connections are at rear, allowing multiple units to be mounted side by side. Standard sound dampening enclosure lowers typical noise levels to 75 dB(A) or less, while integral ventilation fan provides cooling, even under extreme load conditions.
|
 Iris Dampers control temperature/humidity/ventilation rate.Continental Fan Mfg. Inc.
Buffalo, NY 14215
Aug 09, 2006
Delivering air balancing accuracy to ±5%, Iris Damper permits airflow to be adjusted and measured at one location. It uses interlocking steel plates and calibrated control lever to form adjustable aperture. By measuring differential pressure across pressure ports and referring to matching performance curve, product enables airflow to be precisely determined. Ten sizes are available, from 4-32 in. dia, with capacities from 15-20,000 cfm.
|
 Pancake Filters provide efficiency of 99.97%.North Safety Products, Inc.
Cranston, RI 02920
Aug 09, 2006
Pancake Series Filters provide odor relief from nuisance levels of organic vapors, acid gases, and ozone. Designed to fit under welding helmets and face shields, Model P100 protects against dusts, mists, and fumes. Unit can convert into pre-filter with adaptor for APR cartridges. Applications include welding, metal pouring, grinding and sanding, mineral processing, coating applications, brazing and soldering, pharmaceutical manufacturing, and foundries.
|
 Downdraft Tables manage ultra-fine dust applications.Aget Mfg. Company
Adrian, MI 49221
Aug 09, 2006
Consisting of Downdraft Table with backdraft booth, dual-stage air purifying workstations provide particulate and contaminate capture, removal, and disposal. Single-hopper models range from 36-48 in. wide and 30-48 in. deep, while dual hopper models are 60-96 in. wide and 36-48 in. deep. Overhead exhaust outlets are sized to application. Adjustable baffles within slotted hood system provide means to control air flow and volume and to balance air movement between systems.
|
 Temperature Sensing Solution has DIN Form B-compliant case.Precision Linear Systems, Inc.
Cupertino, CA 95014
Aug 01, 2006
Model DF01 is comprised of solid-state temperature sensor and 4-20 mA loop-powered transmitter manufactured on same flexible circuit substrate and connected together by traces on flex. Sensor and transmitter are calibrated and set over their full operating temperature ranges at test, -50 to +150°C and -25 to +75°C respectively, which lends to model-dependent system accuracies of ±0.3, 0.5, or 0.8°C. Sensor is ready to be inserted and sealed into sensor tube.
|
 DC Ball Bearing Fans deliver up to 17.47 cfm.Air Performance Tech
Fremont, CA 94588
Aug 01, 2006
Designed for 1U applications, Series AP4028 measures 40 x 28 mm and delivers up to 17.47 cfm of airflow with unregulated 12 or 24 V input. Fans draw max power of 7.2 W and operate with max noise level of less than 45.7 dB. All models are available with optional 3rd wire tachometer or locked rotor signals. Utilizing dual ball bearing technology, fans gain more than 50,000 hours MTBF in typical 0-40°C environment.
|
 Sensor and Transmitter target HVAC applications.Precision Linear Systems, Inc.
Cupertino, CA 95014
Jul 31, 2006
Combining solid-state temperature sensor and 4-20 mA transmitter, Model MF01 provides system accuracy of ±0.5 and 1°F. Sensor is ready to be inserted and sealed into sensor tube. Injection molded miniature case holds transmitter and output terminals and can be mounted in standard HVAC wall mount or duct probes. Both sensor and transmitter are calibrated and set over their full operating temperature ranges at test.
|
Temperature Sensors feature user-programmable display.Madison Company
Branford, CT 06405
Jul 31, 2006
Madison-Omni® compact RTD temperature sensors are comprised of Madison-Omni® integrated display/control unit and platinum RTD temperature sensor tip. User-programmable display interface allows for setting of 2 alarm points and offers uniform readout for several sensor monitoring options. Available in 12 configurations, sensors offer various temperature ranges, depending on model.
|
Refrigerant Dehydrator operates continuously.Redi/Controls, Inc.
Greenwood, IN 46143 1406
Jul 28, 2006
Able to process 4,200 lb of refrigerant per week, Model CD-120 removes moisture, acid, sludge, and particulates from any flooded evaporator AC/R refrigeration systems. Totally automatic unit features 4 filter cores and uses only gravity, heat, and pressure differential to operate. For installation, dehydrator requires 120 Vac power supply and two 3/8 in. connections. Refrigerant charge does not have to be pulled to install.
|
Duct Liner includes recycled content.Johns Manville
Denver, CO 80202
Jul 26, 2006
Featuring fortified glass mat airstream surface, LinaTex(TM) Textile Fiber Duct Liner resists fiber erosion when exposed to airstream in commercial duct systems. Flexible, high-density mat will also resist pull-through when pinning, minimizing need for repairs. To satisfy demand for products that support green building programs, LinaTex(TM) contains up to 75% of pre-consumer and post-industrial content.
|
 Heated Floor Mat eliminates snow, ice, and water worries.Martinson-Nicholls, Inc.
Willoughby, OH 44094
Jul 24, 2006
Used indoors or outdoors, Warmer Winter Heated Floor Mat keeps commercial and industrial entranceways clear of snow, ice, and tracked-in water throughout winter on 24/7 basis. Non-slip, low-profile surface ensures safe traversal on building walkways, loading docks, and ramps. Offered in standard and custom-fitted sizes, self-drying mat employs 24 V, self-regulating, 25 W/ft² heat output and features corner grommets.
|
 Radiation Dampers connect to ductwork at various angles.Lloyd Industries Inc.
Montgomeryville, PA 18936
Jul 19, 2006
Fiberglass plenum box with ceiling radiation damper is designed as 1 and 1.5 in. thick rigid ductboard with registers/grilles or drop duct applications. Available in I, J, and K models with standard sizes ranging from 8 x 4 to 16 x 16. J and K models are offered in either R4.2 or R6.0 insulation thickness. All ceiling radiation dampers hold ARL approval for 1 hr fire resistance rating for use in UL Fire Resistance Rated Wood Truss Assemblies.
|
Dust Collector Filters have MERV 15 efficiency rating.Camfil Farr Air Pollution Control
Jonesboro, AR 72401
Jul 17, 2006
Available in sizes to fit any cartridge collector, HemiPleat HE Filters provide efficiency of 99.999% on 0.5 micron particles and larger. Design holds pleats of filter open, making virtually all media surface available for filtration and allowing dust to eject from deep within pleats during pulse cleaning. Filters are suited for capture of toxic and other ultra-fine dusts, and for applications where process air is recirculated downstream of collector.
|
(Showing headlines 1181 - 1200) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105
|
|
|