Battery Impedance Tester determines condition, remaining life.

Press Release Summary:




Without taking batteries off line, BAT-500 simultaneously measures resistance to 40 W with accuracy of ±1% of reading ±10 digits and voltage to 40 V with accuracy of ±0.1% of reading ±6 digits. Comparator function with pass/warning/fail indication accelerates testing of batteries up to 500 Ah. There are 99 memory locations to store results, and RS232 interface enables data export to PC for trending/life cycle analysis. Solution comes with test probe, software, and RS232 cable.



Original Press Release:



Model: BAT-500 Battery Impedance Tester



Quick and accurate battery testing without taking the batteries off line. Comparator function with pass/fail indication speeds testing of batteries up to 500Ah. Typical applications include but are not limited to power back-up and UPS systems.

  • Tests battery Impedance to calculate its true life
  • Works with most batteries, compact storage batteries, alkaline and lead-acid up to 500Ah
  • Resistance measurement up to 40 ohms, and voltage up to 40V
  • Tests are performed without shutting down a battery
  • Simultaneously measure battery resistance and voltage
  • Comparator function to quickly access conditions as Pass,Warning, or Fail
  • 99 memory locations to store results with read function
  • Compact and lightweight
  • RS232 PC Interface to download testing results to a PC for trending/life cycle analysis
  • Instruction manual, Batteries, Test probe, Software, RS232 cable

    F E A T U R E S
    Battery Life: 7 hours approx
    Size: 250(L) x 100(W) x 45(H)mm (9.8 x 39.4 x 1.8 in)
    Weight: Approx. 500g (1.1 lb) including batteries
    Safety: N10140

    Instruction Manual: Yes

    Detailed Specs: Yes

    Hi-Resolution Image: Yes

    S P E C I F I C A T I O N S
    Battery Types Tested: Compact storage batteries, Alkaline, Nickel-Metal Hydride (NiMH), Nickel-Cadmium (NiCd), Lithium-ion (Li-ion) and lead-acid batteries
    Battery Capacity: 0 to 500AH
    Impedance Measurement Range: 40mW, 400mW, 4W, 40W
    Resolution: 10µW, 100µW, 1mW, 10mW
    Accuracy: ±(1%reading ±10digits)
    Open Circuit Voltage: 3.5Vpp max
    Measurement Current: 25mA approx., 2.5mA approx., 250µA approx., 25µA approx
    Measuring current Frequency: 1KHz ±10%
    Voltage Measurement Range: 4V, 40V
    Resolution: 1mV, 10mV
    Accuracy: ±(0.1% rdg ±6 digits)
    Data Memory: 500 data sets
    Continuous Data Memory: 9600 data sets (only use PC download)
  • All Topics