Electro-Chemical Devices, Inc.
Irvine, CA 92614
Share:
New UV-6 Analyzers Reduce Maintenance Time and Consumables Expense
Accurately measure the presence of ammonia, nitrate, COD, BOD or TOC via its spectroscopic sensor at a 254 nm wavelength. Features built-in spray cleaning system to keep light source and sensor cell free from algae growth and sticky particles to ensure accuracy. Available in 110-130 VAC or 220-240 VAC /30VA / 50-60Hz or 12-15 VDC /4A power supply options.
Read More »Optical Dissolved Oxygen Sensor provides years of service.
Employing fluorescence quenching sensing element that eliminates need for frequent calibration or membrane replacement, Triton DO80 continuously analyzes oxygen level, water temperature, and air pressure to calculate dissolved oxygen values. Max error is less than 2%, repeatability is Ã-
Read More »Dechlorination Analyzer requires no chemicals to monitor seawater.
Model DCA-23 monitors chlorine in seawater from 0.0-2.0 ppm. Unit measures pH from 0-14, temperature from 0-100Ã-
Read More »ClO2 Analyzer has panel-mounted, low-maintenance design.
Model CDA-22 Chlorine Dioxide Analyzer measures ClO2 in concentrations ranging from 0.05-20 ppm. System incorporates PTFE membrane amperometric ClO2 sensor with 32-212Ã-ºF operating temperature range, automated flow control device, and analyzer/controller mounted on PVC panel. Low-maintenance unit can run for up to 1 yr between electrolyte/membrane changes. Providing dual measurements and XY...
Read More »Chlorine Analyzer eliminates pH sampling systems, reagents.
Featuring built-in pH compensation (4-12) and plug-and-play design, TCA-22 is suited for testing drinking water, industrial cooling and rinse water, wastewater, or other fresh water samples containing 0-20 ppm chlorine. Amperometric sensor has 3-electrode design, which measures all chlorine species in water, combined chlorine and free chlorine. While counter electrode provides stable base...
Read More »Automated Blowdown System increases boiler efficiency.
Featuring intelligent controller design, Model 61 BBS modulates blowdown control valve to allow maximum level of dissolved solids, regardless of load conditions, in order to maximize boiler maintenance efficiency. Plug-and-play system has modular design that includes 316 SS sediment trap and sample cooler, temperature gauge, sample control valve, and safety relief valve. Its 4-20 mA output may be...
Read More »New UV-6 Analyzers Reduce Maintenance Time and Consumables Expense
Accurately measure the presence of ammonia, nitrate, COD, BOD or TOC via its spectroscopic sensor at a 254 nm wavelength. Features built-in spray cleaning system to keep light source and sensor cell free from algae growth and sticky particles to ensure accuracy. Available in 110-130 VAC or 220-240 VAC /30VA / 50-60Hz or 12-15 VDC /4A power supply options.
Read More »ECD Announces New Web Site With Online Store For Liquid Analytical Process Instrumentation
Electro-Chemical Devices (ECD) announces its new Web Site, featuring an Online Store with a powerful Select By Measurement Tool, which simplifies the task of choosing sensors, transmitters, analyzers and accessories for measuring pH, ORP, conductivity, resistivity and dozens of other industrial fluids. The new ECD liquid analytical process instrument Select by Measurement Tool allows site...
Read More »Optical Dissolved Oxygen Sensor provides years of service.
Employing fluorescence quenching sensing element that eliminates need for frequent calibration or membrane replacement, Triton DO80 continuously analyzes oxygen level, water temperature, and air pressure to calculate dissolved oxygen values. Max error is less than 2%, repeatability is Ã-
Read More »Dechlorination Analyzer requires no chemicals to monitor seawater.
Model DCA-23 monitors chlorine in seawater from 0.0-2.0 ppm. Unit measures pH from 0-14, temperature from 0-100Ã-
Read More »ECD 2010 CD Product Catalog Now Available
Irvine, CA - August, 18, 2010--Process and plant engineers in search of advanced industrial analytical instrumentation solutions will find the new ECD CD Catalog for 2010 from Electro-Chemical Devices, Inc., provides them with applications guidance and valuable installation tips for devices measuring pH, oxidation reduction potential (ORP), specific-ion (pION), conductivity and resistivity,...
Read More »ClO2 Analyzer has panel-mounted, low-maintenance design.
Model CDA-22 Chlorine Dioxide Analyzer measures ClO2 in concentrations ranging from 0.05-20 ppm. System incorporates PTFE membrane amperometric ClO2 sensor with 32-212Ã-ºF operating temperature range, automated flow control device, and analyzer/controller mounted on PVC panel. Low-maintenance unit can run for up to 1 yr between electrolyte/membrane changes. Providing dual measurements and XY...
Read More »Chlorine Analyzer eliminates pH sampling systems, reagents.
Featuring built-in pH compensation (4-12) and plug-and-play design, TCA-22 is suited for testing drinking water, industrial cooling and rinse water, wastewater, or other fresh water samples containing 0-20 ppm chlorine. Amperometric sensor has 3-electrode design, which measures all chlorine species in water, combined chlorine and free chlorine. While counter electrode provides stable base...
Read More »Automated Blowdown System increases boiler efficiency.
Featuring intelligent controller design, Model 61 BBS modulates blowdown control valve to allow maximum level of dissolved solids, regardless of load conditions, in order to maximize boiler maintenance efficiency. Plug-and-play system has modular design that includes 316 SS sediment trap and sample cooler, temperature gauge, sample control valve, and safety relief valve. Its 4-20 mA output may be...
Read More »