 Rate Indicator/Totalizer uses HART communications protocol.Hoffer Flow Controls, Inc.
Elizabeth City, NC 27909
Aug 27, 2008
Compatible with Hoffer turbine flowmeters and other frequency producing flowmeters, HRT1 rate and total indicator features 20-point linearization, scaled pulse output, and 4-20 mA loop powered analog output. HART® protocol allows communication with processor via software or handheld communicator, enabling settings adjustment and diagnostic checks. Other features include rate, total, and grand total display as well as 2 optional alarm outputs configurable for rate and total.
|
 Pulse Input Flow Indicators offer batch controller mode.Dwyer Instruments, Inc.
Michigan City, IN 46361 0373
Nov 27, 2006
Suited for any flow application involving pulse signal, FIP Series flow rate/totalizer/batch controllers accept pulse, open collector, TTL, or square wave inputs and provide power to drive sensor. Meters display flow rate and total on 7-segment LED display that provides up to 4½ digits of rate display and 6 digits of total display. They can be equipped with one 4-20 mA retransmission output and 2 relays, which can also be used for alarming or batch controlling.
|
 Flow Indicators suit analog signal applications.Dwyer Instruments, Inc.
Michigan City, IN 46361 0373
Nov 21, 2006
Accepting all standard process signals such as 4-20 mA, 1-5 V, and 0-5 V, Series FIV flow rate/totalizer/batch controllers feature 7-segement LED display that provides 4½ digits of flow rate and 6 digits of total. For applications requiring more than display of rate or total, meters can be equipped with 2 relays and 4-20 mA retransmission output. Relays can also be used for alarming based on flow rate or for batch controlling based on flow total.
|
 Hydraulic System Analyzer indicates flow and pressure.Lake Monitors, Inc., Division Of TASI
Milwaukee, WI 53215
Oct 03, 2005
Style K Hydraulic System Test Analyzer offers choice of aluminum constructed meters for pressures up to 3,000 psi or stainless steel meters for pressures up to 5,000 psi. Available for 3/8-1½ in. NPT or SAE port sizes, product is capable of handling operating temperatures up to 240ºF and flow rates to 150 gpm with ±2.5% of range accuracy.
|
 Visual Flow Indicators meet sterile-service needs.L.J. Star, Inc.
Twinsburg, OH 44087
Feb 25, 2005 Sterile Full View Flow Indicators provide operators with 360° view of process fluid. Installed in new systems or as retrofit component, units are designed for pressures up to 150 psig and come in 11 sizes with standard hygienic clamp connections or optional orbital weld connections. Providing internal transition between electropolished stainless steel heads, O-rings, and precision bore glass window, units can be cleaned-in-place, sterilized-in-place, and autoclaved. |
 Hydraulic Tester offers reverse flow capability to 50 gpm.Webster Instruments
Milwaukee, WI 53235
Jul 27, 2004 With working pressure to 6,000 psi, Series RFIK provides safe in-line testing of mobile or industrial hydraulic circuits. Reverse flow feature allows machine to be fully cycled during troubleshooting and prevents cylinder lock-up and pressure intensification. Flow rate is displayed on 2.5 in. dial, which imparts rate of change indication and accuracy better than 4% FSD. Housed in steel case, kit requires no batteries to measure flow, pressure, and temperature. |
 Sight Flow Indicator/Totalizer offers clear view of rotor.Dwyer Instruments, Inc.
Michigan City, IN 46361 0373
Nov 19, 2002 Constructed of clear Polysulfone, Series SFI-800 rotor-style flow indicator enables 360° viewing of rotor and is mountable in any orientation. Unit has pressure rating of 150 psi and temperature rating of 212°F. Optional A-711 output sensor has Vdc output, with pulsing for flow totalization and proportional frequency change for flow rate. Unit is constructed of FDA-approved wetted materials and rotor contains no magnets with which to attract ferrous materials. |
 Flow Indicator shows pulses with green LED.Oil-Rite Corporation
Manitowoc, WI 54221 1207
Jun 20, 2002 Sight-Riteâ„¢ flow indicator may be used for any lubrication or process equipment that carries pulse of fluid less than 0.012 cu in. Each pulse activates indicator light. Indicator body is epoxy and acetyl to resist chemicals and solvents, while internal mechanisms are stainless steel to resist rust and corrosion. Indicator detects flow for fluid viscosities from SAE 10W through 50W oils. Green LED is daylight visible and powered by button cell battery. |
 Flow Indicators suitable for sterile applications.L.J. Star, Inc.
Twinsburg, OH 44087
May 30, 2002 FDA compliant, 3-A approved stainless steel and borosilicate glass visual flow indicators can be mounted as section of hose or pipeline. They provide clear view of virtually any process fluid or powder. Indicators have non-trapping O-ring, electropolished contact surface, and armored housing to protect glass from impact damage and pipe stress. Pressure ratings range up to 150 psig. Indicators can be used in sterile, sanitary, or lab-scale processes.
|
 Indicators are actuated by single or dual bellow.Barton Instrument Systems, LLC
City Of Industry, CA 91749-1882
May 14, 2002 Indicators are used for measurement of differential pressure, flow rate, and liquid level. Dial sizes include 3, 3 1/2, 4 1/2, and 6 in. Pointer traverses 270 deg arc and is driven by precision-jeweled rotary movement that multiplies rotation of torque tube through gear and pinion to pointer. Zero/range adjustments can be made without removing scale plate or pointer. Certain models have NEMA 4/IP65 rating and pulsation damping. |
 Flow Indicator operates without maintenance.RCM Industries, Inc.
Concord, CA 94520 1214
Apr 11, 2002 Flo-Vu(TM) maintenance free sight flow indicator meets ANSI standards for severe service. Indicator styles include propeller, drip tube, flapper and plain. Indicator is available for 1/2 to 3 in. pipe sizes and comes with 5 year leak free guarantee.
|
 Flow Indicator uses microwave technology.Monitor Technologies, L.L.C.
Elburn, IL 60119-8048
Mar 12, 2002 Solids Flow Indicator (SFI) detects flow in solid material applications including gravity chutes and pneumatic pipelines. SFI offers analog output and non-contact/non-intrusive design. Housing is rated for Class II dust-ignition proof environments, and meets NEMA 4 water-tight and dust-tight classifications. Other features include built-in averaging adjustment and LED indicators. |