Advertisement
|
|
Fluid & Gas Flow Equipment ->
Other
Other
(Showing headlines 61 - 80) 1 2 3 4 5 6
|
 Solvent-Usage Monitor offers local and remote reporting.AW-Company
Franksville, WI 53126
Jun 21, 2004 Solvent Usage Monitoring System (SUM), provides central hub for recording and reporting total usage of up to 20 solvent flowmeters. Totals or rates can be viewed in GPM or LPM on integral, digital display or output to printer via serial port. Additionally, collected data may be viewed from remote location in HTML web-page format via TCP/IP Ethernet communication port. Data page displays totals from up to 20 flowmeters on one page. |
 Gas Filling Machine rapidly fills insulating glass units.TruSeal Technologies Inc.
Beachwood, OH 44122
Jun 11, 2004 Semiautomatic Quik-Dose™ fills insulating glass units with liquid gas such as argon or krypton for thermal and sound insulation in times as short as 3½ sec. Upon droplet’s contact with sill edge of vented IG unit, liquid boils into gaseous state, displacing lighter, moist air. Displaced air exits through top edge’s perimeter vent, while heavier gas fills from bottom-up with very little turbulence. |
 Gas Delivery System suits laser assist gas applications.CONCOA
Virginia Beach, VA 23454
Jun 07, 2004 Series 622 Delivery System has single-body design suited for start up of 12-packs or liquid cylinders. Dome-loaded seat enables system to transition into point-of-use regulator of bulk installation. Used for nitrogen and oxygen assist gases from either cryogenic or high-pressure supply, design utilizes integral pilot regulator with stainless diaphragm and brass bar stock body to maintain purity. Maximum inlet pressure ranges from 600–4,500 psig. |
 Ruby Orifice Assemblies come in quick connect style.Bird Precision
Waltham, MA 02454
Apr 30, 2004 Quick connect orifice assemblies, suited for medical gas, analytical, and pneumatic applications, are offered in sizes from .0004 in. and up with flow rates from less than .5 ccm dry air. Typical tube sizes are 1/16 and 1/8 in. and larger, and assemblies can also be supplied in metric sizes. Offered with various male threads and NPTs, quick connect fittings can be supplied with single or dual filtration from 5 microns and up. |
 Ruby Orifice Glands suit face seal applications.Bird Precision
Waltham, MA 02454
Apr 30, 2004 Precision micron orifices, available in sizes 7.5 microns and up, are true, wire lapped, sharp edged orifices with uniform Cd values. Products yield accurate, repeatable flow, and orifice sizes can be laser etched. Ruby is chemically inert and wear-resistant. Orifice sizes yield flows from less than .5 ccm dry air and handle gas and liquid applications. Other uses include semiconductor, biochem, and laboratory applications. |
 Flow Conditioner eliminates asymmetrical flow profiles.Vortab Company
San Marcos, CA 92069
Mar 31, 2004 VOREL™ 90° Elbow Flow Conditioner optimizes pump performance by eliminating flow anomalies such as process media swirl associated with unconditioned, standard elbows. Flow stream enters pump in uniform and equally distributed pattern. Anti-swirl and inclined vortex-generating profile correction tabs, projecting from inside pipe surface, generate vortices that accelerate and amplify natural pipe effects to create uniform, non-swirling, symmetrical flow profile. |
 Toilet Retrofit System provides touchless flushing.Sloan Valve Co.
Franklin Park, IL 60131
Mar 18, 2004 Alkaline battery-operated Intelli-Flush™ retrofit for FLUSHMATE® pressure-assist toilet systems enables touchless, sensor operation that eliminates need for physical contact. Retrofit ensures clean, odor-free, and presentable appearance. Motor and cam gear technology actuates flushing mechanism, and IR Object Lock Technology controls flushing. Override button replaces flush handle, and white or chrome sensor trim is available. |
 Air Preparation Units withstand harsh environments.Festo Corp.
Hauppauge, NY 11788
Mar 10, 2004
Available in 3 body sizes, D-Series Air Preparation Units feature optimized internal flow paths that enable flow capacities from 24-406 scfm, depending on style and size. Products are offered in inch and metric series with port sizes from 1/8-1 in. NPT and G 1/8-1 ISO. Made of zinc and aluminum, die-cast units incorporate polycarbonate filter bowels and metal bowl guards. Filtration levels are 40, 5, 1, and 0.01 µm.
|
 Vent Panels minimize damage caused by expanding gases.ZOOK Enterprises, LLC
Chagrin Falls, OH 44022 0419
Jan 23, 2004 Explosion Protection Vent Panels protect systems and personnel in areas where dust particles from coal, wood, plastics, metal, or other products are present and may increase risk of explosion. Panels come in square, rectangular, or round configurations, and in flat or domed designs, as well as single-hinge or segmented types. They mount into standard angle frames and have burst ratings of 0.50–8.00 psi. |
 Flushing System aids with refrigerant recovery.PumpWorks, Inc.
Minneapolis, MN 55441
Jan 13, 2004 The BOSS™ Burn Out System Solution connects when flushing refrigerant from burned out systems. It features custom strainer for clean refrigerant flow, 3-way isolation valve, sight glass to visually verify complete recovery, and vacuum indicator light. No gauges or bags are required, and leakage is reduced or eliminated. Product is also available in kit form with PT GRIPPER quick connect tools for positive seal line connections. |
 Data Logging System simplifies compressed-air surveys.Logic Beach, Inc.
La Mesa, CA 91942
Dec 05, 2003 Model HLP-10 HyperLogger™ PowerPlus™ Data Logging System monitors and records air-compressor power data combined with pressure, mass air flow, and other compressor operating parameters. Power Sensing Harness transmits data via low-power isolated serial link, allowing HLP-10 to be located at safe distance from high-voltage connections. Self-contained system simplifies calculation of compressor efficiency by analyzing power consumption along with compressor output. |
 Flow Conditioner guards analyzers from liquid damage.Welker Engineering Co.
Sugarland, TX 77478
Oct 14, 2003 Able to remove liquids and particulates during gas sampling operations, stainless steel Guardian combines Automatic Liquid Shut-Off and Liquid Eliminator. Gas sample enters concavity where free liquids and aerosols are flushed through bottom and drained off, while conditioned gas flows through membrane separator to analyzer. Compact unit measures 2¼ x 4½ in., and installs into chromatograph, calorimeter, moisture analyzer and stack sampling systems. |
 Sound Enclosure decreases mechanical and vibration noise.Stoddard Silencers, Inc.
Grayslake, IL 60030
Aug 13, 2003 Model PSE Package Standard Enclosure provides as much as 15–10 dbA attenuation and exceeds OSHA noise regulation requirements for silencers. It includes cooling fan, air inlet with inlet screen and sound baffling, and fire retardant, acoustical polyurethane foam sound absorption material. Aluminum enclosure is corrosion-resistant and can be installed inside or outside plant. Two hinged doors on each side provide full access. |
 Automated Drain keeps compressor tanks dry.Motor Guard Corp.
Manteca, CA 95337 6141
Aug 01, 2003 Model RF-2011 Automatic Drain empties accumulated water in compressor tank, eliminating possibility of carryover of water into compressed air lines. It features electrically operated solenoid valve with adjustable drain time control. Positive shut-off, ¼ in. valve won't clog or leak, adapts to existing drain piping, and connects to 110 V power supply with cord and plug. Solid-state, adjustable drain control also features manual override. |
 Emissions Solution suits diesel/gas engine applications.Universal Silencer, A Fleetguard/Nelson Co.
Stoughton, WI 53589 0411
Jul 21, 2003 Combination silencer/catalyst utilizes one of two catalyst capturing techniques within silencer shell: a gasket-wrapped catalyst module or a torturous path configuration with serpentine interlocks around catalyst. Both designs completely seal silencer and ensure that exhaust gas passes through catalyst. Product is available in 4 performance grades with overall attenuation to 40 dB. Base catalyst housing packages are large end-in, end-out configured units. |
 Welding Consumables reduce down time in MIG applications.ITW Welding Automation
Appleton, WI 54912 0206
Jul 02, 2003 Centerfire® contact tips drop in gas diffuser and are locked in place by tightening nozzle. They do not require tools to change, and, when coupled with correct nozzle, stay fixed either flush with end of nozzle, at 1/8 in. recess, or 1/4 in. recess. Large diameter bases and tapered seats increase electrical conductivity and heat transfer. Hand tightened nozzles come with built in spatter shields that protect gas diffusers and facilitate smooth gas flow. |
 Faucets are for high-end residential kitchens.Geberit Mfg., Inc.
Michigan City, IN 46360 8008
Jun 13, 2003 Residential line of faucets for sink, entertainment, and cooking preparation areas include spout styles with high arcs, sleek, double-jointed spouts, and wristblade and lever handle options. Faucets come in polished brass, polished chrome, and brushed nickel finishes. ForeverShine™, applied over chrome finish, provides limited lifetime warranty. Accessories include sink strainers, disposal stoppers, soap dispensers, and dishwasher air gaps. |
 Pig Tracking System handles offshore applications.Pipeline Inspection Company Ltd
Houston, TX 77055
Jun 05, 2003 Pig Tracking System consists of transmitter, tracking sensors, and standard batteries. Pipeline inspection transmitters handle 2–72 in. pipe diameters. User installs transmitters inside pig, launches pig, and waits for signal from either pig tracking sensors or optional wand. Transmitters are pressure and temperature resistant and water tight. Self-contained sensors are non-intrusive and can be strapped to pipe. Calibration is not required. |
 Tub Filler/Overflow System has low-profile design.Geberit Mfg., Inc.
Michigan City, IN 46360 8008
May 21, 2003 Available with chrome, PVD brass, or brushed nickel finish, Cascading Tub Filler and bath waste/overflow system has fill rate of 18 gpm. Product fits tub wall thicknesses from .06–.75 in. Unit uses series of screens to comb water flow, creating soft crystal pattern that keeps flow from wandering. Cable drive drainage system includes built-in back flow preventer and maintenance-free cased cable to actuate drain plug. All mechanical components are made from stainless steel and brass. |
 Screened Orifice suits medical applications.Lee Company, The
Westbrook, CT 06498 0424
Apr 14, 2003 IMH Screened Orifice is a miniature restrictor preinstalled in male to female luer adaptor with integral safety screen to protect orifice from contamination. Orifice and screen are 300 Series stainless steel and adaptor is medical grade polypropylene. Suited for liquid and gas applications, orifice comes in 18 standard flow rates and is 100% flow tested on water or nitrogen to ensure that each part is within ±5% of nominal flow rate. |
(Showing headlines 61 - 80) 1 2 3 4 5 6
|
|
|