Probe and Heated Filter System filters sample gases.

Click Here to Enlarge Picture

November 1, 2011 - Comprised of high-temperature probe, heated filter, and stainless steel internal tubing, Model 7240 is intended for extraction and filtration of gases sampled from industrial applications such as syngas, gasification, and stack gas analysis. Unit mounts directly on sample extraction point and filters gas sample at process temperature. Gas sample is then directed to gas analyzer, which may be located some distance away from sample point.

(Archive News Story - Products mentioned in this Archive News Story may or may not be available from the manufacturer.)
Original Press release

Nova Analytical Systems Inc.
1925 Pine Ave.
Niagara Falls, NY, 14301 2398
USA



Analytical Company Offers Sample Conditioning Option with Syngas & Gasification Analyzers


Nova Analytical Inc, a 30 year veteran in gas analysis, introduces the Nova Model 7240 Probe & Heated Filter System.

The Model 7240 is intended for extraction and filtration of gases sampled from industrial applications such as syngas, gasification, and stack gas analysis.

Frequently, industrial sample gases contain soot or particulate that is inherent to the process or is derived from combustion. This particulate must be extracted from the sample gas as close to the extraction to point as possible avoid sample line occlusions and low flow conditions. The Model 7240 is designed for this purpose.

The Model 7240 is comprised of a high-temperature probe, heated filter, and stainless steel internal tubing. The unit mounts directly on the sample extraction point and filters the gas sample at process temperature. The gas sample is then directed to the gas analyzer which may be located some distance away from the sample point.

To cope with particulate accumulation in the probe, the Model 7240 Probe & Heated Filter has a blow-back feature which blasts a jet of air or N2 back through the filter and into the throat of the probe. This brief blast blows the accumulated particulate out of the sample system and back into the process.

The Nova Model 7240 Probe & Heated Filter System is frequently specified with industrial analyzer systems such as:

Nova 970 Series Syngas and Gasification Analyzers

http://catalog.nova-gas.com/item/all-categories/roduct-lines-syngas-gasification-970-series-syngas/974a-syn-gas-analyzer?plpver=10&categid=100&prodid=1235&origin=keyword

Nova 7200 Series Continuous Flue Gas Analyzers

http://catalog.nova-gas.com/item/flue-gas-analyzers-emissions-analyzers/continuous-flue-gas-analyzer-7200-series-2/7200-1-2-3-f1?&bc=100|1004|1096|1190

Nova 7900 Series Steel Heat Treat Analyzers

http://catalog.nova-gas.com/item/all-categories/all-categories-multigas-analyzers/item-1649?&bc=100|1004|1234|1235|1003

Nova 8000 Series Blast Furnace Top Gas Analyzers

http://catalog.nova-gas.com/item/steelmaking/tinuous-blast-furnace-top-gas-analyzer-8000-series/series-8004?&bc=100|1004|1100|1075#Specifications

Contact Nova Analytical Systems Inc. for more information on this and other gas analysis equipment.

1-800-295-3771

sales@nova-gas.com

websales@nova-gas.com

www.nova-gas.com

blog: http://www.nova-gas.blogspot.com
Print Story
Print | 
Email |  Comment   Share  
Contacts: View detailed contact information.


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
To submit comment, enter the security code shown below and press 'Post Comment'.
 



 See related product stories
More .....
 See more product news in:
Fluid and Gas Flow Equipment
 More New Product News from this company:
Transportable Biogas Analyzers take simultaneous measurements.
Landfill and Biogas Analyzers feature portable design.
Gas Analyzers measure syngas and gasification atmospheres.
Flue Gas Analyzers include built-in sample pump.
More ....
 Other News from this company:
NOVA Analytical Systems Re-Launches Sample Conditioning System with New Features
Tenova Goodfellow Inc. Acquires Nova Analytical Systems
Analytical Company Re-Launches Hydrogen Purity Analyzers for Power Industry
Analytical Company Re-Launches Landfill Gas & Biogas Analyzer Series
NOVA Analytical Systems Inc. Launches New Website with ThomasNet On-line Catalog
More ....
 Tools for you
Watch Company 
View Company Profile
More news from this company
E-Mail Story
Save Story
Search for suppliers of
Gas Filters
Join the forum discussion at:
Tools of the Trade


Home  |  My ThomasNet News®  |  Industry Market Trends®  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2013 Thomas Publishing Company. All Rights Reserved.
Terms of Use - Privacy Policy



Error close

Please enter a valid email address