Company News

Nova Analytical Systems, Inc.

1925 Pine Ave., Niagara Falls, NY, 14301, USA

  • 866-586-9633

Latest New Product News from
Nova Analytical Systems, Inc.

Test & Measuring Instruments

DuraNOVA Continuous Gas Analyzer features multi-point capability.

Sep 29, 2017

DuraNOVA Continuous Gas Analyzer consists of smart sensors, smart modules and controls. Unit’s design features turnkey sample conditioning, gas analysis, environmental management and data communication. Product enables user to configure an alert frequency which sends maintenance alert to the control room. Gas analyzer is built on heavy duty platform.

Read More

Test & Measuring Instruments

Transportable Biogas Analyzers take simultaneous measurements.

Jul 20, 2012

Utilizing durable detectors for simultaneous measurement, 920P Series analyzes biogas process or atmospheres in any combination of oxygen, carbon dioxide, hydrocarbons as methane (CH4), and hydrogen sulfide; option for methane only measurement is also available. Bench top style cabinet makes analyzer suitable for use in shops and labs. Analyzers are supplied with electrochemical O2 detector, with... Read More

Test & Measuring Instruments

Landfill and Biogas Analyzers feature portable design.

Jan 03, 2012

Featuring built-in water separator to help prevent moisture contamination of detectors, Nova 900P Series analyzes oxygen, methane, and carbon dioxide in recovered gases at landfill and biogas sites. In operation, built-in sample pump draws recovered landfill gas through filters and meters to water separator. Sample is then pulled into sensors and detectors for analysis. Packaged in weatherproof... Read More

Fluid & Gas Flow Equipment

Probe and Heated Filter System filters sample gases.

Nov 01, 2011

Comprised of high-temperature probe, heated filter, and stainless steel internal tubing, Model 7240 is intended for extraction and filtration of gases sampled from industrial applications such as syngas, gasification, and stack gas analysis. Unit mounts directly on sample extraction point and filters gas sample at process temperature. Gas sample is then directed to gas analyzer, which may be... Read More

Test & Measuring Instruments

Gas Analyzers measure syngas and gasification atmospheres.

Apr 22, 2011

Available in wall-mount or portable formats, Nova 970 Series is intended for analysis of synthetic gas and gasification atmospheres or other industrial process gases for any combination of methane, carbon dioxide, carbon monoxide, hydrogen, and oxygen. Hydrogen analysis is fully compensated for effects of other measured interfering gases, and all gases are available with analysis range of 0-100%. Read More

Test & Measuring Instruments

Flue Gas Analyzers include built-in sample pump.

Aug 05, 2004

Series 7200 offers continuous analysis of flue gas for any combination of O2, CO, CO2, NOx or combustibles from combustible processes burning clean fuel gas. With appropriate sample preconditioning, units can also measure sample gases from oil or coal-fired processes. Analyzers include digital readout for each gas, recorder output, automatic condensate removal, plus multiple... Read More

Test & Measuring Instruments

NO/NOx Analyzer uses chemiluminescent principle.

Jun 25, 2004

Model 300 CLD Analyzer continuously measures total concentration of oxides of nitrogen within gaseous sample. Method is based upon chemiluminescent reaction between ozone and nitric oxide (NO) to form nitrogen dioxide and oxygen. Features include 8 switch selectable ranges from 0-3 ppm to 0-10,000 ppm NO/NOx, critical flow orifice flow control, and digital diagnostics. Read More

Oxygen Analyzer is explosion proof.

Jun 10, 2002

Model 410N7MC utilizes temperature compensated electrochemical cell to provide continuous measurement of oxygen in process gas. Calibration can be done without having to open enclosure by using magnetic wand and built-in calibration gas selector valve. Analyzer includes LCD digital display meter and 4-20 mA output. Options include alarms, built-in pump, calibration valve, pressure regulator, and... Read More

Test & Measuring Instruments

Hydrogen Analyzer monitors power equipment.

May 06, 2002

Portable Model 380WP Tri Gas Analyzer monitors hydrogen purity in power generators and synchronous converters which use hydrogen gas for cooling. It also monitors CO2 in hydrogen and CO2 in air during shutdown and startup purge procedure. All gases are detected on single temperature compensated thermal conductivity cell. Front panel switch selects desired range. It has digital readout and... Read More

Test & Measuring Instruments

Flue Gas Analyzer monitors combustion processes.

May 06, 2002

Portable Model 362WP continuously measures O2, CO, and NOx in flue gases from most combustion processes. Separate digital readouts are provided for each gas. It has built-in sample pump, flowmeter, filter/condensate trap and rechargeable gel cell battery. Measurement ranges are 0-25.0% 02, 0-2000 ppm NOx, and dual ranges of 0-2000 ppm and 0-4.00% CO. Recorder outputs, weatherproof case, and... Read More

Test & Measuring Instruments

Dew Point Transmitter displays on LED meter.

Apr 17, 2002

Model 202RT Dew Point Indicator/Transmitter, for use on atmosphere gases from an endothermic generator, continuously monitors gas dew point and displays it on large, easy-to-read LED meter. It also transmits 4 to 20 ma and RS-485 outputs. Power is from 12 to 24 Vdc. There are no pumps or other moving parts. Read More

Test & Measuring Instruments

Flue Gas Analyzer checks oxygen and carbon monoxide.

Nov 09, 2001

Portable Model 360 measures oxygen and CO present in flue gas sample. It uses customer replaceable sensors, which have life expectancy of 2-3 years. Analyzer is complete with built-in sample pump, 12 ft of sample hose, filter/condensate trap, flowmeter, rechargeable gel cell battery, LCD digital readouts, and temperature sensor. It indicates stack temperature for fuel efficiency calculations.... Read More

Sensors Monitors & Transducers

Monitors provide unattended analysis of flue gases.

Nov 06, 2001

Model 7600 Series of Continuous Emission Monitors consist of sampling probe, heated filter and sample line, sample conditioner, gas detectors, microprocessor controller and data acquisition system. Infrared detectors include CO, SO2, CO2, chemiluminescence detector for NOX, electrochemical detector for O2 and FID detector for hydrocarbons. Monitors are enclosed in free-standing NEMA 12 cabinet... Read More