Company News

Electro Industries/Gaugetech

1800 Shames Dr., Westbury, NY, 11590, US

  • 516-334-0870

General Information:
Erran Kagan
USA
Phone: 516-334-0870

Share Like Tweet Add Email

Latest New Product News from
Electro Industries/Gaugetech

Test & Measuring Instruments, Communication Systems & Equipment, Green & Clean

Power and Energy Meter supports BACnet MS/TP communication.

January 12, 2015

Featuring native BACnet MS/TP serial communication, Shark® 50B supplies power and energy data to building automation systems. Unit comes pre-programmed with 34 BACnet objects for seamless integration into existing BACnet networks. Meter also supports Modbus over TCP/IP so that it can communicate to stand-alone energy management system or energy dashboard. In addition to building automation, meter supports LEED projects and other green building initiatives. Read More

Software

Energy Management Software facilitates problem solving, reporting.

November 10, 2014

Designed for energy providers and consumers, Communicator EXT™ v4.0 provides problem solving tool that supports almost all EIG (Electro Industries/Gaugetech) meters. UI simplifies analysis of power and energy usage as well as power quality and aids in production of reports used to manage and visualize energy usage and reliability throughout enterprise. Read More

Test & Measuring Instruments, Communication Systems & Equipment

High Density Energy Metering System comes in NEMA 1 enclosure.

July 22, 2014

Without requiring complex redesign, Shark® MP200™ in Enclosure enables switchgear capability expansion and/or facilitates metering of circuits. This multipoint energy metering system in NEMA 1 type enclosure assembly suits high-density applications. Offering 0.5% Class Energy accuracy on all circuits, solution provides up to 24 energy metering points in one CPU. Unit can be ordered as eight 3-phase circuits or 24 single-phase circuits and offers multiple connectivity choices. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers, Communication Systems & Equipment

Power Quality Meter supports low-voltage power supply option.

May 5, 2014

Nexus® 1500 power quality monitor can be used with low-voltage power supply option that is UL rated at 18–60 Vdc to support 24–48 Vdc systems. This option lets meter be used in applications where it needs to remain on in order to record power quality events when AC mains voltage becomes unstable. In addition to 10 MHz resolution transient capture for waveform recording, standard features include one GB storage memory, color touchscreen UI, and multiple communication ports. Read More

Test & Measuring Instruments, Computer Hardware & Peripherals, Communication Systems & Equipment

Power Meter features IEC 61850 protocol capability.

August 9, 2013

With IEC 61850 capability through INP300S Network Card, Shark® 200 Multifunction Power and Energy Meter can provide integral power information for smart substation solutions. Network card includes support for Modbus and IEC 61850 protocols simultaneously as well as support for 5 simultaneous MMS clients. Device is configurable for multiple logical nodes and provides both buffered and unbuffered reporting. Additional features include dual Ethernet 61850 and/or DNP3.0 Ethernet support. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers, Communication Systems & Equipment

Multi-Point Metering System offers remote display capability.

August 2, 2013

Part of total environmental impact program, Model MP200 allows users to monitor and reduce energy consumption system-wide by allocating costs and responsibility to energy users. WiFi-communicating system is available with optional 3.5 or 5.7 in. HMI LED touchscreen that offers local display and/or remote display over network. Enabling user to view up to 24 metering points, display allows access to real-time metering information anywhere throughout facility. Read More

Test & Measuring Instruments, Communication Systems & Equipment

Multi-Point, High-Density Metering System is WiFi capable.

May 17, 2013

Accommodating up to 24 measurement points for metering in space-limited applications, MP200 provides choice of common communication architectures – serial RS485 using Modbus protocol, wired Ethernet port, or 802.11 Wi-Fi – for relaying data. System secures data using WEP, WPA, or WPA2 encryption when using WiFi. Also, onboard memory allows for data logging and load profiling of energy consumed over time for each circuit, while software enables creation of reports and sub-metering bills. Read More

Test & Measuring Instruments, Communication Systems & Equipment

Power and Energy Meter supports dual Ethernet cards.

March 26, 2013

Offering frequency measurement accuracy up to 0.001 Hz, Shark® 200 supports DNP 3.0 Ethernet, which provides up to 5 simultaneous connections of DNP 3.0 in addition to 7 Modbus sessions per card and full customizable Web Server capabilities. Two separate Ethernet cards, each with its own IP address and MAC address, allow users to send data to multiple networks from same meter. With DNP Ethernet, Shark 200 is suitable for providing telemetry for complex automation and control solutions. Read More

Test & Measuring Instruments, Communication Systems & Equipment

Meter Assembly facilitates switchgear expansion.

December 12, 2012

Supplied in NEMA enclosure, Self-Enclosed Shark® Meter Assembly lets users expand switchgear capability without redesign. This cUL/UL listed product comes pre-wired and in either 120 or 277 V configuration. As retrofit in environments without available metering compartment, assembly can be mounted and wired next to existing switchgear. Available multifunction meters include Shark 100 power and energy meter; Shark 100B with native BACnet/IP protocol; and Shark 200 with data-logging and I/O. Read More

Test & Measuring Instruments, Communication Systems & Equipment

Power Meter performs utility substation measurements.

November 26, 2012

Providing data logging capabilities, Shark® 200 Multifunction Power and Energy Meter is used by industry and utilities worldwide to measure and report on electrical power. Frequency measurement has been optimized to provide accuracy to 0.001%, allowing meter to be used for power system frequency analysis and as frequency transducer. Additional features include real-time clock synchronizing, wide dynamic voltage under-range, and variety of communication port selections. Read More

Test & Measuring Instruments, Communication Systems & Equipment

Electric Panel Meter meets 0.5% accuracy classes.

October 23, 2012

Suited for OEM and commercial applications, Shark® 50 multifunction power and energy meter features component count and DSP design that promote reliability and operational life expectancy. Optional Modbus RS485 serial port can be equipped for digital communication of energy usage data and KYZ pulse to pulse energy usage. Applications include tenant metering, low voltage panel board metering, and other high-volume deployments. Read More

Test & Measuring Instruments, Communication Systems & Equipment

Self-Enclosed Power Meter expands switchgear capability.

May 22, 2012

Supplied in NEMA 12 enclosure, Shark® meter assembly comes pre-wired and configured in either 120 or 277 V (for 277/480 V systems) configuration and is suited for use as retrofit solution in environments where there is no available metering compartment. Assembly can be mounted and wired next to existing switchgear and is available with Shark 100 power and energy meter; Shark 100B, with native BACnet/IP protocol; or Shark 200, with data-logging and I/O. Read More

Vision Systems, Electrical Equipment & Systems, Display & Presentation Equipment

Power Monitor LED Display features USB port for data downloads.

March 31, 2011

Designed for use with Nexus® family of Smart power monitors, P40N+ LED display with USB port has 3 lines of data display and front panel USB port for direct data downloads. Integrated USB port allows unit to connect directly to computer for remote viewing and downloading of all meter data and logs. Product can also act as Master display to Amps and Watts/VAR/PF displays for access to their readings. Read More

Software

Energy Management Software supports Windows® 7 and Vista.

October 22, 2010

Comprised of 5 modules, Communicator EXT v3.0 helps monitor, control, and analyze use of electricity. It enables users to leverage smart metering technology, including multi-generational support for modern and legacy meters installed worldwide. In addition to remote dial-in and outage reporting support, suite offers capabilities that let users view real time readings, configure meters, download stored logs, analyze waveforms, and connect graphical HMI. Read More

Test & Measuring Instruments, Communication Systems & Equipment

Power Meter includes data logging capability.

February 13, 2008

Designed for large-scale deployment within electrical distribution system, panel-mounted Shark 200® offers revenue meter functionality combined with data logging, communication, and field upgradeable I/O capability. Configurable unit includes 2 MB flash memory and 100BaseT Ethernet option, which allows user to connect to web page to view real-time readings. Read More

Test & Measuring Instruments

Sub-Meters facilitate cost allocation.

September 22, 2005

From allocating apartment unit energy costs to tracking in-plant departmental energy expenditures, Shark100-S provides solution for residential, commercial, and industrial sub-metering needs. It offers standard interfaces using Modbus serial, RJ45 Ethernet Modbus TCP, or 802.11 Wireless Ethernet Modbus TCP. Standard Modbus interface allows unit to be interfaced to almost all energy management and SCADA systems, eliminating need for software and communication channels. Read More

Sensors, Monitors & Transducers, Communication Systems & Equipment

Power Quality Monitor uses artificial intelligence.

June 8, 2005

Portable PDA 1252 provides power quality monitoring and reporting using artificial intelligence to diagnose source of power quality event and provide solutions. Unit measures every aspect of power and provide tools for recording trends. Featuring watertight outdoor rated enclosure, monitor uses outdoor-ready connections and is suited for load surveys, monitoring transformer banks, indoor and outdoor electrical monitoring, and power quality analysis. Read More

Sensors, Monitors & Transducers

Digital AC Power Transducer offers RS485 communication.

May 19, 2005

Able to measure 3-phase voltage, current, and power, Shark 100 provides RS485 digital output using Modbus or DNP 3.0 protocols. Design facilitates installation and makes unit suited for embedded power telemetry for industrial, OEM, and Utility applications. DIN rail-mount product offers 120/220 AC or DC power supply, with 24-48 Vdc power supply also available. Read More

Vision Systems, Electrical Equipment & Systems, Display & Presentation Equipment

LED Displays show 9 parameters without scrolling.

February 10, 2005

Multifunction LED Displays feature master/slave capability, allowing use of 3 multi-line LED displays configured to voltage, current, and power. With additional displays, users can obtain 9 LED values from one meter simultaneously. Used as master polling device and volts display, Model P40N broadcasts data to Amp Model P41N and Power Model P43. Technology allows Nexus Meter to have multiple display capability using 1 display port with non-scrolling metering parameters. Read More

Display & Presentation Equipment

HMI Display is offered with on-line historical trending.

January 28, 2005

Suited for substation automation applications, P60N touch screen HMI display for Nexus series meters is offered with on-line historical trending. This allows display to be used for chart recording applications, delivering chart-recorded data in real-time on graphical touch-screen LCD. Features include 320 x 240 pixel, cold-cathode fluorescent display; ability to view multiple meters as well as out of limit alarms; and harmonic spectrum presentation. Read More

Other Company News from
Electro Industries/Gaugetech