Laboratory Baths

Digital Chilling/Heating Dry Bath has 2-position design.
Laboratory Baths

Digital Chilling/Heating Dry Bath has 2-position design.

Comprised of 2 dry baths for biological samples, EchoTherm(TM) Model IC22XT can run 2 separate temperatures from -20 to +100°C and 2 different sample blocks simultaneously. Features include data logger, 30-day count down timer with alarm, and RS232 interface. Compatible with robotic systems, bath can be used with accessory sample blocks for 0.5, 1.5, and 2.0 ml centrifuge tubes; PCR tubes...

Read More »
Laboratory Circulating Bath Systems offer 6-28 L reservoirs.
Laboratory Baths

Laboratory Circulating Bath Systems offer 6-28 L reservoirs.

Available with stainless steel or polycarbonate tank, Open Tank Circulating Bath Systems feature insulating, chemical-resistant top deck that is easily cleaned and disinfected. Stainless steel tank models are available with 6, 10, 20, or 28 L reservoirs and either Advanced Programmable, Advanced Digital, or MX controller. Polycarbonate models, offered with 8, 11, 14, 17, 23, or 28 L reservoirs,...

Read More »
Refrigerated Circulating Baths range from 7-45 liters.
Laboratory Baths

Refrigerated Circulating Baths range from 7-45 liters.

Offered in 40 models, Refrigerating/Heating Circulators feature temperature ranges of -40 to +200°C with temperature stabilities of ±0.005°C. Units have swiveling control head that permits viewing of temperature display anywhere within 180° viewing radius, integral lid docking system for no-mess reservoir cover storage, and corrosion- and chemical-resistant top plate that...

Read More »
Circulating Water Baths offer precision temperature control.
Laboratory Baths

Circulating Water Baths offer precision temperature control.

Configured for use with Brookfield viscometers and rheometers, TC Series is comprised of 4 models with choice of digital or programmable controllers. Control heads swivel, adjusting to position that best suits operator, and menu-driven color touchscreen features Help" button that provides user tips and information. Offering USB, Ethernet, and RS-232 connectivity, series is designed with rounded...

Read More »
Viscosity Baths support ASTM D-445 testing.
Laboratory Baths

Viscosity Baths support ASTM D-445 testing.

Configured for most capillary viscometers, Viscosity Baths offer choice of glass or polycarbonate reservoir. Polycarbonate models have 29 L rectangular reservoir with working depth of 11.25 in., square or round viscometer openings, and max working temperature of 85°C. Glass versions, providing working temperature of 135°C, are available with 17 or 27 L round reservoirs, with working...

Read More »
Circulating Water Baths feature ergonomic design.
Laboratory Baths

Circulating Water Baths feature ergonomic design.

Available in refrigerating/heating and heat-only models with reservoirs sizes from 7-45 L, Circulating Water Baths feature temperature ranges from -40 to +200°C, temperature stabilities to ±0.005°C, and choice of 6 different temperature controllers, including 2 programmable models. Swiveling control head permits viewing of temperature display anywhere within 180° viewing...

Read More »
Laboratory Baths

Compact Chilling/Heating Dry Baths support remote control.

Measuring 6.5 x 4.75 x 3.5 in. without sample block, Peltier-driven EchoTherm(TM) RIC20 Series is designed for remote controlled applications on robotic and benchtop systems using PC. Any number of RIC20s can be used via RS232 I/O port on each unit and PC serial ports, and complex, user-created temperature/time profiles can be run by leaving computer attached to RIC20. Temperatures can be set...

Read More »
Chilling/Heating Dry Baths interface with robotic systems.
Laboratory Baths

Chilling/Heating Dry Baths interface with robotic systems.

Available with 1 or 2 chilling/heating positions, Peltier-driven Chilling/Heating Dry Baths utilize RS232 interface for robotic systems. Units can freeze, chill, or heat samples from -20 to +110°C in assay plates, centrifuge tubes, vials, and most any size test tube. Available in sizes down to 6.5 x 8.75 x 3.5 in., baths feature digital display and control of temperature to 1°C, data...

Read More »
Chilling/Heating Dry Bath features Peltier-driven design.
Laboratory Baths

Chilling/Heating Dry Bath features Peltier-driven design.

Measuring 6.5 x 8.75 x 3.5 in., EchoTherm(TM) Model IC20XR can freeze, chill, or heat samples from -10 to 110°C in assay plates, centrifuge tubes of all sizes, vials, and most any size test tube. Unit features digital display and control of temperature to 1°C, countdown timer, data logger, and RS232 interface to control unit by computer or to record data. Dry bath is suited for...

Read More »
Penetrometer Bath
Laboratory Baths

Penetrometer Bath

o Conforms to ASTM and related specifications o Conditions petroleum samples and others requiring close temperature control prior to or during testing o For use with manual and microprocessor penetrometer models o Digital temperature control with low-liquid and overtemperature safety cut off Constant temperature water bath for conditioning samples prior to a penetration test. Full visibility bath...

Read More »
Tekna Manufacturing LLC Announces NFPA 99 Compliant Model 7200 Multiplace Chamber
Sponsored

Tekna Manufacturing LLC Announces NFPA 99 Compliant Model 7200 Multiplace Chamber

Tekna is a leader in Monoplace and Multiplace Hyperbaric Chambers for Hyperbaric Oxygen Therapy (HBOT), offering products that set the standard for quality and innovation. Our new 7200 series of multiplace chambers is a state-of-the-art system that integrates advanced engineering with a plethora of features and options making it the industry's premier HBOT system. To learn more, see our video.

Read More »

All Topics