New Total Organic Carbon Analyzer Uses UV Persulfate Oxidation Method

Press Release Summary:

The Total Organic Carbon Analyzer detects generated carbon dioxide using highly stable NDIR detector for analysis. It is housed in dual compartment enclosure that is rated to IP54 and NEMA 3 standards. The unit features intuitive touchscreen display that shows output/input data, status information, alarms and fault conditions. The analyzer is suitable for applications such as drinking water, feed and cooling water in manufacturing, runoff water and wastewater.


Original Press Release:

New ECD Total Organic Carbon (TOC) NDIR Analyzer Assures Municipal & Industrial Water Quality

Municipal & Industrial Wastewater, Drinking Water, Power Generation and More

Anaheim, CA—August 23, 2018— Engineers responsible for municipal drinking water or industrial process water, as well as wastewater effluent, will discover that the new next-gen precision Total Organic Carbon (TOC) Analyzer from ECD Analyzers with non-dispersive infrared (NDIR) detection technology helps them know with high confidence that their treatment job is complete and that treated water is ready for use or re-use.

Installing ECD’s TOC Analyzer helps plants reduce costs, increases operational efficiency and supports regulatory compliance. Organic matter is nearly always present in water, whether it is surface water, raw or treated water. Measuring total organic carbon, or TOC, can be an important process variable when monitoring and controlling organic matter in water.

There are many Industries and applications for ECD’s TOC Analyzer. They include drinking water, feed and cooling water in manufacturing, runoff water and wastewater being discharged to the environment where an accurate and reliable TOC measurement is required to protect the water supply.

ECD’s TOC Analyzer is a full-featured instrument that utilizes the UV persulfate oxidation method, which detects generated carbon dioxide (CO2) using its highly stable NDIR detector for analysis. This method and the analyzer conform to: US EPA, DIN, CE, ASTM and NAMUR regulations, as well as ISO.

Using the ECD TOC Analyzer is simple: the water sample is first acidified and then sparged to remove inorganic carbon. The remaining liquid is mixed with sodium persulfate and digested by two high-performance reactors. The resulting CO2 is then stripped from the liquid and, after drying, its concentration is measured by the NDIR analyzer. The analyzer measures TOC’s ranging from 0-5 mg/L to 20,000 mg/L.

The analyzer’s advanced design features a valve-free sample line, which largely eliminates blockages. The analyzer’s auto clean, autocalibration and autovalidation functions guarantee correct, reliable values that can be reproduced at any time without the need for manual intervention.

Unlike conventional analyzers where the flow is controlled by a glass tube rotameter, the carrier gas flow with the ECD TOC Analyzer is controlled digitally. The flow is monitored via built-in smart diagnostics and if an abnormal value is detected, the analyzer stops automatically and displays a warning alert.

The ECD TOC Analyzer is housed in a dual compartment enclosure. The water sample components are in one compartment, and the electronics are located in a second compartment for safety and highly reliable operation. The analyzer compartment is rated IP54, NEMA 3, and conforms to EN610004-2, EN610004-4, C46-022, EN 55022 and EN 61326.

The ECD TOC Analyzer features an optional fast loop reservoir for safe operation in case of a sample loss. It maintains a constant sample flow and switches the analyzer to standby in the case of insufficient flow (dry running). As soon as the sample flow restarts, the measurement is process is resumed.

Highly intuitive and simple to use, the ECD TOC Analyzer’s user interface is a touchscreen display located on the front of the analyzer. All output/input data, status information, alarms and fault conditions are shown on the display. Simply pressing the touchscreen buttons provides access to commands and settings. The system is password protected for security.

Monitoring the TOC level of plant incoming source water will detect early pollution events and prompt action to be taken to divert or close the raw water intake before the treatment plant is contaminated. The monitoring of TOC content in finished water prior to distribution is also required in some countries to control disinfection by-products.

TOCs in municipal drinking water and wastewater are regulated by the US EPA, state and local water quality standards. The same is true for industrial process wastewater effluent at plant discharge. Food/beverage, pharmaceutical and other industries rely on TOC measurement for analysis of wastewater prior to discharge. In addition, the power generation industries rely on TOC measurements for water quality concerning cooling water, condensate and boiler feed water.

About ECD Analyzers

ECD Analyzers is a subsidiary of Electro-Chemical Devices, Inc., which is a manufacturer of liquid analytical process instrumentation. Founded in 1977, ECD has been in business for over 40 years and has built its industry leading reputation by its commitment to customers through this basic approach: Provide quality products, develop technical innovations and provide responsive, knowledgeable service.

Company Contact: Ryan Balgos

Company Address: 1500 N. Kellogg Dr., Anaheim, CA 92807 USA

Web: http://www.ecdi.com Email: sales@ecdi.com Tel: 800-729-1333 Tel: 714-695-0051 Fax: 714-695-0057

Editor’s Contact: Randy Brown: 909-223-6700 Email: brownr@rbmarketing.com Web: www.rbmarketing.com

Download Spec Sheet

All Topics