Adaptor stores and recalls sensor data.

Press Release Summary:



In-Line TEDS Adaptor features interface chip that allows identification, location, and sensitivity relative to attached piezoelectric sensor to be stored. Device allows ICP® accelerometers that do not have TEDS functionality to be used in typical TEDS applications such as large channel count modal analysis and structural testing. Use of adaptor eliminates cable connection errors and reduces set-up time.



Original Press Release:


In-Line Adaptor Enables Piezoelectric Sensors with TEDS Capabilities


January 6, 2003, Depew, NY - New In-Line TEDS Adaptor, from the Electronics Division of PCB Piezotronics, Inc., stores and recalls TEDS (Transducer Electronic Data Sheet, IEEE 1451.4 standard) data for the ICP® sensor which is attached. In-Line TEDS Adaptor features an interface chip that allows the identification, location, sensitivity, and other information relative to the attached sensor to be stored.

The device allows ICP® accelerometers that do not have TEDS functionality to be used in typical TEDS applications such as large channel count modal analysis and structural testing. The use of PCB's In-Line TEDS Adaptors expedites large channel count testing by eliminating cable connection errors and reducing the set-up time involved in recording sensor model numbers, calibration data, etc.

For additional information, contact the Electronics Division of PCB Piezotronics, Inc., toll-free at 800-828-8840; E-mail: electronics@pcb.com; or fax 716-684-0987. For other PCB products, contact PCB directly at 716-684-0001, or visit our web site at www.pcb.com.