Advertisement
|
|
Test & Measuring Instruments ->
Probes ->
Chemical Probes
Chemical Probes
(Showing headlines 21 - 40) 1 2 3 4 5
|
 Moisture Meter offers 3-in-1 functionality.Delmhorst Instrument Co.
Towaco, NJ 07082
Jun 14, 2007
Featuring Pin Mode, Scan Mode, and Thermo-hygrometer with RH sensor, TotalCheck enables restoration contractors, IAQ specialists, general contractors, and flooring installers to identify problem areas in all building materials. Integral contact pins mounted on top of meter provide 5/16 in. penetration, and connector accepts external electrodes. Unit supports job groupings and can recall up to 1,400 stored readings on screen, each with date and time stamp.
|
Dye Injector targets air-conditioning and refrigeration.Spectronics Corp.
Westbury, NY 11590
Apr 30, 2007
Spectroline® BigEZ(TM) contains enough fluorescent dye to treat systems containing up to 16 gal of lubricant, and features disposable dye cartridge, which is calibrated in 1/8 oz increments. Injector consists of handle/threaded shaft and collar assembly, 4 oz solvent-free AR-GLO® fluorescent leak detection dye, and hose assembly with low-loss fitting. Cartridges are available for mineral oil, polyol ester and alkyl benzene lubricants.
|
 Leak Detector offers multi-testing capability.Cincinnati Test Systems Inc.
Village Of Cleves, OH 45002
Apr 20, 2007
Utilizing proprietary test algorithms processed on 32-bit system, Sentinel I-24 is multi-test configurable for any test requirement. It includes auto calibration, up to 5 programmable tool controls, and automatic part setup that can handle up to 99 programs. Data storage is expandable through USB port and offers part traceability. Suitable for wall mount or benchtop mounting, detector supports Ethernet, USB, and RS232 communication.
|
Gas Analyzer measures trace amounts of moisture in argon.GOW-MAC Instrument Co.
Bethlehem, PA 18017 8986
Jan 26, 2007
Featuring high signal gain and electro-optical modulation for noise and drift rejection, Series 1400 Analyzer offers sensitivity of 10 ppb for H2O. Model 1400-A covers 0-2/0-20 ppm, while Model 1400-B covers 0-20/0-200 ppm. Detection is based on spectral emission of argon plasma. Analyzers also offer on-line, continuous trending of moisture concentration with no need for sample injection or separation columns, fast recovery from high moisture levels, and over-range protection.
|
Probes provide extremely small sample measurement.Thermo Electron Corp.
Waltham, MA 02454
Jan 12, 2007
At less than 3 mm in diameter, ROSS Micro pH Electrode (Model 8220BNWP) can be used with Orion PerpHecT® meters to enable measurement of pH while allowing for direct temperature measurement and compensation without separate ATC probe. Used independently or in conjunction with Orion meters, Micro Automatic Temperature Compensation Probe (Model 928007MD) features SS sensing tip measuring less than 1 mm in diameter, allowing users to obtain temperature of samples as small as 10 µL.
|
 Sensors are designed for industrial/municipal applications.Analytical Technology, Inc.
Oaks, PA 19426
Dec 20, 2006
Available in several mounting configurations, pH/ORP sensor utilizes sealed reference design where second glass pH electrode acts as reference element to protect sensor from chemical poisons. Electrode used for ORP measurement can be platinum or gold depending on process solution. Pre-amplifier encapsulated in body ensures stable readings in harsh environments, while sensor diagnostics alerts user in event of electrode breakage, or integral temperature sensor failure.
|
 Digital Meter detects leaks in compressed air systems.Dwyer Instruments, Inc.
Michigan City, IN 46361 0373
Dec 15, 2006
Using calorimetric measuring principle, Series CAM detects compressed air leaks, providing quick, accurate readout. Unit is virtually maintenance-free and available with ½, 1, or 2 in. NPT process connections, allowing users to choose size and range that best suits their needs.
|
Leak Detector features modular design.Alcatel Vacuum Products, Inc.
Hingham, MA 02043
Nov 30, 2006
Composed of 3 separate 19 in. rack-compatible modules, Model ASI 20 MD is suited for integration into any leak detection system, including hard vacuum and sniffing tests. Analyzer cell with dual filaments and electron multiplier amplification system ensure sensitivity of 5.10-11 mbar.l/s. Detector includes molecular drag pump with intermediate port and rotational speed of 27,000 rpm, as well as autocalibration system, and flat remote control panel with multiple displays.
|
Leak Detector pinpoints very small leaks.Alcatel Vacuum Products, Inc.
Hingham, MA 02043
Nov 16, 2006
Portable, dry sniffing Model ASM 102 S is suitable for applications where unit may have to be placed sideways, at an angle, or carried around frequently. System can be used for control and maintenance of any part or installation used under pressure, including underground cables and tubes, valves and manifolds, and underground or external storage tanks. Unit is suited for testing Kerosene tanks, liquid Propane gas and oil tankers, offshore gas installations, and hydrogen gas supply lines.
|
Infrared Camera detects VOC leaks.Flir Systems, Inc.
North Billerica, MA 01862
Oct 23, 2006
Suited for petrochemical facilities, ThermaCAM® GasFindIR(TM) utilizes infrared imager employing sensitive detector and cold filter to observe active leaks of VOCs such benzene, propane, and methane. Real-time thermal images of gas leaks appear as black smoke onscreen. Users can capture and record images to any off-the-shelf video recorder for archiving, documenting, or emailing.
|
 Leak Detector senses water leaks and sounds alarm.Dwyer Instruments, Inc.
Michigan City, IN 46361 0373
Sep 20, 2006
Battery or line powered, Series WD2 relies on electrical conductivity of water to change resistance across 2 contacts located at base of enclosure. When there is enough water to bridge contacts, alarm is triggered. Detector can be placed on flat surface under HVAC equipment, dishwashers, washing machines, refrigerators, compressors, and in electrical switchgear rooms.
|
 Benchtop Analyzer determines package integrity.MOCON
Minneapolis, MN 55428 1010
Sep 19, 2006
In one analysis, PAC CHECK® Model 840 lets packagers measure 2 critical variables - residual headspace oxygen (O2) and absolute package leak rate - that determine package shelf-life. Unit produces absolute leak number based on application of Poiseuille's law, which yields total hole diameter leak size based on measurements of pressure and flow. It saves up to 240 data points in internal memory and can also send information to computer via RS-232 data line.
|
 In-Line Sensor monitors pH of liquid chemicals.Norcross Corp.
Newton, MA 02458 1829
Sep 13, 2006
Installed directly in fluid line, In-Line pH Sensor incorporates transmitter, which converts mV signal to 4-20 mA for transmission to controller. Featuring flat tip probe with glass insert, sensor has integral reservoir, which traps fluid to keep probe tip wet during job changes and to prevent drying out. Applications include liquid chemical processes such as water-based printing inks, food production, pharmaceutical, and general manufacturing.
|
 pH Sensors perform in temperatures to 293°F.Emerson Process Management / Process Liquid Division / Uniloc Division
Irvine, CA 92606
Sep 11, 2006
Models 3300HT and 3400HT pH sensors handle pressures of 100 psig at 145°C or 250 psig at 100°C. Model 3400HT retractable design allows removal for calibration and maintenance without process shutdown, while 3300HT insertion/submersion design allows variable insertion depths and removal without twisting. Sensors feature pH-resistant glass formulations, replaceable Teflon® reference junction, and chemically resistant Ryton(TM) body. Several mounting and cabling options are available.
|
 Moisture Sensors eliminate water contamination in fluids.Kittiwake Developments Ltd
West Sussex BN17 7LU United Kingdom
Aug 15, 2006
Constructed from stainless steel and protected to IP65 or IP67, ANALEXrs Online Moisture Sensors screw directly into oil flow to detect moisture content of water up to oil's saturation point. With self-diagnosing digital and analog outputs, sensors can be integrated into existing condition monitoring and operating control systems. They communicate with existing systems using industry standard 4-20 mA, RS232, RS485, CAN, and 802.11b WLAN outputs.
|
 Ultrasonic Diagnostic Tool uses 2-tiered diagnostic process.Tracer Products
Westbury, NY 11590
May 03, 2006
Tracerline® Marksman(TM) receiver unit utilizes heterodyning technique to convert inaudible sound into audible sound, then Sound Signal Technology(TM) fine-tunes into natural sound emitted by defect. When attached to receiver, 12 in. hollow probe accentuates air sounds, while solid contact probe accentuates sounds of wear/grinding inside gears. Ten-bar LED display indicates intensity of incoming signals from problem source to ensure error-free diagnosis.
|
Mass Spectrometer Leak Detectors use helium as tracer gas.Varian, Inc.
Palo Alto, CA 94304
Mar 31, 2006
Portable Model VS PR02 and cart-mounted Models VS MR15 and VS MD30 test integrity of systems, chambers, containers, and parts. With push of button, units precisely locate and measure leaks in objects, such as power plant condensers, food packaging, automobile air bags, and medical devices. Detectors are designed to meet maintenance needs of industrial processing, parts manufacturing, high energy physics, and general research applications.
|
 Vacuum Gage provides portable leak testing solution.Cincinnati Test Systems Inc.
Village Of Cleves, OH 45002
Mar 30, 2006
Supplied in re-usable custom carrying case that protects against damage and ingress of dirt, Digital Vacuum Gauge features KF16 fitting that connects directly to system vacuum fittings to take readings from 1 Pa to atmosphere. Portable troubleshooting device verifies system vacuum pressures, and integral display indicates values in 1 of 3 selectable engineering units.
|
 Leak Detection Kit locates refrigerant leaks.Spectronics Corp.
Westbury, NY 11590
Jan 23, 2006
Spectroline® HVLD-80GS finds leaks in all sizes and types of air conditioning and refrigeration systems, in single inspection. Included BIB-150P Built-In-Ballast(TM) UV lamp with 150 W mercury vapor bulb produces ultra-high UV intensity to make faintest leaks glow brightly. Kit also includes 6 assorted GLO-STICK® fluorescent dye capsules, 2 bleed valves, UV-absorbing glasses, 8 oz spray bottle of GLO-AWAY(TM) dye cleaner, and plastic carrying case.
|
 Portable Leak Detector aids in troubleshooting process.Cincinnati Test Systems Inc.
Village Of Cleves, OH 45002
Jan 05, 2006
Able to detect leaks in chambers, connections, or parts, Leak Finder consists of rechargeable container for helium gas with spray nozzle. Helium is sprayed onto suspected leak location and can then be observed on mass spectrometer system that continuously measures helium concentration while under vacuum. Leak Finder kit includes recharge fitting with integral valves, pressure gage, and pressure relief valve for safe recharging.
|
(Showing headlines 21 - 40) 1 2 3 4 5
|
|
|