 Automated Analyzer optimizes mineral processing operations.FEI Company
Hillsboro, OR 97124
Sep 11, 2008
Using scanning electron microscope equipped with field emission gun (FEG) and multiple high-speed energy dispersive X-ray spectrometers (EDS), model MLA 600F mineralogy analyzer acquires image and composition information from large number of samples. Software uses data to acquire and measure characteristics such as mineral type and distribution, liberation and association-essential properties of ore that must be accommodated in mineral processing to achieve maximum metal recovery.
|
Analysis System evaluates print head performance.Imagexpert, Inc
Nashua, NH 03063
Aug 20, 2008
JetXpert combines strobing technology with customized optics and ImageXpert software to provide flexible platform for analyzing performance of any print head through drop-in-flight analysis and visualization. Strobe is slaved to 50 Hz-100 kHz frequency of print head, while optical design allows for imaging and analysis of drops down to 3 pL in volume. ImageXpert is used for image analysis including drop trajectory, drop velocity, volume, radius, ligament, and break off length.
|
Imaging System provides multispectral analysis.Cambridge Research & Instrumentation
Woburn, MA 01801
Dec 18, 2007
Nuance 2 converts any brightfield or fluorescent microscope into multispectral imaging workstation. Flex(TM) liquid crystal tunable filter provides spectral imaging from 420-720 nm (VIS model) and 500-950 nm (GNIR model), covering full range of available chromogenic dyes and in vitro fluorophores. CCD cooling allows for low-light imaging, while analytical software offers spectral unmixing tools, including Real Component Analysis(TM) algorithm, which automatically identifies spectral signatures.
|
 Microscope System determines content of NMI in steel.Carl Zeiss Microimaging, Inc.
Thornwood, NY 10594-1939
Nov 20, 2007
Based on AxioImager.Z1m upright microscope or Axio Observer.Z1m inverted microscope, NMI system is designed for analyzing Non-Metallic Inclusions (NMI) for compliance with EN 10247 European standard as well as previously existing standards. It can be tailored for other image analysis applications and determines quality through automated process performed by repeatable mathematical calculations. Solution also supports simultaneous and automatic objective analysis of up to 6 samples.
|
Image Analysis System quantifies regional brain atrophy.Cortechs Systems & Consulting
Santa Rosa, CA 95404
Oct 02, 2007
NeuroQuant(TM) receives magnetic resonance image (MRI) scans, routed from scanner or PACS as input, and automatically return age-related atrophy reports as well as numerical and color-blended anatomical volumes annotated with graphical overlays to physician's desktop. Using intelligent image analysis and extraction methods, system can be used to monitor disease processes in patients or as means for deriving quantitative imaging biomarkers in clinical trial research.
|
Beam Propagation Analyzer measures 10 x 7 x 17 in.Ophir-Spiricon Inc.
Logan, UT 84321
Jul 27, 2007
Model M2-200S Beam Propagation Analyzer features UV operation between 250-370 nm, visible operation from 400-700 nm, and NIR operations from 650-1,100 nm (1,064 nm YAG) and 1,000-1,800 nm (1,064 nm YAG plus telecom). All measurements and translations as well as incremental beam attenuation are automatically controlled by M2-200S software. ISO compliant unit comes in M2x, M2y, Ky, Ky, BPPy, BPPy, width at waist Wy, Wy, and waist location at Zy, Zy.
|
 Software creates thermal imaging videos in AVI format.Optotherm, Inc.
Sewickley, PA 15143
Sep 28, 2006
Thermalyze v4.5 creates videos that can display thermal images, 3D thermal images, strip charts, line profiles, histograms, and temperature statistical data from images. Videos can be emailed, incorporated into reports, and used for training and marketing. Thermal imaging analysis software enables users to locate position of thermal anomalies with respect to reference point.
|
 Analyzer calculates contaminant concentration of liquids.Fluid Imaging Technologies
Edgecomb, ME 04556
Apr 28, 2006
PetroCAM© oil analysis instrumentation integrates imaging, measuring, and reporting of droplet and particle concentration into single system. Hi-res digital images of suspended oil droplets, grains of sand, or other fluid-borne particles are displayed in interactive scattergram for instant review, differentiation, and analysis. Flow cell accommodates pressures up to 2,500 psi to permit operation at wellhead without altering pressurized state of sample.
|
 Particle Image Analyzer is offered with extended range kit.Malvern Instruments Ltd
Malvern Herefordsh WR14 1XZ United Kingdom
Mar 27, 2006
Based on digital image analysis and automated microscopy, Morphologi G2 measures particle size using circle equivalent diameter and employs variety of parameters for particle shape analysis. This enables determination and quantification of differences between particles. Extended range accessory kit, comprised of low magnification objective and wide field of view condenser, lends upper measurement limit of 3,000 microns to system.
|
 Dot Meters capture and adjust images with one button.UV Process Supply, Inc.
Chicago, IL 60614-4805
May 26, 2005 Equipped with ccDot engine and graphic display, X-RiteDot portable dot-analysis instruments provide digital screen ruling assessment, on-board video dot magnification, and dot shape analysis on any media. They adjust for plate background image and feature 14,000 dpi optics. This allows measurement of AM amplitude modulated screens from 85–250 LPI as well as FM frequency modulated screens as fine as 20 microns. Models include BASICDOT, PLATEDOT, COMBODOT, and PRINTDOT. |
 Image Analysis System measures particle shapes and sizes.Malvern Instruments Ltd
Malvern Herefordsh WR14 1XZ United Kingdom
Mar 07, 2005 Sysmex FPIA-3000 measures particles suspended in aqueous and non-aqueous liquid media. Using CCD camera, system produces images of each suspended particle. In standard configuration, it can characterize particles from 1.5–160 microns. High and low magnification options cover ranges 0.8–80 microns and 12–300 microns, respectively. Sample volumes as low as 0.5 ml can be used throughout, and every particle image is stored for future reference and analysis. |
 Image Analyzer suits column chromatography applications.Malvern Instruments Inc.
Southborough, MA 01772
Aug 13, 2004 Flow Particle Image Analyzer, Model FPIA-2100 provides information on particle size, shape, and distribution of packing materials for column chromatography. Digital image analysis helps trace non-spherical particles that regularly occur if operating pressure is raised too high. Instrument produces scattergram plots of size against shape, which provide method of fingerprinting materials, enabling visual comparisons to be made between samples. |
 Image Analysis System measures objects down to 1 micron.Optomax
Hollis, NH 03049
Jun 25, 2002 Sorcerer Image Analysis System features high resolution 1300 x 1030 pixel CCD camera that is compatible with compact petri viewer or optical microscope. Using macro-programming language to initiate measurement sequences, system links to Excel® and automatically transfers data to MS Access®, Oracle 9®, and other popular databases.
Sorcerer is suitable for particle size and shape analysis, porosity, spray droplet sizing, and corrosion analysis.
|
 Thermal Imaging System has accuracy to 2 degrees C.Ircon Inc.
Niles, IL 60714
Feb 19, 2002 Stinger Thermal Imaging System offers uncooled Focal Plain Array (FPA) 320 x 240 sensor, and provides on-line, radiometric thermal imaging. Real-time video captures data from up to 50 areas of interests at rates up to 60 frames per second. Test and playback features allow data to be captured, stored as image files, or exported. System includes Stinger camera with focusing lens, Windows® 2000 based computer, Image Analysis software, and connection cables. |