 At-Line Automation Analyzer targets food process industry.Brinkmann Instruments, Inc.
Westbury, NY 11590
Jun 23, 2008
Utilizing micro sample loops, overflow pipettes, pumps, valves, stirrers, and Dosinos®, Metrohm® ProcessLab analyses pH, acid value, chloride and vitamin C, all without operator intervention. It can be equipped with high-speed homogenizer for dissolution of solids as well as hot water to dissolve powders. Hermetical separation of electronics resists dust/liquids, while industrial PC and PLC driven controller allows for extensive communication within process environment.
|
Multiparameter Analyzers offer digital communications.Emerson Process Management / Process Liquid Division / Uniloc Division
Irvine, CA 92606
May 16, 2008
Rosemount Analytical® Model 1056-HT and 1056-DP are 4-wire, dual-input analyzers that feature, respectively, complete HART® and Profibus® DP digital communications. HART-enabled analyzer allows remote calibration, continuous monitoring of 4 live process variables, and configuration from AMS® Suite or DeltaV(TM) host applications, legacy DCS, or SCADA systems. Diagnostics allows plants to estimate life of in-process sensors and perform required maintenance on timely basis.
|
 Process Analyzer targets food industry.Brinkmann Instruments, Inc.
Westbury, NY 11590
Jul 11, 2007
Utilizing micro sample loops, overflow pipettes, pumps, valves, stirrers, and Dosinos®, Metrohm ProcessLab carries out pH, acid value, chloride, and vitamin C analyses, all without operator intervention. It can also be equipped with high-speed homogenizer for dissolution of solids as well as hot water to dissolve powders. Hermetical separation of electronics protects unit against dust and liquids. Industrial PC and PLC-driven controller allow for communication within process environment.
|
Turbidity Analyzer is suited for potable water plants.Emerson Electric Co.
St. Louis, MO 63136 8506
Jul 11, 2007
Available with universal ac-driven and 24 Vdc power supply options, Model 1056 is offered as single- or dual-input analyzer that measures turbidity, pH/ORP/ISE, conductivity, oxygen, chlorine, and ozone. Line-powered instrument features large high-contrast LCD display, intuitive menu screens, and 7 programmed languages. Four process variables or diagnostic parameters are displayed simultaneously from every screen, giving operators process information at a glance.
|
 Sensors are designed for industrial/municipal applications.Analytical Technology, Inc.
Oaks, PA 19426
Dec 20, 2006
Available in several mounting configurations, pH/ORP sensor utilizes sealed reference design where second glass pH electrode acts as reference element to protect sensor from chemical poisons. Electrode used for ORP measurement can be platinum or gold depending on process solution. Pre-amplifier encapsulated in body ensures stable readings in harsh environments, while sensor diagnostics alerts user in event of electrode breakage, or integral temperature sensor failure.
|
 In-Line pH Analyzer uses non-glass probes.IQ Scientific Instruments, Inc.
San Diego, CA 92127
Mar 10, 2003 Waterproof Series IQ500 processLab™ accepts silicon chip sensor probes as well as glass sensor probes. Designed for in-line continuous process monitoring applications, unit features 4 relays that can be set for ON/OFF, Pulse Length, Pulse Frequency, or Alarm mode and four 0/4-20 mV optically isolated, analog outputs that can be driven by pH, mV, or temperature. Large 5 ˝ in. backlit LCD displays pH, temperature, date/time and status of all relays and outputs. |
 Intelligent pH Meter has built-in microprocessor circuit.B & K Precision Corp.
Placentia, CA 92870
Dec 05, 2002 Model 760 hand-held, battery-powered, multifunction pH, mV/Temperature instrument is PC compatible for use in laboratories and field. With LCD display, unit measures pH from 0–14, mV from -1999 to 1999, and temperature compensation for pH measurement from 0–100°C. Available with various probes and software, plug and play unit offers Data Hold feature and can record maximum and minimum readings with recall. |
 Analysis, Cleaning, Calibration System is fully automated.Mettler-Toledo Process Analytics
Bedford, MA 01730
Oct 23, 2002
EasyClean 350 fully automates in-line analysis of pH, dissolved oxygen, and conductivity in liquid processes. It carries out all routine maintenance relative to cleaning and calibration without skilled maintenance personnel. Self-monitoring diagnostics immediately alert process operators or maintenance personnel to functional problems. Designed for use in high-throughput liquid processes, system suits chemical, pharmaceutical, and industrial wastewater applications.
|
 pH Meter offers pH, ORP, and temperature measurement.Cole Parmer Instrument Co.
Vernon Hills, IL 60061
Jun 17, 2002 Less sensitive to electronic noise, OAKTON pH 510 benchtop meter provides stable, repeatable readings. It includes quick reference, slide out instruction card, dual display/hold function that freezes readings, and memory storage that stores and recalls up to 50 measurements. Water-resistant membrane keypad protects meter from accidental spills. Meter is available with manual or automatic temperature compensation. |