 Gas Sampling System is suited for HVAC applications.Mine Safety Appliances Co.
Pittsburgh, PA 15230
Oct 31, 2007
Using common set of analyzers for up to 32 locations, MultiGard System detects CO, NO2, O2, and refrigerant gases and delivers sample to as many as 4 sensors or analyzers. Fixed system, configured via front touch-screen panel display, directly connects to Allen-Bradley's Ethernet or Data Highway Plus(TM) networks. Time sharing of central analyzers minimizes installation, operational, and maintenance expenses by eliminating multiple systems.
|
Freezing Point Osmometer measures 96 samples in 35 minutes.Advanced Instruments, Inc.
Norwood, MA 02062
Oct 10, 2007
Designed to automate laboratory work and reduce time for cell culture process optimization, Multi-Sample 20G Osmometer incorporates 8 computer controlled osmometers and robotic sample handling system, all enclosed in safety cabinet. Features include accurate osmolality measurement in clinical, industrial, and research settings, random-access, data export, fully programmable system controls, LIMS user interface, and barcode reader to provide additional input options.
|
 Gas Analysis Sampling System needs no routine maintenance.Perma Pure Inc.
Toms River, NJ 08754
Jun 28, 2006
Suited for continuous emissions monitoring, GASS(TM)-2040 prepares gas samples for analysis. It uses Nafion® technology to remove acid mists, coalescent liquids, water, and particulates without altering concentrations of analyte gases. Unit, which features NEMA-4x stainless steel enclosure and integral stack mounting capability, connects directly to probe and dries sample completely before transporting it to ground. Drying is continuous, self-regenerating process.
|
 Gas Analysis Sampling System offers stack mounting option.Perma Pure Inc.
Toms River, NJ 08754
Mar 10, 2006
Housed in NEMA 4X rated enclosure, GASS(TM)-2040 prepares gas samples for analysis, removing acid mists, coalescable liquids, water, and particulates without altering concentrations of analyte gases such as CO, CO2, HCl, NOX, O2 and SO2. It processes samples containing 50% water at rates of up to 25 L/min, removing particulates as small as 1 µm, and reducing water content to dew point of -25°C. Heated coalescing filter with automatic drain removes acid mists before drying.
|
 Stream Selector System facilitates sample analysis.Swagelok Company
Solon, OH 44139-3492
Dec 01, 2005
Modular Swagelok® SSV series delivers representative sample from multiple sample streams to one analyzer. This ANSI/ISA 76.00.02-compatible stream selector system controls each stream by double-block and bleed (DBB) module, which eliminates cross contamination and maintains sample integrity. DBB module also performs actuation functions. To provide consistent outlet flow, system features integrated flow loop that also streamlines sampling and purging.
|
 Sample Divider extracts representative samples.Retsch, Inc.
Newtown, PA 18940
Aug 18, 2005 Rotary Tube Divider, Model PK 1000, extracts 1 or more samples from granular or powdered substances with feed size up to 10 mm. Introduced to divider through vibratory feeder, product passes into cone where tube rotates at constant speed of 50 rpm. With each rotation, portion of sample is deposited through slot into sample collector. Dividing ratio and volume of extracted sample are determined by width of slot, which can be adjusted from 0-73 mm. |
 Gas Sampling System is probe mounted.Perma Pure Inc.
Toms River, NJ 08754
Jul 22, 2004 Designed to prepare wet, hot, and dirty stack gases for analysis, 1640 Mini-GASS (Gas Analysis Sampling System) allows users to accurately monitor smoke stack emissions. Gas conditioning system extracts sample gas via integrated sample probe and passes it through series of filters, scrubbers, and dryers. Housed in stainless steel cabinet, components remove water, acid mist, and ash without altering concentrations of gases to be analyzed. |
 Sampler suits water pollution surveillance and control.BVS, Inc.
Honey Brook, PA 19344 0250
Jul 14, 2004 Protected with powder coat finish, free-standing PPER-400 Automatic Sampler uses flooded-suction concept of operation to ensure that samples retain solubility. All circuits are relay interfaced, and ground fault indicator system relates safe/unsafe conditions. Standard sample lift is 40 ft, adjustable up to 80 ft with pressure supplied by optional split-phase, capacitor-start, diaphragm compressor with solid-state electronic unloader or clean air supply. |
Sampling Chamber characterizes optical substrates.Ocean Optics, Inc.
Dunedin, FL 34698
Aug 05, 2003 Variable-angle Reflection Sampling System couples to spectrometers and light sources to measure spectral reflectance of optical substrates from 200–1,100 nm at angles of incidence from 10° to 50°. Modular, optomechanical device has black anodized stainless-steel chamber with 2 ports for SMA 905-terminated optical fibers. Its 3-point fixed surface mount retains sample position, while thumbscrew locks optical assembly at fixed angle. |
 Autosampler extends capabilities of GC or GC/MS.CDS Analytical, Inc.
Oxford, PA 19363 0277
Mar 27, 2003 Model AS2500plus Pyrolysis Autosampler performs thermal desorption and pyrolysis on same sample. Unit handles up to 36 samples and can be programmed through handheld controller or Windows® based software for unattended operation. It can be programmed for temperature rates from 0.01°C/min to 20,000°C/sec and max temperature of 1300°C. Difficult samples such as polymers, adhesives, paint, rubber, tobacco, packaging, inks, and textiles can be analyzed. |
 Passive Samplers utilize 2,4-DNPH chemistry.SKC, Inc.
Eighty Four, PA 15330 9614
Mar 26, 2003 UMEx Passive Samplers collect formaldehyde and other aldehydes in ppb and ppm range. Polypropylene units clip to worker's collar for personal sampling from 15 min to 8 hr, or are placed in appropriate location for indoor air sampling up to 24 hr for formaldehyde. No sample pump is needed. Each incorporates blank section in addition to active sampling section. On/off sliding cover starts and stops sampling. |
 Sample-Handling System consists of modular components.Swagelok Company
Solon, OH 44139 2764
Feb 07, 2003 Modular platform components consist of surface mounts, including valves and filters, plus substrates and manifolds to assemble process analyzer and sample-handling systems. System meets requirements of ANSI/ISA 76.00.02 specification for 1.5 in. footprint. Configurator software allows user to place, define, and connect components on computerized layout grid. It identifies additional flow connectors necessary to build fluid system and generates bill of materials and assembly diagram. |
 Sample Dilution/Injection System suits GPC chromatography.Polymer Laboratories, Inc.
Amherst, MA 01002
Feb 01, 2003 Suited for Gel Permeation Chromatography (GPC), PL XT-R is based on robotic platform and integrates sample preparation and autosampling functions. Product supports all GPC chromatographs operating in temperature range from 30-220°C. Up to 96 sample-filled vials are accommodated in blocks in X-Y array. Solvent-filled vials are subjected to controlled heating and magnetic stirring. System includes robotic arm dispenser, heated injection valve, and heated transfer line. |
 Sample Divider extracts representative samples.Retsch, Inc.
Irvine, CA 92614
Jan 29, 2003 Model PK 1000 Rotary Tube Divider extracts samples from granular or powdered substances with feed size up to 10 mm. Introduced to divider through vibratory feeder, product passes into cone where rotary tube rotates at constant speed of 50 rpm. With each rotation, portion of sample is deposited by rotary tube through slot into sample collector. Dividing ratio and volume of extracted sample are determined by width of slot, which can be adjusted continuously from 0-73 mm. |
 Automatic Sampler demounts without process interruption.Bristol Equipment Co.
Yorkville, IL 60560
Dec 20, 2002 ISOLOK® SAL-25 Sampler Series handles liquids and slurries with entrained solids up to 3/8 in., drawing measured samples of 25 cc/cycle on command from electrical or pneumatic controls. Actuated by double-acting air cylinder, products tap process streams moving through pipes or vessels pressurized up to 300 psi. Integral process-isolation valve allows removal of sampler for service without de-pressurizing process being sampled. Sample path always remains enclosed. |
 On-Line Effluent System monitors up to 5 process streams.Spectro Analytical Instruments Inc.
Fitchburg, MA 01420 6093
Oct 21, 2002 On-Line Sampling System provides automated, multi-elemental analysis to assist volume waste producers where multiple effluent streams must be monitored and controlled on 24-hour basis. Features include time-controlled startup and shut-down and built-in self-monitoring and diagnostic functions. Remote access/control functions are available using TCP/IP based SPECTRONET™ communications option, programmable for multi-level error handling and traceable sampling. |
 Sampler captures uniform samples of medium-viscosity fluids.Bristol Equipment Co.
Yorkville, IL 60560
Oct 15, 2002 Actuated by compressed-air cylinder, ISOLOK® Series MSC Sampler taps process streams moving through pipes or vessels pressurized up to 200 psi. Design keeps sample path completely enclosed to avoid spillage waste, contamination of sample or process, and material exposure to personnel. All metal parts are type 316 SS with polished finish. Moving parts are hardened with industrial chrome for extra wear resistance. Sample containers range from 125 ml to 4 L. |
 Autosampler provides unattended sample analysis.TA Instruments
New Castle, DE 19720
Oct 11, 2002 DSC Autosampler for Q Series DSC modules has 50 sample, 5-reference-pan carousel tray that allows round-the-clock sample analysis. Autolid arm manages operation of DSC cell's lids and heat shield for repeatable thermal isolation of cell. Sample arm controls loading and unloading of sample and reference pans in sequential or random order. Optical sensor guides sample arm, ensuring precise pan placement and automatic calibration of system. |
Edge Compressor/Sampler suit UWB communication applications.Picosecond Pulse Labs, Inc.
Boulder, CO 80301
Sep 03, 2002 Using Non Linear Transmission Line technology, Edge Compressor transforms input signal by compressing leading edge and reducing its risetime. Output rise times are as short as 4 ps. Unit offers edge compression to 70 ps and repetition rates greater than 20 GHz. Sampler features 100 GHz bandwidth, 3 ps aperture, 10 G sample/sec sampling rate, and 1.0 mm connectors. |
 Portable Air Monitor includes downloading software.SKC, Inc.
Eighty Four, PA 15330 9614
Apr 25, 2002 Microprocessor-based HAZ-DUST EPAM-5000, for environmental and indoor particulate monitoring, combines light-scattering dust monitoring with inline 37 mm filter cassette for concurrent gravimetric samples. It samples particles from 0.1 to 100 micrometers, using adjustable flow rate from 1.0 to 5.0 L/min, and reads particles from 0.001 to 20.0 mg/m3. Interchangeable size-selective sampling heads allow PM 1.0, PM 2.5, or PM 10 monitoring. |