Compressor Chiller is available from 30-180 tons.McQuay International
Minneapolis, MN 55440
Oct 10, 2007
McQuay air-cooled scroll compressor chiller is available with R-410A refrigerant that is chlorine-free and has no ozone depletion potential. With up to 10.3 EER at full load and up to 14.7 EER at part load, chiller meets or exceeds ASHRAE Standard 90.1 for energy efficiency. McQuay Open Choices(TM) feature allows MicroTech II® controls to integrate into building automation systems using open, standard protocols such as LonTalk®, BACnet® or Modbus®.
|
Precision Cooling System is offered in 3 upflow models.Emerson Network Power
St. Louis, MO 63136
Sep 14, 2007
Available in capacities of 28, 35, and 42 kW, Liebert DS(TM) systems provide support for applications that require cooling delivered from top of unit (upflow). Use of digital scroll compressors allows capacities to adapt to room condition changes as small as ±1°F and ±1% RH, and Paradenser condenser system permits use of green refrigerants. Liebert iCOM(TM) control system, which provides diagnostic and maintenance support, also enables multiple units to communicate and work together.
|
Vortex Tubes are suited for high-temperature applications.EXAIR Corporation
Cincinnati, OH 45249-1621
Jul 10, 2007
High Temperature Vortex Tubes convert ordinary supply of compressed air into one hot stream and one cold stream for spot cooling applications in environments up to 392°F. Compressed air is sole source of power, eliminating use of chemicals and refrigerants, and cold air temperatures are adjustable from -50°F to ambient. With cooling capacities of 135-10,200 BTU/hr, stainless steel tubes have no moving parts and offer total airflow of 2-150 scfm @ 100 psig inlet air pressure.
|
 Air Conditioning System provides spot cooling for workers.Aqua Products Co., Inc.
Newberry, SC 29108
Jun 20, 2007
Hydro-Star Spot Cooling System utilizes Superflex fittings, which adjust to let individual employees determine direction of cool air flow. Comprised of Glycol Chiller (Model DCP) and commercial, high-pressure, water-cooled air handler, system provides stream of cool, dry air exclusively to each employee at their work station via 3 in. air line. System can also take 100% outside air, cool by 15 to 25°F, and dehumidify it in one pass.
|
PCU and Battery Cooling System suit hybrid vehicles.DENSO Corp.
Aichi 448-8661 Japan
Jun 19, 2007
Including boost converter that raises main battery voltage (288 V) up to maximum system voltage (650 V), Power control unit has 2 inverters to convert dc into ac for main traction motors. PCU can be used in hybrid vehicle systems with different output levels by changing number of stacked power devices and cooling tubes. Battery cooling system uses cooled air from cooling unit of rear air conditioning system and cabin air to cool main battery.
|
Truck Air Conditioning System works while engine is off.Behr GmbH & Co. KG
Stuttgart 70469 Germany
May 09, 2007
Integrating with OEM auxiliary HVAC systems, ducts, and controls, NIA/C No-Idle System provides air conditioning to heavy-duty truck cabins while engine is turned off. It features externally mounted compressor/condenser for quiet sleeping environment, maintains comfortable cabin temperatures day or night, and offers one-button starting. Compliant with no-idle regulations, system cuts fuel consumption, engine wear, and emissions.
|
 Air Conditioners feature health-enhancing capabilities.Panasonic Co.
Secaucus, NJ 07094
May 04, 2007
Models CS18GKF, CS-C24GKF, and CS-C28GKF employ E-ion Air Purification System with patrol sensor, which monitors, detects, and collects dirt in air - even if unit is not in operation. Such technology serves to neutralize airborne bacteria and mold as well as various air pollutants/odors. Air conditioners also incorporate Super Tropical Rotary Compressor and Blue Fin Condenser technology for reduced heating and corrosion resistance, respectively.
|
 Air Conditioners feature condenser coil protection.Rittal Corporation
Springfield, OH 45504
Apr 30, 2007
Suited for electronic enclosures, TopTherm Plus Air Conditioners incorporate condensate evaporator to eliminate risk of overflowing external condensate collectors. Condenser coils feature RiNano protective coating, which offers water-, dirt-, and oil-repellent properties and promotes constant cooling performance. Offered in roof- and wall-mount models with 1,000-13,600 BTU cooling capacities, units are constructed with separated, insulated internal and external cooling chambers.
|
All-Electric HVAC System is powered by truck battery.Dometic Corp., The
Elkhart, IN 46516
Apr 20, 2007
Run on 12 V power from truck batteries, auxiliary cooling and heating system consists of 7,000 or 10,000 BTU split or self-contained air conditioning system, DC/AC inverter, alternator, and optional shorepower pass-through. Quiet operation is ensured because no separate diesel auxiliary power unit is required. Batteries are kept fully charged whenever truck is running, and system meets federal, state, and local clean-air requirements.
|
 Evaporative Air Conditioners are environmentally friendly.Scott Brothers Ltd
Cheshire, CW10 9LT United Kingdom
Mar 27, 2007
Operating with windows and doors open, Bioclimatic Convair Appliances provide cooling without refrigerant chemicals and end-of-life disposal problems. Using less energy than one 100 W light bulb, units are lightweight so they can be repositioned. Air conditioners come in white and titanium to suit varying design requirements.
|
Air Conditioning System targets marine applications.Dometic Corp., The
Elkhart, IN 46516
Feb 27, 2007
Self-contained, water-cooled Turbo Series includes multiple models ranging from 6,000-16,000 btu. Design incorporates positive-flow composite condensate drain pan that minimizes standing water, and centrifugal enclosed-motor HV blower that can be rotated up to 270° with single-screw adjustment for discharge in any direction. Built-in isolation mounting system minimizes vibration and noise.
|
Cold Gun minimizes heat build-up in machining operations.EXAIR Corporation
Cincinnati, OH 45249-1621
Feb 01, 2007
Producing stream of 20°F air, High Power Cold Gun is suitable for continuous use without possibility of freezing up. Stainless steel vortex tube converts ordinary supply of compressed air into cold air, while flexible ball and socket hose directs cold air to point where heat is generated. Eliminating filtration, clean-up, and disposal of liquid coolants, gun is suited for laser cutting, tool sharpening, drill and cutter grinding, milling, drilling, and band sawing.
|
Cooling Unit saves energy with variable airflow.American Power Conversion
West Kingston, RI 02892
Feb 01, 2007
Placed next to heat source in data centers and small computer rooms, InfraStruXure® InRow(TM) RP supports power densities up to 70 kW per rack when used with hot air containment systems and comes in chilled water- and refrigerant-based designs. Varying cooling capacity with heat load requirements conserves energy during partial load conditions, and integrated humidifier provides room-level moisture control. Control algorithm enables real-time capacity monitoring.
|
Rooftop AC Units feature plug and play design.Daikin Europe N.V.
Oostende 8400 Belgium
Jan 24, 2007
Built around scroll compressors, R-407C operated UAT(Y)P Series includes heat pump and cooling only models with capacities of 16.7-109.6 kW and 17.3-121.6 kW, respectively. Operating temperatures are 20-46°C in cooling mode and -15 to 20°C in heating mode. Belt-driven fans allow adjustment of air volume and static pressure as required. Featuring electronic remote control with 15 hr delay timer, units are suited for supermarkets, warehouses, factories, and restaurants.
|
Air Conditioning Unit is designed for marine industry.Dometic Corp., The
Elkhart, IN 46516
Dec 22, 2006
Marine Air SVCD30 is supplied in seawater-cooled, framed package with single 30,000 BTU compressor/condenser and dual 16,000 BTU evaporator/blower assemblies mounted back-to-back on one chassis. Self-contained for limited-space applications, this 30,000 BTU unit draws return air from 1 or 2 compartments across both evaporator coils and ducts discharge air to 2 or more spaces. Stainless-steel chassis and Heresite coating for exposed components lend to corrosion resistance.
|
Air Conditioning Unit targets salt-air marine environments.Dometic Corp., The
Elkhart, IN 46516
Dec 20, 2006
Developed for jack-up boats and barges, 14,000 BTU air-cooled Model SSA14K includes compressor, evaporator, blower, and other mechanical and electrical components on single chassis that is bolted directly to deck. Built-in return-air and discharge-air plenums cool compartment directly below without duct runs. Chassis and enclosure are stainless steel, while condenser and other components are Heresite-coated for additional corrosion protection.
|
Cooling Unit is suited for wiring closets and server rooms.American Power Conversion
West Kingston, RI 02892
Nov 21, 2006
Capable of providing up to 7 kW of cooling capacity, InfraStruXure® InRow(TM) SC has modulating capacity control and variable speed fans providing required amount of cooling even in lightly loaded situations. Network manageability feature via web, SMNP, and Telnet helps in predictive failure notification while hot-swappable fan modules minimize mean-time-to-recovery. Self contained 12 in. wide (half-rack) solution helps measure and report cooling capacity for real-time capacity management.
|
Cooling Modules come in ceiling and rack mount models.Emerson Network Power
St. Louis, MO 63136
Oct 23, 2006
Available in nominal 20 kW rating, Liebert XDO overhead, ceiling-mounted fan coil draws hot air from hot aisle and exhausts cool air vertically down into cold aisle. Mounted on top of rack or suspended from ceiling, Liebert XVD vertical fan coil offers nominal 10 kW rating. It draws hot air from hot aisle or rack and exhausts cold air into cold aisle where equipment air intakes are located. Both use waterless pumped refrigerant technology, eliminating potential for water damage.
|
Fan Tray features cross-flow cooling technique.New Age Fans
Fairfield, NJ 07004
Sep 13, 2006
Baffled fan tray utilizes cross-flow cooling fan and features adjustable depth as well as local and remote alarms. Due to its unique configuration, tray requires only 75 cfm. This low-wattage (6 W), 19 in. rack-mount fan tray assembly is CSA-, NEBS-, and UL-compliant. Applications include cooling of rack- and cabinet-mounted electronic equipment in telecommunications, commercial, military, and electronic industries.
|
Air Conditioners utilize nanotechnology.Rittal Corporation
Springfield, OH 45504
Aug 31, 2006
Suited for use in industrial environments where dust and oil-laden air can clog condenser coils, TopTherm air conditioners are manufactured with condenser coil designed with RiNano protective coating. Comprised of different classes of nanoparticles, RiNano forms solid, homogeneous bond with condenser surface. This produces glass-like surface layer that repels water, dirt, and oil, promoting long-term constant cooling performance.
|