Turbine Flowmeters are suited for large pipe metering.
April 23, 2010 -
Suited for pipeline diameters from 4 in. upwards, Series 5000 flowmeters can be installed/removed using suitable valve, ensuring flow line continues to remain under pressure. They can be fitted with different, interchangeable rotor assemblies and are available with wide range of electronic signal conditioning and readout instruments, which can be mounted locally or remotely at distances up to 3,000 m using preamplifier. Units suit oil, gas, and general industrial flow metering.
(Archive News Story - Products mentioned in this Archive News Story may or may not be available from the manufacturer.)
Original Press release
Filton Process Control Engineering
Haywards Heath, West Sussex
RH16 1BP, , United Kingdom

Turbine Flowmeter Is Ideal for Large Pipe Metering
A new range of insertion turbine flowmeters for applications where installation and removal from the pipeline without interruption to flow, is more important than extreme accuracy, are now available from FILTON PROCESS CONTROL. Series 5000 flowmeters are simple to install and remove and are particularly suitable for large pipelines, where the cost of inline meters can be prohibitive.
These low cost flowmeters can be installed and removed through a suitable valve while the flow line continues to remain under pressure. In addition to low cost and optimum flexibility, they provide wide rangeability and improved linearity.
The principle of operation is as fluid flows through the turbine assembly it causes the blades of a freely supported rotor to turn at a speed directly proportional to the flow velocity. A pick-up assembly fitted into the insertion stem immediately above the rotor detects the passage of each blade tip and generates a sine wave output, the frequency of which is proportional to the turbine rotor speed and hence velocity and thereby flow rate. This signal may then be used in conjunction with local or remote signal conditioning electronics a comprehensive range of which is also available.
The flowmeters can be fitted with different, interchangeable rotor assemblies and are available with a wide range of electronic signal conditioning and readout instruments. Readout equipment can be locally mounted, or remotely when a preamplifier is used, and distances up to 3000 metres can be accommodated. When used in conjunction with a ball valve, the metering head retracts fully into the housing so they can be removed without interrupting fluid flow.
Series 5000 flowmeters are ideal for pipeline diameters from 4" upwards and meet most installation requirements for oil, gas and general industrial flow metering operations.
|
User comments about this story
Flow Meter For dissle transfer
Dear sir/madam
How are you, Wishing you a great time of the day!
As surf on your website we found turbine flow meter could you please send more information about transfer gasoline (Gas Oil) form tanker machine 8000 Liter to underground Storage more than 32000 m/3 in high speed range over than 1000 l/m The size of pipe for transfer is 8”
By Amir Hossein Yavarian on Mar 18, 2012 14:37
Reply to this comment
Replies to this comment:Diesel Flow Meter
Amir,
Thanks for your enquiry.
Please advise the temperature and pressure at operating conditions.
Do you require fixed or retractable unit?
If retractable will you insert it through a valve?
What process connections? Screwed or flanged?
Please reply direct to my e-mail sfc@filton.com
Many thanks
Steve
By Stephen Filmer-Cox on Mar 19, 2012 11:34
|
|
|
|