Light Source matches light level of single star.

Print | 
Email |  Comment   Share  
Light Source matches light level of single star.
Light Source matches light level of single star.

Click Here to Enlarge Picture

April 15, 2004 - With 0.0001–100 cd/m luminance range, USS-1200V-LL Starlight Uniform Source System suits calibration of low-light level imaging devices and systems. Satellite sphere illuminator, with external halogen light source and motorized variable attenuator, controls illumination levels. System includes 12 in. dia integrating sphere with 4 in. dia exit port and 2-part filter system comprised of bandpass filter-wheel and neutral-density filter. It may be directly or remotely controlled.

(Archive News Story - Products mentioned in this Archive News Story may or may not be available from the manufacturer.)
Original Press release

Labsphere, Inc.
P.O. Box 70A
North Sutton, NH, 03260 0070
USA


New Low Light Uniform Source System Matches the Level of Light from a Single Star

NORTH SUTTON, NH - Labsphere, Inc. announces the USS-1200V-LL “Starlight” Uniform Source System for calibrating extremely low light level imaging devices and systems. The new Starlight Uniform Source System is specifically designed to provide spectral irradiance levels comparable to those of a single star shining on the Earth’s surface, featuring a luminance range of 0.0001 – 100 cd/m. This is necessary for the calibration and test of such equipment as night vision systems, aircraft displays, and low light level targeting systems.

The Starlight System features a satellite sphere illuminator with an external halogen light source and a motorized variable attenuator for precise control of illumination levels. Light from the satellite sphere enters the main sphere by passing through a two-part filter system: a bandpass filter-wheel permits selection of a specific spectral channel, while a neutral-density filter determines the system’s irradiance range.

The system can be operated directly, from front-panel controls, or through Labsphere’s standard Uniform Source System software. This software permits remote control of the lamp power supply, variable attenuator, and optional detector multiplexer. It also automatically corrects detector readings using programmable calibration factors, displaying the readings in both graphic and numeric format.

The Starlight System includes a 12” diameter integrating sphere with a 4” diameter exit port. The sphere is coated with Labsphere Spectraflect, providing an irradiance uniformity of greater than 98%.

About Labsphere: With 25 years of experience, Labsphere, Inc. is the world leader in light measurement, producing best-in-class calibration systems and components. Products include uniform light sources to calibrate imaging devices and camera systems in the visible and IR; light measurement systems for lasers, LEDs, and traditional light sources; and reflectance standards for calibrating spectroscopic measurement systems. Labsphere also provides systems and components to OEMs in numerous industries, including spectroscopy, laser diode test and measurement, semiconductor, and medical.
Print | 
Email |  Comment   Share  
Contacts: View detailed contact information.


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
To submit comment, enter the security code shown below and press 'Post Comment'.
 



 See related product stories
More .....
Dont hunt for stories like this.
Let Product News Come to You!
Get a Free Subscription
to Product News Alerts.
Edit Story Categories
Start Your Free
Subscription to
Industry Market Trends.
 See more product news in:
Optics and Photonics
Vision Systems
 More New Product News from this company:
Lamp Standards provide light measurement system calibration.
Integrating Spheres offer configuration flexibility.
Spectral Lamp-Measurement System handles low-power sources.
Uniform Source System calibrates visible to IR spectrum.
More ....
 Other News from this company:
Labsphere's Spectralon Reflectance Standards for Equipment Calibration
Labsphere Recoating Services Go Mobile
Labsphere Launches Online Shop
Labsphere's Fluorescent Spectral Lamp Measurement System Evaluates Lamp Efficiency
Labsphere Delivers Fourth Life Test Station to Major LED Manufacturer
More ....
 Tools for you
Watch Company 
View Company Profile
Company web site
More news from this company
E-Mail Story
Save Story
Search for suppliers of
Light Sources
Join the forum discussion at:
The Factory Floor


Home  |  My ThomasNet News®  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2012 Thomas Publishing Company
Terms of Use - Privacy Policy



Error close

Please enter a valid email address