Quantcast
 
Search for: Search what?
Nov 24, 2009  
 Sections
Latest New Product News
Industry Market Trends
Green & Clean News
Association & Government News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
Browse Categories
Browse Companies
Mobile Edition
PR Resources
Licensing
Advertising
How to Write an effective Press Release
Trade Associations
Small Business Support
MEP
Advertisement
Tester measures intrinsic viscosity of PET polymers.
Tester measures intrinsic viscosity of PET polymers.

Click Here to Enlarge Picture

Tester measures intrinsic viscosity of PET polymers.


May 9, 2008 - Eliminating environmental hazard of handling and disposal of toxic solvents, Davenport(TM) PETPlus determines IV of moisture-sensitive PET polymers as well as degradation factor, and provides mean and standard deviation for each batch. Instrument is supplied with integral nitrogen regulation valve for pressure adjustment when testing different materials. Able to store up to 600 test results, microprocessor-controlled stand-alone system offers temperature control to +0.1°C.

(Archive News Story - Products mentioned in this Archive News Story may or may not be available from the manufacturer.)

 See related product stories
Centrifuge offers feature set for productivity and safety.
Testing Instrument determines IV of moisture-sensitive PET.
Smart Viscosity Sensor comes packaged as threaded bolt.
Viscosity Test Cup features internal timing pins.
Starter Kit tests viscosity sensors via computer.
 See more product news in:
Sensors, Monitors and Transducers
Test and Measuring Instruments
 Tools for you
del.icio.us DIGG  
Facebook Reddit
StumbleUpon Twitter
Print This Page E-Mail Story
Watch_Company  Save Story
View Company Profile
Company web site 
More news from this company

Advertisement
More Tools and information
Search for suppliers of
Viscosity Testers
Join the forum discussion at:
 Tools of the Trade
 Newsletters
Your Gateway to a Fast Changing World
Product News Alerts
Receive similar stories and other customized news to keep you in the know on the products shaping industry.
Subscribe Free Today
Subscribe   View Sample

Industry Market Trends
Has Got It
  • Latest developments
  • Trends
  • Best practices
  • Opinions & Commentary
Get Ahead. Get IMT.
Subscribe Free Today
Subscribe   View Sample
 See more related product stories:
Viscometer System measures dilute polymer solutions.
Spindle Coupling System aids viscosity testing process.
Viscosity Sensor features USB connectivity option.
Viscosity/Temperature Sensor offers USB option.
GPC/SEC System offers multiple detection technology.
Viscosity Sensor withstands immersion in fluid stream.
Test System performs consistent gel analysis.
Viscometer uses tuning fork vibration method.
Soft Solids Tester is available with custom vane spindles.
Disposable Spindles save cleanup time.
Viscosity Meter offers one-button operation.


Lloyd Instruments Launches Unique PET Intrinsic Viscosity Test Instrument


LARGO, FL-- Lloyd Instruments, a unit of AMETEK Measurement & Calibration Technologies, has launched the Davenport(TM) PETPlus Intrinsic Viscosity Measurement Instrument. This new compact stand-alone instrument offers significant benefits for determining the intrinsic viscosity (IV) of moisture-sensitive PET polymers, avoiding both the costs and the environmental hazard of handling and disposal of toxic solvents. The PETPlus also measures the degradation factor and provides the mean and standard deviation for each batch.

The PETPlus is supplied with a convenient integral nitrogen regulation valve for easy pressure adjustment when testing different materials. Requiring only power and a pressurized nitrogen supply, the instrument can be operated in stand-alone mode or used in conjunction with NEXYGENPlus PET, AMETEK's powerful new dedicated data analysis software package for the IV measurement of PET polymers. A user-friendly training mode is included as standard to simplify operator instruction.

Polymers can be tested by the PETPlus at virtually all stages of the production process to provide greater overall control. Tests can be completed in as little as 20 minutes on incoming resin, powder, dry granules, molten polymer, pre-forms, bottles, films and even re-ground material to eliminate scrap. Rapid testing at the different stages can be carried out using ancillary equipment for controlled sample collection and preparation. The instrument's compact construction occupies significantly less bench space than earlier models and makes it easier and quicker to load samples.

The microprocessor controlled stand-alone system provides high accuracy measurements, temperature control to + 0.1°C and storage of up to 600 test results. A backlit LCD displays instructions for the test in a variety of languages as well as the results. An RS-232 interface allows connection to a computer for downloading of results or for fully automated software control using NEXYGENPlus PET.

The PETPlus Intrinsic Viscosity Measurement Instrument uses a well established unique solvent-free method for routine IV measurement of PET. Molten PET is extruded through a calibrated die by nitrogen gas under pressure, and the LVDT probe movement against time is recorded and displayed. The system measures the optimum flow rate and calculates intrinsic viscosity. The procedure used ensures that reliable, accurate and repeatable results are easily obtained and checked against standard polymers.

A comprehensive range of sample preparation equipment including vacuum pumps and polymer dryers are available to ensure correct sample drying conditions for the instrument. By using the Quick Test Polymer Chip Grinder, the material can be ground to a fine powder to ensure drying within just 50 minutes. A Polymer Chip Transfer Vessel is available to carry dried PET directly from the process dryer to the PETPlus for instant testing.

For more information, contact AMETEK Measurement & Calibration Technologies, 8600 Somerset Drive, Largo, FL 33223. Tel: 727-536-7831. Fax: 727-539-6882 or from the Lloyd Instruments web site, www.lloyd-instruments.com.

Lloyd Instruments is a unit of AMETEK Measurement & Calibration Technologies, a division of AMETEK, Inc., a leading global manufacturer of electronic instruments and electromechanical devices with 2007 sales of more than $2.1 billion.

CONTACT: Rich Brown (518) 689-0222


Contacts:

General Information:
Rich Brown
USA
Phone: 518-689-0222

Company Information:
Name: AMETEK Test & Calibration Instruments
Address: 8600 Somerset Dr.
City: Largo
State: FL
ZIP: 33773
Country: USA
Phone: 800-527-9999
FAX: 727-539-6882
http://www.chatillon.com


More New Product News from this company:
Temperature Calibrator uses dynamic load compensation.
Data Logging Software suits ASM-800 signal multi-scanners.
Graphic Display Module operates from 9-32 Vdc.
Shear Cell is designed for texture analysis.
Digital Force Tester is lightweight and portable.
Multi-Purpose Calibrator accommodates range of uses.
Dry Block Temperature Calibrators offer radial homogeneity.
Process Gauges feature all-welded gauge and diaphragm seal.
Flash Point Tester features continuously closed cup design.

Other News from this company:
New! - Jofra Handheld Pressure Calibrator
ATEX Certification for JOFRA Industrial Pressure Indicators



Click here for copyright permissions!
Copyright 2009 Thomas Publishing Company


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
 

Category Advertisements




ThomasNet News Advertisers
Custom Metal Filters www.yankeewire.com
Custom filters and strainers in stainless steel and most alloys to OEM specs




Home  |  My ThomasNet News  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2009 Thomas Publishing Company
Terms of Use - Privacy Policy