Heaters prevent pipes from freezing.
Heaters

Heaters prevent pipes from freezing.

Able to heat pipes in high altitudes and cold climates, Spiral heaters are available with different heating element designs, including single and multi-layer etched circuits and single and multi-layer wire wound circuits. Single, multiple, and variable watt densities can be designed into spiral heaters to suit specific application needs. Dielectric substrate materials available include silicone,...

Read More »
Induction Heating Equipment also quenches and cools parts.
Heaters

Induction Heating Equipment also quenches and cools parts.

IHScanner vertical scanning system has solid state power supply, dual spindle heat treating system, and part quenching and recirculating components. It is capable of heat treating cylindrical parts from 0.38 to 1.00 in. dia and up to 17 in. in length. It is available in power ratings from 25 to 100 kW and frequencies from 25 to 200 kHz. System is shipped ready to operate, requiring only 3-phase,...

Read More »
Switches and MOSFETs conserve space in digital devices.
Switches

Switches and MOSFETs conserve space in digital devices.

Housed in Teeny(TM) SC70-6 package, MIC94060 and MIC94061 smart-load switches offer 0.100 Ohm on-resistance (max). Simple P-Channel MOSFETs MIC94052 and MIC94053 offer 0.084 Ohm (max) on-resistance and allow more than 2A continuous current. Simple 4-terminal, P-Channel MOSFETs housed in SOT143-4 package, MIC94050 and MIC94051 offer 0.160 Ohm (max) on-resistance. Housed in SC-70 package, MIC94060...

Read More »
Cooling System offers cooling rate to 140°C/min.
Water Coolers

Cooling System offers cooling rate to 140°C/min.

Liquid Nitrogen Cooling System (LNCS) is designed for use with Q Series Differential Scanning Calorimeters (Q1000, Q100). It delivers low temperature performance down to -180°C and can operate up to 550°C. Unit provides instantaneous cooling and rapid turnaround, making it suitable for polymer isothermal crystallization studies. Autorefill feature enables LNCS to be refilled...

Read More »
Metrology Bath provides stability of ±0.005°C at -40°C.
Laboratory Baths

Metrology Bath provides stability of ±0.005°C at -40°C.

Model 7340 covers temperatures from -40 to 150°C, and can be used as standard for calibrating reference-grade thermometers. Unit includes RS-232 interface and Hart's Interface-it software for automating control of bath through PC. Quick drain spout is included so fluids covering different temperature ranges can be easily changed if necessary. Optional floor cart is available for mobility.

Read More »
Solid Surface Sinks come with electronic faucets.
Valves

Solid Surface Sinks come with electronic faucets.

Solid-surface SloanStone sinks can be combined with any Optima® Electronic Faucet to provide practical and aesthetically pleasing lavatories. Sinks withstand heat, stains, and chemical damage; are available in range of colors; and are easy to maintain. Sensor-operated faucets available include models EAF 100 and 150; ETF 610, 600, and 80; and EBF 615, 650, 187, and 85. Applications include...

Read More »
Steam Generator operates on electricity.
Boilers

Steam Generator operates on electricity.

Series ES produces steam up to 90 psig in range from 36-540 PPH. It can be located virtually anywhere, and is compatible with standard feed water. Small in size, almost no heat is lost to surrounding ambient. No flues, fuel lines or tanks are involved in operation. Typical applications include: pipe tracing, steam for tanks, autoclaves and sterilizers, food processing and storage, reactors, and...

Read More »
Cooling System maximizes operation of power transformers.
Spot Coolers

Cooling System maximizes operation of power transformers.

Self-contained Transcool portable auxiliary transformer cooling system has multiple operating modes, featuring programmable, intelligent control with local and remote indications of alarms and system performance. System analysis is provided through historical event, alarm, and warning condition memory storage. Transcool features real-time heat removal calculation, automatic fan and pump...

Read More »
Digital Temperature Switch replaces mechanical thermostats.
Switches

Digital Temperature Switch replaces mechanical thermostats.

Series TS is designed to replace bulb and capillary temperature switches in heating and cooling applications. It includes 3-digit display, 16 A SPDT relay output (3/4 hp), 110 Vac input power, 3 ft temperature sensor, adjustable hysteresis, and defrost cycle programming. With NEMA 4 enclosure and ±1°F accuracy, switch can be utilized in most applications with -58 to +300° F...

Read More »
Cutters and Inserts handle heat resistant alloys.
Inserts

Cutters and Inserts handle heat resistant alloys.

Made with ceramic grade Kyon 2100, cutters work at speeds of 3000 sfm to rough mill nickel, cobalt, and iron based heat resistant alloys. Cutters and inserts also machine Waspalloy, Haynes 25, Inconel 718, Stellite and similar materials at cutting speeds of 2000 to 4500 sfm and feed rates of 0.002 to 0.005 ipt. Also available are KC9110 and KC9125 inserts, both with 3 coating layers: TiCN,...

Read More »

All Topics