Signal Conditioners

Strain Gage Conditioner Module features 1500 Vac isolation.
Signal Conditioners

Strain Gage Conditioner Module features 1500 Vac isolation.

Model 5D70 single input, dual-output, software-programmable conditioner provides input of pressure, force, torque, weight, and other variables. Self-contained in hard aluminum case, it can be used as in-line signal conditioner or reside in host device. Configurable sensitivity ranges from 0.5-16.0 mV/V, full-scale. Unit includes remotely sensed, user-selectable excitation; chopper-stabilized,...

Read More »
Strain-Gage Signal Conditioner suits low-level signals.
Signal Conditioners

Strain-Gage Signal Conditioner suits low-level signals.

Model 163MK accommodates Â-¼, ½, and full wheatstone bridge strain gage applications and includes 2 built-in precision ½ bridge completion resistors. Product offers high-gain differential amplifier, 2-pole Butterworth filter, and built-in excitation supply capable of providing up to 120 mA. Gain can be set up to 5,000, amplifier output is ±10 V, and output filter cutoff...

Read More »
Charge Converters condition piezoelectric sensor signals.
Signal Conditioners

Charge Converters condition piezoelectric sensor signals.

Models 422E35 and 422E36 convert charge-mode signals into low-impedance voltage signals for input to readout, recording, and analysis instruments. In-line units, for use with high-temperature piezoelectric acceleration, pressure, and force sensors, accept source resistances as low as 10 k ohm and temperatures above 400°F. Converters are suitable for harsh environments, such as vibration...

Read More »
Signal Conditioner measures bridge signals.
Signal Conditioners

Signal Conditioner measures bridge signals.

WAVEANALOG Pro Bridge eliminates need for PLC or DCS module by providing bridge excitation voltage and converting millivolt bridge output to standard voltage or current signal, which can be used by control system. With DIP-switch selectable bridge excitation voltages, signal conditioner allows uni- or bi-polar voltage inputs from 0-10 mV to -500/+500 mV, and provides choice of outputs of 0-5 V,...

Read More »
Signal Conditioner provides configurable input/output modes.
Signal Conditioners

Signal Conditioner provides configurable input/output modes.

Universal Signal Conditioner is DIN rail mountable and features galvanic isolation for re-transmission and measurement of isolated analog output signals. It provides 3 measurement samples per second for all input types. Unit also provides 60 V of continuous protection for all inputs and protects outputs and power supplies against over-voltages to 400 W/ms. Three-point insulation is provided up to...

Read More »
Signal Conditioners work with TEDS sensors.
Signal Conditioners

Signal Conditioners work with TEDS sensors.

Multichannel Series 481 prepares measurement signals from piezoelectric sensors for input to recording or analysis instrumentation. Versions are available with read and write capabilities for TEDS (Transducer Electronic Data Sheet) IEEE P1451.4 compliant charge mode and ICP® sensors. Options include RS-232 and RS-485 serial interfaces for daisy-chaining multiple units, and incremental gain...

Read More »
Signal Conditioner provides 3-channel, portable operation.
Signal Conditioners

Signal Conditioner provides 3-channel, portable operation.

Model 480B21 features gain of x1, x10, and x100 for each channel, and frequency response from 0.15 Hz to 50 kHz. Fault indicator alerts of battery condition and potential sensor or input cable problems. Unit includes BNC input and output connectors, 4-pin trixial sensor input connector, external power input, and 12 V auto-lighter, DC power adapter. Model 480B21 operates with triaxial and...

Read More »
Signal Conditioners have buit-in mV/V calibrator.
Signal Conditioners

Signal Conditioners have buit-in mV/V calibrator.

DC Signal Conditioner Models 708, 788, and 728 acquire, condition, display, and classify output of strain gage load cells, pressure transducers, torquemeters, and displacement transducers. Sensitivity is rated from 1 to 4.5 mV/V. Calibration in engineering units is accomplished via keypad or serial port. Built-in calibrators have absolute accuracy of 0.01%. All models provide 2000...

Read More »
Strain Gage Interface Card handles 4- and 6-wire circuits.
Signal Conditioners

Strain Gage Interface Card handles 4- and 6-wire circuits.

AP815, for single strain gages, allows connection of quarter bridges in 4-wire circuit, and half and full bridges in 6-wire circuit. With half bridges, card allows active and compensation strain gages to be arranged separately, and corrects voltage loss at connecting line. Five excitation voltages are available, providing measuring range of 8 to 80 mV/V and 0 V listening mode to assess line...

Read More »
Signal Conditioner accepts strain gauge outputs.
Signal Conditioners

Signal Conditioner accepts strain gauge outputs.

Model 8555 accepts 0 to 50 mV single ended or differential input, making it compatible with most strain gage based load cell or pressure transducer outputs. It has 0 to 5 kHz 7 mA pulse output with 50 psec pulse width, making it compatible with PLC high speed counters. Conditioner contains high impedance instrumentation amplifier and built-in 10 V excitation source for powering one 350-ohm load...

Read More »

All Topics