Signal Conditioners

Signal Conditioner fits limited space applications.
Signal Conditioners

Signal Conditioner fits limited space applications.

DIN rail mount Model 8161A provides conditioned output signals for test, measurement, and process control. Two concurrent outputs offer ability to conduct measurements and control processes, while simultaneously monitoring or recording. Analog voltage and current mode outputs are provided. Built-in shunt calibration resistor with pushbutton actuation simplifies test setup. Unit is suited for...

Read More »
Sensor Signal Conditioner suits 2- to 4-sensor applications.
Signal Conditioners

Sensor Signal Conditioner suits 2- to 4-sensor applications.

Used as programmable link between 1-4 resistive sensors and microcontroller, EM6415 A/D converter calculates conversion parameter and profile coefficients after unit is exposed to calibration signal/profile, then stores them in external EEPROM. Features include high sensor adjust with 14 effective bits, full sensor system on chip, and 4-sensor channel multiplexer. It also offers programmable dual...

Read More »
Signal Conditioner works with piezoelectric sensors.
Signal Conditioners

Signal Conditioner works with piezoelectric sensors.

Model 482C, available in 1, 4, or 8 channel configurations, offers keypad control and utilizes dot matrix display with option for RS-232 computer control setup. Normal power operation is 10-15 Vdc, but, with power adapter, unit can be used with 12 Vdc, 28 Vdc, or 115 Vac/230 Vac power source. Optional features include fixed gain, clamped output for repetitive pulses, integration, filtering, and...

Read More »
Signal Conditioner designed for strain gage-based load cells.
Signal Conditioners

Signal Conditioner designed for strain gage-based load cells.

Model 8159A 1/8 DIN, panel mount signal conditioner provides transducer excitation and signal conditioning with analog output. It includes front panel readout, 2 high and 2 low programmable set points, peak and valley monitoring, front panel calibration, and individual LED function status indicators. Optional features include 4-20 mA output, set point relay contacts for event alarm, shutdown, or...

Read More »
Calibration Conditioner designed for load cells.
Signal Conditioners

Calibration Conditioner designed for load cells.

Microprocessor-based Model SC2000 AM provides 1 or 2 channels and is calibrated against 8.5-digit, traceable digital voltmeter. Conditioner presents test and reference load cell measurements on split-screen display. Its 22-bit processor offers 19 bits of resolution that measures signals from up to 2 load cells. Unit connects to computer running load cell calibration software to generate...

Read More »
Signal Conditioner accepts bridge/strain gauge input.
Signal Conditioners

Signal Conditioner accepts bridge/strain gauge input.

DIN rail mount model WV448 utilizes TouchCAL(TM) technology and provides proportional, selectable DC output. Powered by 9-30 Vdc, unit is field configurable via DIP switches for bridge/strain gauge inputs from ±5 to ±200 mV. Excitation voltage range is 1-10 Vdc @ 120 mA, and outputs can be field-configured for DC signal ranges of 0-10 V, 0-20 mA, or 4-20 mA. All ranges have zero and...

Read More »
Capacitive Signal Conditioners support up to 16 channels.
Signal Conditioners

Capacitive Signal Conditioners support up to 16 channels.

Models 478A16 and 478A17 offer operation of 16 simultaneous channels in one 19 in., rack-mountable chassis. Building block architecture permits addition of features such as gain, filtering, output channel switching, keypad adjustment and control, DC voltage operation, RS-232, and IEEE-488 computer interface. Available in 100-240 Vac power, products support daisy linking of multiple chassis and...

Read More »
Signal Conditioners offer 3 selectable charge sensitivities.
Signal Conditioners

Signal Conditioners offer 3 selectable charge sensitivities.

Series 481 (Option 481-486) Multi-Channel Signal Conditioners allow 1 of 3 charge sensitivities to be selected through single input, using computer or keypad control. Sensitivities include 0.1, 1.0, and 10 mV/pC. Units prepare measurement signals from piezoelectric sensors for input to recording or analysis instrumentation, and are available in 8- or 16-channel configurations. All models install...

Read More »
Signal Conditioner eliminates need for power supply.
Signal Conditioners

Signal Conditioner eliminates need for power supply.

WAVEANALOG 2OLP dual output, loop-powered signal conditioner splits current input signal and isolating control signals while deriving power to operate from output 4-20mA current loop. It uses one 4-20 mA input to produce two 4-20 mA outputs. Product utilizes screw or tension clamp connection technology, and features pluggable connectors for quick installation. Isolation is provided between...

Read More »
Signal Conditioners

Indicator/Conditioner offers auto setup for 25 load cells.

Model 4215 Smart Load Cell Indicator/Conditioner measures and controls strain-gage transducer based systems. It combines force channels, encoder position channels, print capabilities and RS232/485 serial communications. Microprocessor-based unit features ±999,999 display range, 24-bit resolution, and 0.005% nonlinearity. It includes 2-line vacuum fluorescent display, auto load cell...