Gas Detection System suits area gas monitoring applications.
Ultima RF Wireless Network System combines peer-to-peer digital communication with wireless radio signal transmission. Unit features stainless steel housing with independent radio signal capabilities, and allows for up to 40 digital-output gas monitors, 5 network relays, and 5 digital display modules. Each system component operates over 902-928 MHz frequency hopping spread spectrum. Data is...
Read More »pH Sensors exhibit long life at elevated temperatures.
Rosemount Analytical TUpH pH sensors feature SILCORE(TM) technology, a triple-seal contaminant barrier that hinders moisture and material impurities from migrating to pH electrode's metal lead wire. Secondary helical reference pathway hinders reference poisoning, while ACCUGLASS(TM) pH glass formulations minimize glass cracking. Predictive sensor diagnostics alert user to need for calibration,...
Read More »Trace Gas Leak Detector has ultra-high sensitivity.
Portable Qualichek 200 utilizes pressurized trace gas technique and Electron Capture detection system to locate and quantify leaks in various applications. It displays leak rate or concentration. Factory calibrated for SF6, unit has 0-2 V analog output, RS232 serial printer interface, memory for storage of up to 100 results, and built-in fault diagnosis. Unit may be calibrated by user and...
Read More »Kit remotely detects hazardous environmental threats.
Rapid Deployment Kit combines 4 wireless AreaRAE gas detection monitors with in-case charging as well as one Host Controller for monitoring from up to 2 miles away. Through wireless data transmission, incident commander can actively monitor AreaRAE sensors around event perimeter. System prevents needless deployment of personnel into potential hot zones. Housed in military-grade, self-contained...
Read More »Top Purchasing Considerations for Cold Storage Units
On-site cold storage is essential in a number of industries. A new walk-in cooler, walk-in freezer or refrigerated trailer is a major investment and having one that fits your specific needs is crucial.
Read More »Gas Monitor has LCD display.
Pac Ex 2 hand-held, combustible gas and oxygen monitoring device features LCD concentration display with audible, visual, and vibrating alarms. Optional sample pump allows for confined space measurements. Monitor measures combustible gases in 0-100 %LEL range, and range of 0-25% Volume Oxygen. Unit measures for smaller leaks as well as larger concentrations that may exist in oil and gas,...
Read More »Conductivity/Resistivity Sensors offer choice of output.
Series 2850 Sensors provide 2-wire, 4-20 mA output or SÃ-³L digital interface for conductivity/resistivity measurements without local display. Eight 4-20 mA output ranges, plus ability to invert each range, are selectable by user in the field. With SÃ-³L digital interface, conductivity and temperature measurement data are available over single set of wires. Sensors include automatic...
Read More »Monitoring System displays hazardous conditions via Internet.
Sentry WebServer provides graphical display of hazardous gas conditions using Microsoft(TM) web-browser. Safety data is presented visually on any PC, located anywhere in plant or remotely. Product enables users to web-browse to system data from LAN, WAN, or over Internet. Configurable graphic color changes are displayed as events, and all current alarms are displayed and updated on one web page....
Read More »Dissolved-Oxygen Sensor does not consume oxygen.
Equipped with digital, backlit display, HachLDO(TM) measures dissolved oxygen using luminescent measurement technique that does not consume oxygen and requires no electrodes or electrolyte. Measuring technique eliminates frequent calibrations and reduces cleaning frequency.
Read More »Conductivity Sensors have IP68-rated cable connections.
InProÃ-® 7000-VP Sensors have 2 electrodes for low-conductivity ranges and InProÃ-® 7100 Sensors have 4 electrodes for medium- to high-conductivity ranges. All feature watertight VarioPin (VP) cable connection that assures reliable signal transmission even under wetted conditions. Process connections include NPT, 1 Ã-½ and 2 in. Tri-Clamp, and 13.5 and 25 mm fittings. Hygienic designs...
Read More »Gas Monitor uses infrared technology for gas detection.
Microprocessor-based Ultima XIR Gas Monitor has 316 stainless steel enclosure for harsh environments. Gas detector for continuous monitoring of combustible gases and vapors utilizes dual-wavelength heated optics technology, providing compensation for temperature, humidity, and aging effects. Features include field-selectable algorithms, LCD display, 4-20 mA output, and field-programmable relays...
Read More »ISO-Certified Precision Machining and Contract Manufacturing Services from DFF
DFF is an industry leading contract manufacturer specializing in medium to high production precision machined components and electromechanical assemblies. Our 100 CNC machining centers and design-assist capabilities ensure our customers' needs are always met. Check out our video to learn more.
Read More »