Remote Terminal Units (RTU)

Communication Systems & Equipment

Remote Terminal Unit has Ethernet, serial, fiber connectors.

Incorporating 1000BaseT (Gigabit) SFP interface, NetGuardian 216F collects and reports alarms from outdoor enclosures. It supports 16 discrete alarms and 8 analog inputs and offers built-in Web interface for remote monitoring and configuration. Included 7-port Ethernet switch can extend LAN to 7 external devices, and alarm reporting is done via SNMP to multiple masters. Run on -48 V battery...

Read More »

Semaphore Adds 1-Wire Interface to SCADA RTU Product Line
Communication Systems & Equipment

Semaphore Adds 1-Wire Interface to SCADA RTU Product Line

The combination of this Semaphore T-BOX RTU with 1-Wire devices is particularly applicable to infrastructure management and mobile asset management. NASHUA, NH -(September 24, 2008) - Semaphore, a CSE Global company, has introduced a 1-Wire® interface for its T-BOX line of SCADA system products. This interface is compatible with a T-BOX MS Modular System, when equipped with a 32-bit CPU. 1-Wire...

Read More »
Communication Systems & Equipment

RTU and Datalogger delivers real-time information anywhere.

Combining remote terminal unit, datalogger, and telemetry interface, IPm2m® features variety of communication ports, including Ethernet, RS232, RS485, and USB. Each port supports SIXNET and Modbus protocol along with DNP3 slave. Etherbus® PoE supply feature keeps module communicating and powering critical instrumentation during power failure. With means to connect remotely, IPm2m® brings...

Read More »
Communication Systems & Equipment

MODBUS RTU Master also acts as distributed I/O system.

Functioning as MODBUS RTU (RS-485) Master, microNCS® can send up to hundreds of process signals between field or factory floor and control system. One or both MODBUS RTU ports can be configured to poll as many as 32 or 64 other MODBUS RTU slaves, respectively. Product operates as real-time signal gateway by concentrating data from 4 or 8 fully isolated analog inputs and 4 discrete inputs and...

Read More »
Designing and Specifying the Right Loudspeaker System for Emergency Mass Notification in Public Venues
Sponsored

Designing and Specifying the Right Loudspeaker System for Emergency Mass Notification in Public Venues

For every industry, there is nothing more crucial than having effective strategies for dealing with emergency situations. These are events you never hope for, but want the assurance of having the right solutions implemented when time is of the essence. Loudspeaker system optimization is essential when ensuring that communication is not lost when it is most needed. In this guide, you will learn about what key points to keep in mind when designing a loudspeaker system for your campus. This includes performing an on-site sound survey, selecting the right equipment for your applications, complementing your system with the right technology solutions, creating pre-assigned messages for different emergency situations, and having system accessibility no matter the circumstances. Download this guide for additional information on these public safety measures.

Read More »
SCADA RTUs are available with RTD interface.
Communication Systems & Equipment

SCADA RTUs are available with RTD interface.

T-BOX MS Modular System is available with MS-6RTD interface module, which accommodates multiple 2- and 3-wire RTD temperature sensors. Along with process control, T-BOX performs alarm management and data logging. Included push technology - IP forwarding, e-mail with attached files, SMS text - keeps multiple recipients fully informed of status for all assets. Via integral web server, this IP-based...

Read More »
Communication Systems & Equipment

TBOS Mediation Device provides network alarm monitoring.

After taking TBOS alarm data from equipment, NetMediator T2S G5 converts data to detailed SNMPv3 traps. System can then send alarms to master or send instant pager and email notifications directly to techs in field. Compatible with all standard TBOS gear using RS-485 polling ports, LAN-based SNMP/DCPx RTU monitors up to 4,096 TBOS alarms, as well as 32 or 64 discrete alarm points. With SNMPv3...

Read More »
RTU System uses driver to communicate with wireless sensors.
Communication Systems & Equipment

RTU System uses driver to communicate with wireless sensors.

Featuring added driver, IP-based T-BOX RTU enables integration of SCADA, control, and communications functionality in one package. Driver allows RTU to communicate with network of Coronis Systems wireless sensors and brings benefits of T-BOX technology to SCADA system applications. RTU can serve information including alarms, live status, machine health, trends, and historical reports to multiple...

Read More »
Communication Systems & Equipment

ISaGRAF 5 Embedded in Semaphore's New Compact SCADA System RTU

Montreal, Canada - December 20, 2007 - ICS Triplex ISaGRAF Inc., the leading automation software technology partner, announced today that its flagship product ISaGRAF is the software of choice for Semaphore's new Kingfisher G30 compact remote terminal units. The Kingfisher G30 fully embeds the ISaGRAF 5 control software environment to provide support both the IEC 61131-3 and IEC 61499 standards....

Read More »
Communication Systems & Equipment

SNMPv3 Support in the New NetGuardian 832A G5 Provides Enhanced Security

FRESNO, Calif., Dec. 20, 2007 -- DPS Telecom, a leading developer of network alarm monitoring solutions, recently announced that its NetGuardian 832A G5 RTU now includes advanced support for SNMPv3. The NetGuardian G5 can report alarms in SNMP v1, v2c, or v3. This allows you to report alarms effectively, no matter what SNMP version you are using. You have the ability to choose which SNMP versions...

Read More »
Communication Systems & Equipment

Remote Terminal Unit features open programming.

Suited for SCADA system applications, Kingfisher G30 features 32-bit ARM9 main processor, 32 MBytes SDRAM, and 16 Mbytes Flash for high-speed data logging over extended periods. By employing ARM 7 processor on intelligent I/O module, RTU can process inputs and outputs on 1 ms interval with full sequence-of-events monitoring. Integral communications include 10/100 BaseT Ethernet, USB 2.0, and...

Read More »

All Topics