RM9-THz Radiometer comes with digitally synthetized lock-in amplifier.
Designed with NIST-calibrated pyroelectric sensor, THz absorber and 18 Hz chopper, RM9-THz Radiometer is used for measuring power levels of 50nW to 100mW in 0.7 to 10 THz wavelength range. Featuring 8mm aperture, noise levels of ~20nW over 10s and response times of 3.5s with display, unit can be connected to any Ophir meter, PC interface, Nova II, Vega smart displays or Juno PC interface.
Read More »RM9-THz Radiometer comes with digitally synthetized lock-in amplifier.
Designed with NIST-calibrated pyroelectric sensor, THz absorber and 18 Hz chopper, RM9-THz Radiometer is used for measuring power levels of 50nW to 100mW in 0.7 to 10 THz wavelength range. Featuring 8mm aperture, noise levels of ~20nW over 10s and response times of 3.5s with display, unit can be connected to any Ophir meter, PC interface, Nova II, Vega smart displays or Juno PC interface.
Read More »SR-6500 NIR Spectroradiometer covers UV/VIS/NIR range of 350-2500 nm.
Including wireless Bluetooth and USB communications, SR-6500 NIR Spectroradiometer offers operating range of 0-40°C. Measuring 12.4 x 8.7 x 4.4 inches (31.5 x 22.9 x 38.7 cm), unit weighs 11 pounds (4.99 kg). Calibrated to NIST-traceable radiometric calibration standards, device enables 1.5nm, 3.0nm and 3.8nm resolutions @ 700nm, 1500nm and 2100nm respectively. Providing auto dark current...
Read More »SR-6500 NIR Spectroradiometer covers UV/VIS/NIR range of 350-2500 nm.
Including wireless Bluetooth and USB communications, SR-6500 NIR Spectroradiometer offers operating range of 0-40°C. Measuring 12.4 x 8.7 x 4.4 inches (31.5 x 22.9 x 38.7 cm), unit weighs 11 pounds (4.99 kg). Calibrated to NIST-traceable radiometric calibration standards, device enables 1.5nm, 3.0nm and 3.8nm resolutions @ 700nm, 1500nm and 2100nm respectively. Providing auto dark current...
Read More »Custom Knob Solutions - Maximum Grip and Comfort
To learn more about the different types of knobs available or which ones to select for your specific application, download this product guide.
Read More »UV LED Radiometer with Probe suits high-intensity UV processes.
Able to maintain stability in high-temperature and intense UV flood and spot curing environments., X1-1-RCH-116-4 UV & Blue Light LED Curing Radiometer features horizontally constructed photodetector assembly. Remote controllable, 4-channel unit also features auto-ranging from 0.1 pA to 200 -µA or manual range selection and selectable integration time from 20 msec to 1 sec. RCH-116-4 wand-style...
Read More »UV LED Radiometer with Probe suits high-intensity UV processes.
Able to maintain stability in high-temperature and intense UV flood and spot curing environments., X1-1-RCH-116-4 UV & Blue Light LED Curing Radiometer features horizontally constructed photodetector assembly. Remote controllable, 4-channel unit also features auto-ranging from 0.1 pA to 200 -µA or manual range selection and selectable integration time from 20 msec to 1 sec. RCH-116-4 wand-style...
Read More »UV/White Light Meter features wireless data transfer.
Used for measurement of UV-A irradiation and visible illumination, Apollo 1.0 NIST-traceable Radiometer/Photometer uses Bluetooth-® for sensor measurements and data transmission. Band pass filter stack, containing only non-fluorescent filters, optimizes measurement accuracy of visible light emission from UV-A lamp, while auto ranging and concurrent measuring of visible light and UV-A...
Read More »UV/White Light Meter features wireless data transfer.
Used for measurement of UV-A irradiation and visible illumination, Apollo 1.0 NIST-traceable Radiometer/Photometer uses BluetoothÃ-® for sensor measurements and data transmission. Band pass filter stack, containing only non-fluorescent filters, optimizesÃÂ measurement accuracy of visible light emission fromÃÂ UV-A lamp, while auto ranging and concurrent measuring of visible light...
Read More »Spectroradiometer enables inspection to Rec. 2020 standards.
With contrast ratio of 1,000,000:1 and wavelength resolution of 0.4 nm, GS-1290 Display Measurement System is useful for metrology tasks in display fabrication, including inspection of reference monitors. High blue light sensitivity makes system effective for use with virtually all display types, including LED backlit displays. Equipped with AVS telescope for image acquisition, GS-1290 DMS has...
Read More »Spectroradiometer enables inspection to Rec. 2020 standards.
With contrast ratio of 1,000,000:1 and wavelength resolution of 0.4 nm, GS-1290 Display Measurement System is useful for metrology tasks in display fabrication, including inspection of reference monitors. High blue light sensitivity makes system effective for use with virtually all display types, including LED backlit displays. Equipped with AVS telescope for image acquisition, GS-1290 DMS has...
Read More »SRG Global Coatings Enhance Surface Durability, Efficiency, Design Flexibility
SRG Global's automotive coatings enhance the structural integrity of the finished part while also improving vehicle efficiency. Check out our video to learn more.
Read More »