Radiation Sensors / Detectors

Flame Ionization Device detects VOCs, including methane.
Radiation Sensors / Detectors

Flame Ionization Device detects VOCs, including methane.

Weighing 8.1 lb, MicroFID(TM) incorporates tutor key that guides end-user through basic operation. Critical data is displayed and logged in less than 3 sec within 0.5-50,000 ppm concentration range via built-in datalogger, and 2-step calibration holds for entire workday. Immune to possible interferences such as water vapor, self-contained, hand-held unit is intrinsically safe and features...

Read More »
Radiation Sensors / Detectors

Wireless Sensor detects radiation and hazardous gases.

AreaRAE-Gamma is equipped with RF modem that enables communication of real-time data transmission of VOC, toxic chemical, and radiation data. It transmits on license-free ISM band and has 2 mi communication range. Unit integrates PID, LEL, electrochemical, and radiation monitoring needed for accurate situation assessment. Features include up to 4 gas sensors, built-in pump, interchangeable Li-ion...

Read More »
Charged-Plate Monitor automates data collection.
Radiation Sensors / Detectors

Charged-Plate Monitor automates data collection.

Model 157 combines precision charge measurement capability with one USB serial interface to allow user to control unit from computer. With TREK software, operators can program test sequences and download test results, allowing quantitative tests to be repeated, analyzed, programmed, saved, and retrieved. Unit provides virtually infinite impedance loading of ion collecting plate, while allowing...

Read More »
Pulsed Discharge Detector offers plug-and-play operation.
Radiation Sensors / Detectors

Pulsed Discharge Detector offers plug-and-play operation.

Model D3-1-HP helium ionization detector, with Valco Helium Purifier, is specified for HP 6890 gas chromatograph. It includes helium purifier and is suitable for use with columns from 50 micron capillaries to 1/8 in. packed. Universal detector is non-radioactive and non-destructive. With no open flame, no hydrogen requirement and close-to-true-mass response, unit can upgrade FIDs in petrochemical...

Read More »
Detector provides circumvention against nuclear blast.
Radiation Sensors / Detectors

Detector provides circumvention against nuclear blast.

Nuclear Event Detector (NED) senses ionizing radiation pulses with very low detection levels that are adjustable, then generates signal that is transmitted to processor or logic device. Device then controls hardware that may be susceptible to radiation exposure, thereby preventing upset and/or permanent damage. NED differentiates between actual nuclear event and power up, preventing false...

Read More »
Helium Ionization Detector provides on-site analysis.
Radiation Sensors / Detectors

Helium Ionization Detector provides on-site analysis.

D3-1-HP Pulsed Discharge Helium Ionization Detector is non-radioactive, non-destructive, highly sensitive, and universal. Response is linear over wide range, and MDQs for most compounds are in low ppb range. With no open flame, no hydrogen requirement, and close-to-true-mass response, D3-1-HP is suitable for FIDs in petrochemical environments. When helium discharge gas is doped with suitable...

Read More »
Radiation Sensors / Detectors

Instrument provides surveillance of gamma radiation.

GammaTRACER combines GM based survey instrument and microprocessor-controlled data logger in an environmentally sealed package for unmanned monitoring. It is capable of recording up to 12,800 measurements based on user-selectable time periods ranging from 1 min to 2 hr. GammaTRACER measures dose rates from .0l mSv/hr to l0,000 mSv/hr. Data can be downloaded directly into a computer via 1182 IR...

Read More »

All Topics