Other Process Heaters

Programmable Hot Plate features milled-flat aluminum top.
HVAC

Programmable Hot Plate features milled-flat aluminum top.

Suited for heating silicon wafers, electronic chips, displays, and adhesives, EchoTherm(TM) HP40A is programmed via front panel membrane switch and custom LCD. Digital unit can store 10 programs in memory of as many as 10 steps each, where each step includes temperature, temperature ramp rate, and time. Measuring 8 x 8 in., cast aluminum heater plates can be evenly heated from ambient to 400°C...

Read More »
Hot Plates and Stirring Hot Plates handle large samples.
HVAC

Hot Plates and Stirring Hot Plates handle large samples.

Available in 100, 115, and 230 Vac, 50/60 Hz versions, EchoTherm(TM) HP61 and HS61 feature 10 program memory with 10 steps per program, temperature ramping, RS232 I/O port, membrane keyboard, and full-function LCD where all parameters are continuously visible. Heater tops, offered in ceramic or milled-flat cast aluminum, are 12 x 12 in. with 1,400 W heaters. Temperatures can be set to 450°C on...

Read More »
Digital Stirring Hot Plate provides 5 stirring positions.
HVAC

Digital Stirring Hot Plate provides 5 stirring positions.

Suited for laboratories where reproducible, hands-off sample preparation and experimentation are required, EchoTherm(TM) Model HS65 features 12 x 12 in. solid ceramic glass heater plates that can be heated from ambient to 400°C. Stirring speed is 100-1,500 rpm and controlled by optical coupler to 10 rpm. With Model HS65, programming is done through front panel membrane switch and full-function...

Read More »
HVAC

Hot Plates and Stirrers offer up to 9 positions.

Featuring 12 in. square ceramic heater tops, Analog Stirring Hot Plates have temperature range up to 450°C. Five-position stirring unit can stir 5-800 ml beakers, while 9-position unit can stir 9-500 ml beakers of aqueous solutions with stirring range from 100-1,500 rpm. Available in 100 Vac/50 Hz, 115 Vac/60 Hz, 220 Vac/60 Hz, and 230 Vac/50 Hz, hot plates support more than 50 lb on plate...

Read More »
Managing the New FGD Wastewater Regulations
Sponsored

Managing the New FGD Wastewater Regulations

EPA Steam Electric Power Generating Effluent Limitations Guidelines, or ELG’s, impact coal-fired power plant operations and their wastewater management. Specifically, the ELG’s impose limits for suspended solids, arsenic, mercury, selenium, and nitrate/nitrite for Flue Gas Desulfurization (FGD) wastewater. These regulations drive the need for technology based solutions that address and adapt to variables such as the nature of wastewater streams, types of contaminants, contaminant loading, and costs. In this guide you will learn about the best available technologies for complying with the new standards. One of the leading contenders in this process is the Fluidized Bed Reactor or FBR, which removes soluble selenium and other metals from FGD wastewater. Advantages of fluidized bed reactors include optimum microorganism efficiency, smaller overall footprint, steady-state operation, lower hydraulic residence times, system robustness, and lower costs. Download this guide for additional information on FBR technology for treating FGD wastewater, including pilot studies and tests, and polishing selenium removal options.

Read More »
Compact HPLC Column Heater is UL, CSA, and CE compliant.
HVAC

Compact HPLC Column Heater is UL, CSA, and CE compliant.

Operating from 12 Vdc, EchoTherm(TM) model CO20 offers range from room temperature to 90°C, regulated to ±0.1°C via PID temperature control software. It holds columns up to 30 cm long by ¼ or 3/8 in. dia in mounting clips and provides digital display of target and actual chamber temperatures. Features include injection counter, 30 day timer with alarm, and user settable auto-off. Unit comes...

Read More »
HVAC

Capillary Gas Chromatograph offers trace level analysis.

Utilizing FID, FPD, ECD, FTD and TCD detectors, GC-2010 Plus ensures data quality for range of applications. Unit features Advanced Flow Technology, which consists of digital pressure controllers, software, and backflush kit or detector splitting system. FPD detector features double focusing optics, while FID ensures sensitivity with minimum detected quantity of 1.5 pgC/s. Featuring optimized...

Read More »
Hot Plate offers individual stirring control for 5 vessels.
HVAC

Hot Plate offers individual stirring control for 5 vessels.

Featuring 12 in. square ceramic heater top with temperature range to 450°C, Model HS15 can heat and stir five 800 mL beakers at stirring range of 100-1,500 rpm. Unit measures 12.5 x 19 x 5.25 in. and can support over 50 lb on plate surface. Chassis design keeps spills out of interior of unit, and all controls are mounted well in front of heater surface to protect against accidental burns....

Read More »

Reverse Cycle Chiller is Alternative to Geo-Thermal
HVAC

Reverse Cycle Chiller is Alternative to Geo-Thermal

MAIN STORY Another advocate of the small chiller sector was John Seppamaki of Aqua Products who noted the use of several small chillers together for larger loads which give you staging and backup." Among the smaller size approaches, he cited, were 1.5- to 5-ton chillers built using micro-channel technology and a reverse cycle chiller that can produce hot water forced air or radiant floor heating...

Read More »
HVAC

Hot Plates and Stirrers handle 2 liter samples or less.

Offering stirring speeds from 100-1,500 rpm, EchoTherm(TM) HP50 and HS50 Digital Hot Plates and Digital Stirring Hot Plates feature membrane keyboard and full function LCD, where target and actual sample or plate temperature, stirring speed, and timer are continuously visible. Heater tops are 6 x 6 in. square and feature 400 W heaters. They are available in milled-flat cast aluminum or ceramic...

Read More »

Jasco's Featured Product at Pittcon 2009
Health, Medical, & Dental Supplies and Equipment

Jasco's Featured Product at Pittcon 2009

Preparative SFC System with Chiral Detection JASCO's featured product at Pittcon 2009 will be the Preparative SFC system with chiral detection. Providing a versatile modular design and excellent performance, this system is the ideal solution for fast, reliable chiral separation and isolation. The heart of the system is JASCO'S patented back- pressure regulator, which allows control of system...

Read More »
Aqua Dam Water Filled Flood Barrier
Sponsored

Aqua Dam Water Filled Flood Barrier

Aqua Dam is the ultimate solution for large-scale water control projects. It combines lightweight, large size, and portability all in one innovative product. To learn more about the uses, and applications of Aqua Dam, or to see it in action, check out our new video to get all the details.

Read More »

All Topics