I/O Module offers 24 independently programmable pins.
USBI/O24 is designed for input and output of digital signals from computer by connection to USB port. Based on FTDI FT8U245AM USB IC and UBICOM SX48 microcontroller, module is capable of transfer rates up to 250,000 x 8 bit port reads or writes per second. Input pins are TTL level compatible and output pin can sink or source up to 30 mA per pin. With integrated Type-B USB connector onboard, unit...
Read More »
I/O Module offers 24 independently programmable pins.
USBI/O24 is designed for input and output of digital signals from computer by connection to USB port. Based on FTDI FT8U245AM USB IC and UBICOM SX48 microcontroller, module is capable of transfer rates up to 250,000 x 8 bit port reads or writes per second. Input pins are TTL level compatible and output pin can sink or source up to 30 mA per pin. With integrated Type-B USB connector onboard, unit...
Read More »Weighing System exchanges information on network.
ISP Momentum Weighing Module provides direct, load-cell interface. Module can be used with Modbus Plus, Modbus TCP/IP, Profibus, or with any M1 CPU processors. It can be used as distributed I/O module to stand-alone control system without use of PLC processors. Digitizer interfaces with up to 8 load cells to give one weighing measure. It has 4 inputs (tare, reset tare, zero, print) and 2...
Read More »Weighing System exchanges information on network.
ISP Momentum Weighing Module provides direct, load-cell interface. Module can be used with Modbus Plus, Modbus TCP/IP, Profibus, or with any M1 CPU processors. It can be used as distributed I/O module to stand-alone control system without use of PLC processors. Digitizer interfaces with up to 8 load cells to give one weighing measure. It has 4 inputs (tare, reset tare, zero, print) and 2...
Read More »
Epoxy Crusher Backing Solutions for Construction Aggregate & Ore Mining Applications
This white paper provides a guide to epoxy crusher backing solutions for construction aggregates and ore mining applications.
Read More »Control Modules ease equipment retrofits and rebuilds.
56AMXN module allows applications running on Allen-Bradley ControlLogix(TM) controller to communicate with Reliance Electric AutoMax(TM) control system or AutoMax networks. 1756 single-slot drive module allows users to keep existing Reliance Electric DPS drives in place when updating to ControlLogix-based solution. Multibus ControlNet (MBCN) module allows application running on AutoMax controller...
Read More »Control Modules ease equipment retrofits and rebuilds.
56AMXN module allows applications running on Allen-Bradley ControlLogix(TM) controller to communicate with Reliance Electric AutoMax(TM) control system or AutoMax networks. 1756 single-slot drive module allows users to keep existing Reliance Electric DPS drives in place when updating to ControlLogix-based solution. Multibus ControlNet (MBCN) module allows application running on AutoMax controller...
Read More »
Analog Output Modules deliver fast waveform output for PCI.
PCI-6731 and PCI-6733 have 4 and 8 analog output channels, respectively, and deliver 1 MS/sec per channel, 16-bit, analog waveform outputs. Both have 2 counter/timers, software-controlled onboard timing signal routing, and connect to company's instrumentation, data acquisition, motion, and vision products. DAQT(R) 6.9 driver software interfaces to LabVIEW(TM), LabWindows(TM)/CVI, and Microsoft...
Read More »
Analog Output Modules deliver fast waveform output for PCI.
PCI-6731 and PCI-6733 have 4 and 8 analog output channels, respectively, and deliver 1 MS/sec per channel, 16-bit, analog waveform outputs. Both have 2 counter/timers, software-controlled onboard timing signal routing, and connect to company's instrumentation, data acquisition, motion, and vision products. DAQT(R) 6.9 driver software interfaces to LabVIEW(TM), LabWindows(TM)/CVI, and Microsoft...
Read More »Modules and Controller connect I/O to Ethernet Powerlink.
System 2003 modules can be integrated in Powerlink network. With Ethernet Powerlink, cycle times of 400 microseconds with maximum network jitter of less than 1 microsecond are possible. By using EX481 bus controller and 2003 modules, physically synchronized output behavior can be achieved on multiple I/O stations on network. Ethernet connection is made via RJ45 connector.
Read More »I/O Cards provide zone control.
1799-ZCIOV (sinking output) and 1799-ZCIOB (sourcing output) modules include Zone Interlocking Protocol, a parameter-based technology that allows 1 card to consume data directly from up to 4 other ZCIO cards, providing response time of 2 msec. ZCIO cards are designed for applications where machine provides enclosure for I/O or where I/O board fits into field replaceable unit. DeviceNet(TM) is...
Read More »
TPA Motion Introduces Industry's First Compact Robotic Positioner for Medical Devices
TPA Motion's microplate handling robots are designed specifically for medical instruments and lab automation devices. Check out the video to learn more.
Read More »