Optical Biosensors detect pH, CO2, and O2.

Optical Biosensors detect pH, CO2, and O2.

Fluorescence-based Optical Biosensors measure typical blood gas parameters in tissue engineering, organ perfusion, and general physiology applications. Units are inherently self-referencing, eliminating potential for measurement error arising from changes in sample properties over duration of experiment. Shipped pre-calibrated, USP Class VI-certified sensors are completely sterilizable and...

Read More »
Fully Integrated Protocol Viewer automates PCIe® 3.0 testing.

Fully Integrated Protocol Viewer automates PCIe® 3.0 testing.

Intended for use with Infiniium 90000 Series oscilloscopes, Agilent N8816A PCIe 3.0 protocol viewer software helps engineers identify protocol errors and simultaneously analyze analog waveform characteristics. It provides time-correlated views of physical and transaction layer errors, performs 128/130 bit decoding on PCIe 3.0 traffic, and displays serial packet data synchronized with analog view...

Read More »
Ductless Balance Enclosures come in 24 in. wide model.

Ductless Balance Enclosures come in 24 in. wide model.

In addition to 32 and 48 in. wide models, PowderSafe(TM) Type A Enclosures come in 24 in. AC705 model suited for applications with restricted lab bench space. Each enclosure comes with HEPA filtration to contain particulate while protecting operator from exposure. Mini-helic air flow gauge and HEPA filter change indicator light are also standard on Model AC705. Leak-tested prior to shipment,...

Read More »

Preclinical Imaging System supports in vivo animal imaging.

Integrating optical imaging and low dose microCT, IVIS Spectrum CT enables simultaneous molecular and anatomical longitudinal studies. System provides insights into complex biological systems in small animal models used to develop clinically translatable discoveries. Features include optical sensitivity capable of achieving detection of a few cells and 3D reconstructions of optical molecular...

Read More »
5 Questions to Ask When Choosing a Custom Glass Manufacturer
Sponsored

5 Questions to Ask When Choosing a Custom Glass Manufacturer

Due to the inherent complexity of glass fabrication, many professionals seeking glass services know exactly what kind of part is needed, but are unclear on the intricacies of the actual manufacturing process. PEG's exclusive guide is designed to help professionals navigate the custom glass manufacturing process with valuable information.

Read More »
Industrial Enclosures feature polycarbonate construction.

Industrial Enclosures feature polycarbonate construction.

Available in 7 sizes from 6 x 6 x 4 in. to 18 x 16 x 10 in., Non-Metallic Industrial Enclosures come with clear or solid doors and are certified to UL 50, Type 3R, 4, 4X, and 12. Units feature flat panel hinged lid, external latches, and integrated lock hasp as well as flush-fit swing panel and DIN rail mounting system.

Read More »
Heavy-Duty Slides are offered with carriage bolt holes.

Heavy-Duty Slides are offered with carriage bolt holes.

Designed to accommodate applications such as utility and emergency vehicle storage, toolboxes, and industrial equipment trays and drawers, RoHS-compliant models 9301, 9307, and 9308 are offered with carriage bolt holes that provide for single-tool installation. This facilitates mounting while also reducing labor time. Located adjacent to existing mounting holes, square carriage bolt holes...

Read More »

Audio Analyzer offers digital audio interface options.

Supporting AES3, SPDIF, and DSI formats, Model U8903A enables engineers to analyze and verify wide range of digital audio applications. Analyzer contains full functions of analog domain and digital domain audio measurement in single unit, allowing complex cross-domain measurements in wireless communications and consumer audio industries. Featuring user-selectable logic level input of 1.2-3.3 V,...

Read More »
Residential Combustion Analyzer comes in 2 or 3 gas options.

Residential Combustion Analyzer comes in 2 or 3 gas options.

Suitable for 90%+ efficiency systems, Model BTU900 meets needs for boiler and burner set-ups, servicing, and maintenance. Unit measures O2, CO, and CO2, and is upgradeable to NO/NOx. Designed with unbreakable metal connections, analyzer features field-replaceable sensors, as well as built-in manometer, thermometer, and CO leak detector. Powered by rechargeable battery, Model BTU900 includes...

Read More »

Carbon Isotopic Analyzer delivers precision and stability.

With 0.1 per mil precision for 13C/12C ratio measurements in CO2 in 5 min measurement and 0.5 per mil or less drift over 24 hr, G2131-i Isotopic Carbon Analyzer helps scientific applications resolve CO2 dynamics in atmosphere, plant respiration, and ocean. It measures carbon isotopic ratios and lets users redirect experiment mid-stream to pursue most interesting/valuable results. Able to be...

Read More »
Particle Sizing Instruments use diffusion barrier method.

Particle Sizing Instruments use diffusion barrier method.

Zetasizer products eliminate protein denaturation when measuring zeta potential using electrophoretic light scattering (ELS). Utilization of U-shaped disposable capillary cell promotes accuracy and repeatability of zeta potential results for proteins. Diffusion barrier method protects protein by keeping it away from electrodes within pool of buffer, preventing aggregation thereby ensuring...

Read More »

All Topics