Gas / Chemical Monitors

Multi-Gas Monitor is suited for mining applications.
Gas / Chemical Monitors

Multi-Gas Monitor is suited for mining applications.

Weighing 8.6 oz, ergonomic M40M alerts users to hazardous levels of oxygen, methane, carbon monoxide, and hydrogen sulfide through visual, audible, and vibratory alarms. LCD displays continuous, real-time gas readings and has amber backlight for low-light visibility. Features include 4-button interface, continuous loop datalogger, and peak/hold functions. Impact-resistant case has IP65 rating and...

Read More »
Transmitter/Controller accepts up to 3 chlorine probes.
Gas / Chemical Monitors

Transmitter/Controller accepts up to 3 chlorine probes.

MicroChem(TM)2, available with reagentless, free, and total chlorine probes, features multiple measurement capability and single or dual PID control outputs. Enabling continuous online measurement and control of chlorine dosage, CL4000 probes are designed for bufferless operation and have no moving parts. Multi-parameter, multi-channel system is capable of receiving inputs from up to 3 sensors...

Read More »
Handheld Meter measures chlorine over 0-200 mg/L range.
Gas / Chemical Monitors

Handheld Meter measures chlorine over 0-200 mg/L range.

Chlorometer Duo measures all water distribution system chlorine levels. Calibrated to monitor residual chlorine using DPD standard method, unit reveals free and total chlorine in 0-5 mg/L range with resolution of 0.01 mg/L. Higher range test uses iodine release technique for total chlorine analysis with 1 mg/liter resolution. Each test takes 1 min, and results are displayed on 10 mm high LCD...

Read More »
Gas / Chemical Monitors

Personal Gas Monitor is suited for tough environments.

Weighing from 3.7-4.6 oz depending on sensor type, Gasman alerts user to presence of hazardous gas by vibrating and giving 95 dBA alarm with red/blue alarm light. Instrument offers impact resistance and ingress protection to IP 65/67. Features include single-button control and interchangeable i-module intelligent sensors for oxygen, toxic, and flammable gas monitoring. Backlit LCD display lets...

Read More »
Emissions Monitoring System offers 2-point stream switching.
Gas / Chemical Monitors

Emissions Monitoring System offers 2-point stream switching.

MicroCEM(TM) TS field-mountable, continuous emissions monitoring system allows facilities to monitor 2 sample points/stacks with one analyzer system. Monitor extracts sample gas, conditions sample, analyzes sample for desired components, and processes emissions data by utilizing calibration validation calculations/procedures and oxygen diluent corrections. MicroCEM TS stores relevant raw/diluent...

Read More »
Monitoring Systems detect 400 and 500 series refrigerants.
Gas / Chemical Monitors

Monitoring Systems detect 400 and 500 series refrigerants.

Utilizing photoacoustic IR sensing technology, Chillgard L Series Monitors comply with ANSI/ASHRAE 15-1994 requirements for refrigeration monitoring. Offered in single-point diffusion and 4-point pumped models, Chillgard LS Monitors have water-resistant plastic enclosure and can detect R11, R12, R22, R123 and R134A refrigerants, as well as 400 and 500 series. Chillgard LC Control Module works...

Read More »
Window Tint Meter ensures proper visibility.
Gas / Chemical Monitors

Window Tint Meter ensures proper visibility.

Pocket Detective 3.0 measures both Visible Light Transmission and Visible Light Reflectance. Operating from 1,600 mAh internal battery, unit includes Magna-Alignment(TM) auto alignment system, pushbutton operation, LCD digital readout, panel-light function indicators, and auto shut-off. Instrument measures all windows of vehicle, including roll-down and fixed glass. It is also suited for...

Read More »
Gas Monitors come in duct-mount versions.
Gas / Chemical Monitors

Gas Monitors come in duct-mount versions.

Ultima X Gas Monitors, with duct-mount kit, enable gas sampling even when flow rate is at high velocity. Using catalytic, electrochemical, and infrared technologies, they provide continuous monitoring of combustible and toxic gases and oxygen deficiency. Units include interchangeable smart sensors, onboard LEDs, and display that alternates between sensor reading and gas type. Sensors can be...

Read More »
Toxic Gas Monitor utilizes power of Pocket PC computers.
Gas / Chemical Monitors

Toxic Gas Monitor utilizes power of Pocket PC computers.

Monitor enables users to mix or match up to 5 gas sensors, plus temperature, while WolfSense(TM) application software allows for clear, real-time display of measurements and instantaneous data-logging and long-term trending. In addition to user-attached text, graphic, and audio notes, logged files include measurement data and calibration info. Desktop PC software is included for analysis and...

Read More »
Gas Sampling System is probe mounted.
Gas / Chemical Monitors

Gas Sampling System is probe mounted.

Designed to prepare wet, hot, and dirty stack gases for analysis, 1640 Mini-GASS (Gas Analysis Sampling System) allows users to accurately monitor smoke stack emissions. Gas conditioning system extracts sample gas via integrated sample probe and passes it through series of filters, scrubbers, and dryers. Housed in stainless steel cabinet, components remove water, acid mist, and ash without...

Read More »

All Topics