Electrodes

Electrodes

pH Electrodes offer drift-free reference system.

Orion ROSS Ultra screw-cap electrodes are available in standard glass-bulb, flat-surface, semi-micro, and epoxy-bodied styles to best determine pH of variety of sample types. Screw-capped electrodes accommodate applications such as titrations. ROSS Ultra half-cell reference electrode is available for applications where separate sensor and reference electrodes are preferred.

Read More »
pH Electrodes utilize drift-free reference system.
Electrodes

pH Electrodes utilize drift-free reference system.

Available in rugged and standard glass bulb, flat-surface, semi-micro, and epoxy-bodied styles, ROSS Ultra(TM) pH electrodes use virtually drift-free reference system that is unaffected by temperature or composition. ROSS Ultra half-cell reference electrodes are also available for applications where separate sensor and reference electrodes are preferred.

Read More »
Electrodes withstand slurry applications.
Electrodes

Electrodes withstand slurry applications.

Abrasion- and corrosion-resistant 160-E electrodes consist of tungsten-carbide particles in nickel-silicon-boron matrix. Resistant to fine particle erosion, products are available in 3/16 in. diameter, and may be used with equipment operating at 130-155 A. Suitable applications include dredge rotary cutter heads, pipe ID and filtering screens, and drill bits and stabilizers.

Read More »
Electrodes

pH/Temperature Electrode suits industrial wastewater use.

With application field including suspensions, solvents, acids, and alkalis, InPro® 4250 electrode offers 0-14 pH range and integral temperature sensor. Its XEROLYT®PLUS reference system consists of solid polymer, which does not require refilling of electrolyte. Pressure resistant for operation pressures up to 232 psig, XEROLYT®PLUS is in direct contact with measuring media using...

Read More »
Electrodes

Temperature/pH Electrode suits harsh chemical processes.

InPro 4800, with gel electrolyte, provides resistance towards oxidizing media, solvents, and acid or alkali solutions, with operating pressures to 188 psi at 266°F. Offerings include pressure-compensated reference system, diffusion path in 2 separated, reference electrolyte chambers, and dirt-repellant, annular PTFE reference junction. Unit also includes integral temperature sensor and...

Read More »
Electrodes

Electrode Assemblies/Separators are designed for EDLCs.

EXCELLERATOR® electrode assemblies and separators for Electrochemical Double Layer Capacitors (EDLCs) provide strength and dimensional stability and allow for high carbon loading. Bound directly to current collector, electrodes are available in various thicknesses, densities, and shapes in single- or double-sided electrode assemblies. EXCELLERATOR® Separators are chemically resistant...

Read More »
Ceramic Electrode Assemblies spark to ignite gas.
Electrodes

Ceramic Electrode Assemblies spark to ignite gas.

Custom configured for direct spark and hot-surface gas ignition, Electrode Assemblies incorporate flame-sensor rods and spark-ignition systems in variety of sizes. Custom fabricated to position spark gap precisely, they can use Steatite or alumina ceramics for applications up to 1,800°F. Rods can be made from Kathal D, Kathal Al, stainless steel, and other specialty metals. Brackets are...

Read More »
Oxygen Electrodes last longer in plasma cutting.
Plasma / Flame / Laser Cutters and Cutting Machinery

Oxygen Electrodes last longer in plasma cutting.

SilverPlus(TM) 200-amp silver/hafnium electrodes last up to 3 times longer than company's previous products. They fit company's Hypertherm HT2000, HT2000LHF LongLife, and MAX200 plasma cutting systems. Electrode has silver front end fused onto copper base. Hafnium emitter interfaces with silver, creating better adhesion and cooling than traditional copper interfaces. Hafnium erodes to...

Read More »
Membranes

MEAs are suitable for stationary PEM fuel cells.

PRIMEA(R) Series 56 MEAs (membrane electrode assemblies) is composed of ion exchange membranes and 2 electrodes that convert fuel into electricity. Arranged in stacks of 10s to 100s within 1 fuel cell, MEAs integrate ePTFE (expanded polytetrafluoroethylene) membrane into electrochemical applications. They are offered with optional gas diffusion media. MEAs are also available for transportation...

Read More »

All Topics