I/O Bus Controller features Ethernet cabling.
Controls and Controllers

I/O Bus Controller features Ethernet cabling.

EX484 consists of EX481 with integrated 4X hub. Tree or star network topologies can be implemented in accordance with Fast Ethernet standard on which ETHERNET Powerlink is based. Cabling between individual Powerlink stations occurs using Cat 5 cables, which allows maximum distance of 100 m between 2 nodes. EX484 supports all standard I/O modules for System 2003.

Read More »
DC Drive offers 1% speed regulation.
Motor Controllers and Drives

DC Drive offers 1% speed regulation.

M1 DC drive is mounted on gold chassis and measures only 4.30 x 2.64 in. It is rated for 5 A (1/2 hp) with 115 Vac input and 10 A (1 hp) with addition of optional heatsink. Programmable chip sets range for acceleration, deceleration, current limit, and IR compensation trimmer pots. Inhibit function and jumper can adjust factory set trimmer pot ranges to fit smaller motors. M1 will follow...

Read More »
I/O Modules monitor periodic/pulse waveform signals.
Modules

I/O Modules monitor periodic/pulse waveform signals.

BusWorks(TM) 942MB I/O Modules capture periodic or pulse waveform signals from 2 sensor inputs for communication over Modbus network. Two discrete outputs with built-in solid-state relays can operate as independent local limit alarms or perform on/off switching functions under instructions from central controller. High-speed RS-485 transceivers support data transfer rates up to 115 Kbaud....

Read More »
Software Tools facilitate checkweighing.
Controls and Controllers

Software Tools facilitate checkweighing.

ReAct provides remote access to data stored within checkweighers, eliminating need to be physically present in production area. Data can be uploaded via Ethernet connection from MS Windows-based PC. LogInServer provides data needed for compliance with government regulatory mandates. Personalized and traceable log tracks user activities on system-wide basis. AccessCard offers single or 2-stage...

Read More »
Air Purifier filters out indoor pollutants.
Controls and Controllers

Air Purifier filters out indoor pollutants.

Heavy-duty room air purifier with variable fan speed control handles room volumes up to 2000 cubic ft. Made of steel with baked enamel finish, unit does not require outside venting and can be mounted on walls. Multistage Dacron and aluminum prefilters are available for gross particulate, and HEPA filters (99.99% effective on particulate down to 0.3 microns in size) are available for powders,...

Read More »
Measuring Wheel Hand Grip reduces operator strain.
Handles, Pulls and Levers

Measuring Wheel Hand Grip reduces operator strain.

Ergonomic, pistol-styled handgrip reduces wrist fatigue and provides wheel control in rough terrain or windy conditions. Design includes reduced-wear, clamp-lock mechanism for telescoping aluminum handle that permits handle to extend and retract in same relative position. Handle design is available on mechanical measuring wheels 10 in. or larger in diameter, which includes Series 31, 45, 60, and...

Read More »
AC Drive handles harsh washdown applications.
Motor Controllers and Drives

AC Drive handles harsh washdown applications.

Compact V74X adjustable frequency ac drive is available with NEMA Type 4X/12, IP66-rated enclosure. This makes drive suitable for use in installations where it is exposed to severe environmental conditions or hose-directed water, and indoor installations where dust is encountered or accumulated. Powder coated heatsink helps protect against erosion by harsh cleaning solvents used in food...

Read More »
I/O Module connects to Modbus or Profibus.
Modules

I/O Module connects to Modbus or Profibus.

I/O Pak(TM) IOPK-C112-U multifunction module has 4 universal analog input channels, one analog output channel and 2 discrete channels that can be used for inputs or outputs. DIN rail device can be configured for ACSII, Modbus RTU, or Profibus-DP communications. Module's math, logic, control, and diagnostic functions allow it to function as standalone controller or I/O processor, remote I/O for...

Read More »
Ethernet Cards offer bypass capability.
Interfaces

Ethernet Cards offer bypass capability.

PCI-8214 and PCI-8213 2/4 port Ethernet cards run on 64-bit, 33/66 MHz PCI bus, and are also compatible with 32-bit PCI slots. Bypass capability is designed for network monitoring and control. When system crashes, unexpected power-down, or on-board watchdog timer has timed out, on-board relays will cross-link channel 1 and 2. Fail-safe data transmission is achieved by linking inbound and outbound...

Read More »

All Topics

COVID-19 Response Suppliers COVID-19 Response:
Can Your Company Help Provide Critical Supplies?

We are using the power of our platform to aid in the mass shortage of critical supplies. If your company can help provide supplies, capabilities, or materials for products such as N-95 Masks and Tyvek SuitsPlease let us know.

COVID-19 Response Suppliers