Calibrators

Diagnostic Junction Box continuously monitors scales.

Diagnostic Junction Box continuously monitors scales.

NTEP-approved, digital iQUBE(TM) alerts technicians to potential scale inaccuracies. LEDs change from green to red to indicate suspect load cell and its specific location to help speed diagnosis and repair. Cell-Emulator(TM) compensates for connection errors and A/D drift and failures, and maintains scale operation until repair or load cell replacement is available. iQUBE is suited for new or...

Read More »
Multifunction Calibrator suits laboratory applications.

Multifunction Calibrator suits laboratory applications.

Dual-channel MicroCal 2000+ comes with CalpMan Plus software for calibration and documenting in compliance with ISO 9000. Additional offerings include MicroCal PM200 Module to generate/measure pressure, programmable signal converter, remote temperature probe, and 4-Wire resistance thermometer. Able to measure 14 different thermocouples, unit offers calculated readings and has 2 internal sensors...

Read More »
Gas Generator blends gas standards in laboratory.

Gas Generator blends gas standards in laboratory.

Model 491M dynamically blends calibration standards for trace sulfur and oxygenated compounds in carbon dioxide. Secondary dilution feature gives adjustable low ppb and ppt concentrations over 400:1 range with constant output flow. Unit can generate gas mixtures from permeation tubes, diffusion tubes, and compressed gas cylinders. Mixture concentrations are traceable to NIST through physical...

Read More »
Calibration Conditioner designed for load cells.

Calibration Conditioner designed for load cells.

Microprocessor-based Model SC2000 AM provides 1 or 2 channels and is calibrated against 8.5-digit, traceable digital voltmeter. Conditioner presents test and reference load cell measurements on split-screen display. Its 22-bit processor offers 19 bits of resolution that measures signals from up to 2 load cells. Unit connects to computer running load cell calibration software to generate...

Read More »

Humidity Calibration System uses chilled mirror technology.

NIST traceable Humilab(TM) verifies, calibrates, and documents humidity sensors. It utilizes time-proportioned divided-flow technique to achieve relative humidity stability of 0.2% RH. Built-in chilled mirror hygrometer continuously measures environment and provides feedback to microprocessor controller. Humilab provides accuracy of Â-

Read More »
Pressure Standard offers 0.008% accuracy.

Pressure Standard offers 0.008% accuracy.

Digiquartz Model 745 provides 25 absolute and gauge full scale pressure ranges from 15-40,000 psi. It features intuitive front panel menu system and 2-line display, which includes taring, engineering units, pressure bar graph, sensor temperature, rate of pressure change, resolution, and sampling speed functions. Password protected unit allows user to adjust number of display digits. It can be...

Read More »
Calibration Systems are IEEE 1451.4 compliant.

Calibration Systems are IEEE 1451.4 compliant.

Plug, Play, and Calibrate Systems are compliant to IEEE 1451.4 standard for connectivity of sensors and associated signal conditioning. Transducer electronic data sheet containing sensor specifications, calibration data, and user-defined location information is stored in sensor. When connected to SC2000 or any IEEE 1451.4 compliant signal conditioning, sensor is interrogated for TEDS information...

Read More »

Calibration System calibrates vibration sensors.

Self-contained, portable Model K9100C includes everything needed to calibrate displacement, velocity, and acceleration sensors when operated with user-supplied sensor signal conditioning. Two 10-turn potentiometers set test parameters for calibrating sensors in bandwidth from 10 Hz to 10 kHz. System produces NIST-traceable reports that comply with ISO 17025/A2LA requirements. Included...

Read More »
Calibration Station provides precise vision alignment.

Calibration Station provides precise vision alignment.

Backlit Calibration Station eliminates ghosting from dispensed dots and eliminates dot sheen when calibrating materials with reflective properties, resulting in more accurate dispense outline for vision alignment system calibration. Backlit calibration can be combined with topside lighting for additional alignment control. Continually refreshed calibration area is made possible by auto feed paper...

Read More »
Diagnostic System verifies calibration of flow meters.

Diagnostic System verifies calibration of flow meters.

Offered in portable, compact package, CalMaster on-site electronic system lets users obtain routine data of MagMaster(TM) performance and verify original calibration data. Unit carries out pre-programmed verification procedure and lets technicians review results and print out certificates of validation for meter under test. For each installed meter, product can perform diagnostics and...

Read More »