Valve prevents excess system pressure.

Press Release Summary:




Series C46 valve prevents excess system pressure by bypassing total system fluid flow. Valve consists of tapered plunger and valve seat, has no external springs or moving parts, is fully adjustable, and can be serviced in place without removing fittings or plumbing. Available with SS or brass body, valve can handle flow up to 10 gpm and pressure up to 1,500 psi.



Original Press Release:



Prevent Excess System Pressure with C46 Series Valves



MINNEAPOLIS, MN - C46 Series valves from Hydra-Cell Industrial Pumps, Wanner Engineering Inc., prevent excess system pressure by bypassing total system fluid flow. They contain no external springs or moving parts, are fully adjustable, and can be serviced in place without removing fittings or plumbing. They are available with stainless steel or brass bodies to suit various application needs.

The Hydra-Cell C46 Series valve design is simple, consisting of a simple tapered plunger and valve seat. When excess pressure overcomes the adjustable spring pressure on the plunger, the plunger lifts off the seat, allowing fluid to bypass and reduce the pressure. These valves are designed to handle flow up to 10 gpm and pressure to 1500 psi.

For more information contact: Hydra-Cell Industrial Pumps, Wanner Engineering Inc., 1204 Chestnut Ave., Minneapolis, MN 55403; Telephone: 612/332-5681; Fax: 612/332-6937; e-mail: sales@wannereng.com; or visit www.hydra-cell.com.

Tech Contact:
Tom West
(612) 313-7820
twest@wannereng.com

Press Contact:
Chris Nelson
(612) 237-4443
chris@longrenparks.com