Press Release Summary:



Made of stainless steel for sanitary applications, PIM Series Pump Diagnostic Pressure Sensor detects pump damage caused by cavitation, trapped air or gas, blockages, and deposits. Unit continuously monitors pump to provide numeric indication of operating system pressure and offers independent continuous diagnosis of pump's condition. High overload resistance of ceramic capacitive measuring cell enables sensor to be used for switch-off in case of overpressure.



Original Press Release:



Pump Diagnostic Pressure Sensor Detects Cavitation, Trapped Air and Blockages



ifm efector inc. introduces a new line of pump diagnostic pressure sensors that detect potential pump damage caused by cavitation, trapped air or gas, blockages and deposits. The PIM Series pressure sensor can perform two functions in one compact housing: pump monitoring and pressure detection. The sensor continuously monitors a pump to provide numeric indication of the operating system pressure and offers independent continuous diagnosis of the pump's condition.

Operating as a pump disgnostic sensor, the PIM sensor measures the high-frequency pulsations of a properly operating pump and stores it a a reference. If changes occur in the system, the pulsations will change. These changes are immediately detected by the sensor. If a critical pump condition occurs, such as cavitation, the sensor will provide an alarm signal to a controller. ifm's condition-based pump monitoring sensor increases machine uptime and reduces damage caused by poor pump operating conditions. In addition to monitoring a pump, any disturbances around the pump such as trapped air in the medium, clogged filters, deposits in pipes or improperly opened valves are also monitored.

The sensor and its teach function are quickly setup using the numeric pushbutton display. The sensor's display alternately provides the numeric system pressure and the operating state of the pump via a trend display that graphically depicts the operating state of the pump.

The sensor's second output can be configured as a switching output with hysteresis or window function or as a scaleable analog output. Due to the high overload resistance of the ceramic capacitive measuring cell, the sensor is especially suited for switch-off in case of overpressure. FDT programming software enables the display of the measured values, analog output, limit values and the parameter setting of the thresholds for diagnosis.

The stainless steel PIM pressure sensor is designed for sanitary applications and uses a variety of sanitary adapters for a secure fitting in washdown, CIP and SIP conditions. The sensor is 3A authorized and meets FDA and EHEDG requirements. A variety of M12 cable assemblies designed specifically for washdown conditions are available from ifm.

List price for the PIM sensors is $573.00 (US). Sanitary adapters range from $55.00 to $211.00 (US)and Micro DC washdown cable assemblies are $23.00 to $31.00 (US).