Optical Interconnection System is CFP-compliant.

Press Release Summary:




Addressing thermal management and EMI management requirements of MSA, CFP-Compliant Interconnection System includes module plug connector that straddle-mounts to board within transceiver module, and host receptacle connector, which surface mounts to host board. Two-piece, 148-position unit offers signal integrity over 20 differential pairs to support 4-channel 40 Gbps and 10-channel 100 Gbps operation. Applications include switches and routers for telecom and data centers.



Original Press Release:



Interconnect System for CFP Optical Transceivers



The CFP-compliant interconnection system from Tyco Electronics provides a pluggable solution for 40- and 100-Gb/s Ethernet applications. Pluggable CFP-compliant transceivers will support the ultrahigh bandwidth requirements of data communications and telecommunication networks.

Product Features

o 10X solution using Tyco Electronics high speed 148 position connector, supporting 10Gb/s per channel.

o Plug connector straddle mounts to the optical transceiver module pcb for conventional processing

o Design supports belly-to-belly port positioning

Applications

o Switches and Routers for Telecom and Data Centers

o Optical Transport Equipment for Long Haul, Metro and Multiservice Provisioning Platform Applications.

HARRISBURG, Pa. - The CFP-compliant interconnection system from Tyco Electronics provides a pluggable solution for 40- and 100-Gb/s Ethernet applications. The CFP-compliant interconnection components include a transceiver module plug connector, a host receptacle connector installed on the host board and associated guide rails, receptacle cover, external bracket assembly, backer plate assembly, and a riding heat sink.

Created by leaders in optical transceivers, the CFP MSA specification defines a hot-pluggable optical transceiver form factor to enable 40- and 100-Gb/s Ethernet applications. Pluggable CFP-compliant transceivers will support the ultra-high bandwidth requirements of data communications and telecommunication networks. Target equipment includes routers, switches, and optical transport equipment for applications ranging from long haul to data centers.

"All components of the interconnection system were developed working in conjunction with the CFP MSA specification. Tyco Electronics is continuing to demonstrate its commitment to supporting next-generation, ultra-high-speed pluggable interface developments. We have worked closely with CFP MSA specifications to develop a system that provides the challenging levels of electrical and mechanical performance required by this next-generation interface," states Michael Walmsley, Tyco Electronics product manager.

The CFP-compliant interconnect system addresses the advanced thermal management, EMI management, and signal integrity requirements of the MSA. The CFP-compliant connector is a 148-position, two-piece connector system offering state-of-the-art signal integrity performance levels over 20 differential pairs to support four-channel 40-Gb/s and ten-channel 100-Gb/s operation. The module plug connector straddle mounts to the board within the transceiver module, and the host receptacle connector surface mounts to the host board.

The receptacle cover and the external bracket assembly both contain integrated EMI containment features to ease the task of EMI compliance for the OEM line card designers. Additionally, the CFP-compliant connector system is designed to enable belly-to-belly (double-sided) implementation for higher line card density. A riding heat sink supports CFP optical transceivers that require additional thermal management.

Drawings and pricing can be provided upon request. For more information on Tyco Electronics CFP interconnection system, contact Tyco Electronics Product Information Center at 800-522-6752, or visit http://www.tycoelectronics.com/help.

All Topics