Multifunction Safety Controller monitors up to 6 zones.
Press Release Summary:
As interface between Tapeswitch sensing devices and machine or process control, C6 safety controller monitors up to 6 zones consisting of 1-3 B-Series Light Curtains and/or 1-6 other sensing devices. Unit detects sensor, cabling, or internal faults; offers automatic/manual reset options; and provides visual status display of all zones. Supplied in metal enclosure, fully self-contained unit is designed to be wall mounted and has 6 knockouts that accept standard ½ or ¾ in. conduit.
Original Press Release:
C6 Multifunction Safety Controller
The C6 Multifunction Safety Controller acts as an interface between various Tapeswitch sensing devices and a machine or process control. It is designed to monitor up to six zones consisting of 1 to 3 B-Series Light Curtains and/or 1 to 6 other sensing devices. The C6 safety controller provides power to all connected B-Series Light Curtain emitters and receivers and monitors the output signals. In addition to the light curtains, the C6 safety controller interfaces with various pressure-sensitive, normally-open switches made by Tapeswitch including ribbon switches, sensing edges/bumpers, and switching mats.
Features & Benefits
The C6 safety controller incorporates built-in fault protection. It automatically detects an open or short within the sensor or its connecting cable and can also detect internal failures.
The C6 safety controller is a fully self-contained unit housed in a rugged metal enclosure. It is designed to be wall mounted and has six knockouts that accept standard 1/2" or 3/4" conduit. It will accept an input power source range of 85 to 264 Vac at an input frequency range of 47 to 63 Hz. The unit will also accept a regulated 24 Vdc supply.
Technical Specifications for C6 Safety Controller
Supply Voltage: 110/240 Vac 50/60 Hz or 24 Vdc
Power Consumption: 30 VA typical
Enclosure Type: Metal wall mount
Protection Rating: NEMA 1/IP10 (Standard), NEMA 12/IP52 (Optional)
Weight: 9.5 lb (4.3 kg)
Reset Mode: Automatic, manual, or combination
Output Relays: Force guided safety relays
6.0 A @ 240 Vac, resistive load
Monitor Output: Non-safety 6X (N/O or N/C)
10 A @ 240 Vac, resistive load
Operating Temperature: 32 to 122 °F (0 to 50 °C)
Response Time: 10 ms