Lever-Actuated Fuse Holders offer vibration-proof connections.

Press Release Summary:



Accommodating 14–6 AWG conductors, touch-safe 811 Series is available in 1–3 poles, with optional coupling kit for multi-pole configurations in field. Class CC model supports branch-circuit applications with up to 200 kA SCCR (30 A, 600 V), while Midget style achieves 100 kA SCCR (30 A, 750 Vac/1,000 Vdc) for supplemental protection. Featuring DIN-rail mount clip for installation and removal, lever-actuated devices replace traditional screw-based terminations with CAGE CLAMP® Spring Pressure.



Original Press Release:



WAGO Lever-Actuated Fuse Holders



WAGO Lever-Actuated Class CC, Midget-Style Fuse Holders



GERMANTOWN, WI – WAGO Corporation’s 811 Series Class CC and Midget-Style (10x38mm) Fuse Holders provide machine- and panel-builders with a new approach to branch and supplemental protection. The lever-actuated units replace traditional screw-based terminations with an industry-first application of CAGE CLAMP® Spring Pressure. Beyond maintenance-free, vibration-proof connections, these lift-and-lock terminations reduce wiring times up to 50% — no torque specs or specialty tools.



Up to 1,000 V DC:

Accommodating conductors 14–6 AWG, 811 Series is available in 1–3 poles; an optional coupling kit creates multi-pole configurations in the field. The Class CC Fuse Holder supports branch-circuit applications with up to 200 kA SCCR (30 A, 600 V). The Midget-style variant achieves 100 kA SCCR (30 A, 750 V AC/1,000V DC) for supplemental protection — the 1,000 V DC, 1-pole model is ideal for PV combiner boxes.



The touch-safe 811 Series features a DIN-rail mount clip for easy install or removal. Each Holder carries a test point at each conductor entry for general testing. Circuit identification/marking options are provided by WAGO’s WMB multi-marking strip and exclusive continuous marking strip adapters. 811 Series carries UL, CSA and IEC listings, recognitions and certifications.



Response to Market Trends:

811 Series responds to two recent trends: Adoption of more compact Class CC Fuses over Class J Fuses, and Defined Short Circuit Current Rating (SCCR) requirements. SCCR requirements in NEC Article 409 and UL 508A have spurred demand for fuse-based, branch-circuit protection in control panels. Providing easier integration than traditional circuit breakers, fuses also facilitate higher SCCR ratings. For example, many terminal blocks tested with fuses earn a 100 kA rating; the same terminal block tested with a circuit breaker might only achieve a 65 kA.



For more information, call 1-800-DIN-Rail, email info.us@wago.com, or visit www.wago.us/811fuse.htm .