Leak/Flow Standards are traceable to NIST.

Press Release Summary:




Series 520 is available in 5 mounting assemblies: I-Inline, G-General, 21-Straight Thread, C20-CPC, and C20F/C-Miniature assembly. Individually sized and manufactured to ISO 17025 within 0.5 to 50,000 sccm range and within -14.7 to 500 psig range, each calibrated orifice is certified as air leak or flow standard in company's accredited laboratory. Applications include test instruments, mounting into master calibration parts, or plugging into production test line.




Original Press Release:



Calibrate or Verify Calibration of Leak and Flow Instruments



Cincinnati Test Systems, Inc., Village of Cleves, Ohio, offers their newest series 520 Calibrated Leak/Flow Standards in five mounting assemblies: I-Inline Assembly, G-General Assembly, 21 -Straight Thread Assembly (for Sentinel B-21 and 1-21 instruments), C20-CPC Assembly (for Sentinel C-20-S instruments) and C20F/C-Miniature Assembly (for Sentinel C-20-F/C instruments). Individually sized and manufactured to ISO 17025 within 0.5 to 50,000 sccm range and within -14.7 to over 500 psig range, each calibrated orifice is certified as an air leak or flow standard in Cincinnati Test Systems' A2LA accredited laboratory and sealed in a specified mounting assembly.

Applications include integration into test instruments, mounting into master calibration parts or plugging into a production test line. Calibrated Leak/Flow Standards from Cincinnati Test Systems are traceable to NIST standards and provide 1.2% accuracy. They are shipped with a calibration certificate in five working days. All assemblies include an inlet filter and most include an exhaust filter.

Each calibration standard should be re-certified/re-calibrated periodically to maintain accurate testing. Re-certification is a verification of the current flow rate as compared to previous calibration and/or original specified values. If the current flow value is outside the allowable tolerance range, a new standard is supplied with a flow value ±1% of the last calibrated value. A new NIST/A2LA certification for the measured flow value is issued.

Cincinnati Test Systems is a leading manufacturer of Pressure Decay, Mass Flow and Mass Spectrometer leak detection equipment and produces a full line of Sentinel Leak Detection Instruments. A Calibrated Leak/Flow Standard Specification Sheet is available by contacting sales@cincinnati-test.com. Or you can write, phone or fax Cincinnati Test Systems, Inc., 5555 Dry Fork Road, Village of Cleves, Ohio 45002, phone: 513-367-6699, fax: 513-367-5426. Or visit our web site @ cincinnati-test.com/orifices.htm.