Coating Thickness Gage validates measurement conformance.

Press Release Summary:




PosiTector® 6000 offers SSPC PA2 feature set in memory models that helps determine if film thickness over extended area conforms to user-specified Min and Max levels. Through PA2 Setup menu, user can specify Min and Max thickness, number of readings in one spot, number of spots in batch, and allowable deviance. Stored results can be viewed on display, modified, or deleted, and formatted printout can be sent to optional IR printer. Results can also be downloaded to PC via USB cable.



Original Press Release:



New PosiTector 6000 PA2 Feature



The redesigned PosiTector® 6000 Coating Thickness Gage from DeFelsko Corporation now offers an advanced SSPC PA2 feature set in memory models. This new feature makes it easier than ever to determine if film thickness over an extended area conforms to user-specified minimum and maximum levels.

PA2 recommends that a coated surface be sectioned into one or more large test areas. A minimum of 15 individual measurements are taken in 5 groups of 3 measurements each. Suggestions are made as to the acceptability of individual measurements, spot measurements (the average of each group), and the calculated average of the spot measurements. In simple terms, PA2 suggests the average of a series of average values be used to determine if a target thickness has been met.

The PosiTector 6000 PA2 Setup menu allows the user to specify a minimum thickness, maximum thickness (if applicable), number of readings in a spot, number of spots in a batch, and percent below/above the minimum and maximum values each "spot" is allowed to fall between.

Stored results can be viewed on the display, modified or deleted. A formatted printout can be sent to the optional IR printer or results can be downloaded to a PC using the included PosiSoft software and USB cable.

Call DeFelsko at (800) 448-3835 or visit our website at www.defelsko.com for further information.