5128A RHapid-Cal Humidity Generator provides six-point calibration in two hours.

Press Release Summary:

Used for calibrating probes and loggers in the field or in laboratory, 5128A RHapid-Cal Humidity Generator is suitable for pharmaceuticals, medical devices, semiconductors, chemicals, and food production industries. Offering ± 1.0% RH system accuracy for dependable humidity probe calibration, unit provides rapid humidity and temperature stabilization time 10ºC/minute and 1.5ºC/minute for increase and decrease in temperature respectively.


Original Press Release:

Fluke Calibration 5128A RHapid-Cal Humidity Generator Calibrates Probes with Accredited One Percent RH System Accuracy

Portable humidity generator delivers fast, accurate multi-point calibration of humidity probes and loggers

Fluke Calibration introduces the 5128A RHapid-Cal Humidity Generator, a portable, versatile humidity generator for calibrating a large workload of probes and loggers in the field or in the laboratory. The 5128A is ideal for corporate and independent calibration labs where humidity measurement is critical to prevent spoilage of products, including pharmaceuticals, medical devices, semiconductors, chemicals, and food production.

The 5128A is lightweight and compact so technicians can easily take it to the field for thorough, reliable multi-point calibration of humidity probes and loggers. In the lab, the 5128A reduces calibration time by at least 33 percent compared to traditional two-pressure humidity generators, which are slower to respond to humidity and temperature set point changes.

The 5128A delivers:

  • Best-in-class system accuracy of ± 1.0% RH for dependable humidity probe calibration
  • Rapid humidity and temperature stabilization time for high calibration throughput
    • Rate of change for temperature increase is typically 10 ºC/minute; for temperature decrease 1.5 ºC/minute.
    • Rate of change for humidity increase is typically 10% RH/minute; for decrease 5% RH/minute.
    • A six-point calibration can be done in two hours.
  • Easy maintenance
    • A front-loading desiccant cartridge can be easily changed by removing the front cap and sliding in a new one.
    • Only clean distilled water is needed to operate the 5128A.

The 5128A RHapid-Cal comes standard with an ISO 17025 accredited system calibration and is backed by Fluke Calibration's world-class metrology and support.

To learn more about Fluke Calibration 5128A RHapid-Cal Humidity Generator, visit http://us.flukecal.com/5128A.

Contact Fluke Calibration

For more information about Fluke Calibration, visit the Fluke Calibration website or contact Fluke Corporation, P.O. Box 9090, Everett, WA USA 98206-9090, or call 1-877-355-3225.

About Fluke Calibration

Fluke Corporation is a leader in precision calibration instrumentation and software for electrical, temperature, humidity, pressure, flow, and RF measurements. Fluke Calibration products from Fluke Corporation are found in calibration facilities around the world, including National Metrology Institutes, that demand the highest levels of performance and reliability, backed by state of the art metrology and uncompromising support. They are relied on by quality engineers, calibration technicians, and metrologists to instill confidence in the measurements that are critical to their organizations for quality, safety, reliability, and cost.

For more information:

Dan Wright

Communications Manager

(425) 446-5638

dan.wright@fluke.com

Web Site: http://flukecal.com/

Download Spec Sheet

All Topics