Area Sensors detect objects in non-safety applications.
Sensors, Monitors & Transducers

Area Sensors detect objects in non-safety applications.

Series AS6000 features 15 m range, response time of 24 ms, and 31 x 32 mm cross section to detect objects as small as 30 mm in diameter. Offering NPN or PNP outputs, sensors are capable of switching high current loads to 250 mAdc and can interface to almost any control system. Industry-standard M12 connectors facilitate installation. Sensors are suited for factory automation applications...

Read More »
Sensors, Monitors & Transducers

Muting System facilitates entrance/exit guarding.

Integrated into any entrance or exit conveyor, IMS Safety Muting System distinguishes between material and people entering dangerous area. Differentiation is achieved by arranging muting sensors such that only particular combination of signals triggered by incoming material allows system to enter safety-muted state. Immediate machine stop is triggered if proper sensor sequence or combination does...

Read More »
Safety Light Curtain offers 14 mm resolution.

Safety Light Curtain offers 14 mm resolution.

MegaSafeÂ-® MG4600 provides detection capabilities from 14 mm finger to 50 mm arm detection. Protected heights range from 435-2,086 mm and sensing range is 7.5-20 m. MegaSafeÂ-® MG4600 includes Individual Beam Indicators to facilitate alignment, field-replaceable safety relays and weld shield, Floating Blanking to block up to 2 beams anywhere in zone, and Exact Channel Select to...

Read More »
Relays suit safety monitoring applications.
Electrical Equipment & Systems

Relays suit safety monitoring applications.

Fixed terminal relays, Series SR 1000 and removable terminal relays, Series SR 2000 work with many configurations and switching arrangements to meet requirements of safety systems. They accept inputs from variety of safety devices such as E-stops, interlocks, safety mats, and light curtains. Units offer 1, 2, or 3 adjustable time delay outputs for applications requiring time-delayed stop...

Read More »
Perimeter Access Guarding Device offers 30 m range.
Architectural & Civil Engineering Products

Perimeter Access Guarding Device offers 30 m range.

Explosionproof Perimeter Access Guarding Device PA4600-EP features 16 ms response time and 2 PNP safety outputs designed to directly switch machine primary control elements. Selection of scan codes allows installer to choose scan frequencies, avoiding cross-talk with adjacent systems or other IR emitting devices. Offering torso detection, multiple-beam system is suitable for safeguarding...

Read More »
Datalogger provides high accuracy in harsh environments.
Test & Measurement

Datalogger provides high accuracy in harsh environments.

Data Dolphin 128 incorporates 24-bit, A/D section that provides 8 differential bipolar inputs with resolution down to 90 nV, allowing sensors to be directly connected without signal conditioning. Additional 4 inputs, with static protection, allow user to select pulse, status, or analog capability. Housed in waterproof case, product offers 1 Mb nonvolatile flash memory and uses Data Dolphin...

Read More »
Interlock Switch/Control Unit suits Category 3 applications.
Electrical Equipment & Systems

Interlock Switch/Control Unit suits Category 3 applications.

Series CM magnetically-coded, non-contact safety interlock switch and control unit features NEMA 6 encapsulated design and is tamper-resistant. Model CM-S4 control provides external device monitoring and has automatic reset button, which allows it to replace safety relay in most applications. Unit will monitor up to 4 switches to Category 3 in accordance with EN954-1. Switch and actuator come in...

Read More »
Control Unit and Switch provide complete Category 4 system.
Agricultural & Farming Products

Control Unit and Switch provide complete Category 4 system.

Suited for applications with up to 4 guard doors, EC Series Electrically Coded Interlock Switch and Control Unit consists of coded actuator, read head (switch), and control unit. Uniquely coded element cannot be reprogrammed, securing actuators against manipulation. System provides External Device Monitoring and may be operated in manual or automatic start mode. Multiple units can be linked...

Read More »
Protective Light Curtain guards low-risk equipment.

Protective Light Curtain guards low-risk equipment.

With control circuitry housed within transmitter and receiver, MiniProtect MP2100 provides Type 2 guarding. Factory selectable operating modes allow unit to be used in point of operation or perimeter guarding applications. Characteristics include 30 mm resolution, 15 m range, and protected heights from 147-1470 mm. Compact design has adjustable mounting brackets, 2 solid-state safety outputs, and...

Read More »
Safety Interlock Switch features narrow metal housing.
Electrical Equipment & Systems

Safety Interlock Switch features narrow metal housing.

Model TL4024, with guard door locking, provides locking force of 337 lb and uses 4 contacts to monitor safety, door position, and lock status. When used with stainless steel actuator, it delivers minimum of 1 million actuations. NEMA 6 anodized die-cast metal housing allows switch to withstand washdown environments, and rotatable head provides 8 actuator entry points. Narrow profile facilitates...

Read More »