Lytron, Inc.

Display & Presentation Equipment

Lytron's Engineering Lab Develops IGBT Test Stand for Measuring Cold Plate Thermal Performance

IGBT Test Stand for Measuring Cold Plate Thermal Performance - Woburn, MA, USA: Before custom cold plate prototypes leave Lytron's factory, the actual thermal performance of the cold plates can now be measured using an in-house Insulated Gate Bipolar Transistor (IGBT) test stand. In cases where IGBT-to-IGBT temperature uniformity impacts the IGBT's function, Lytron can also validate temperature...

Read More »
Display & Presentation Equipment

Lytron Purchases State-of-the-Art Vibration Test Stand

Woburn, MA, USA: Lytron recently announced that it has purchased a state-of-the art vibration test stand to further expand its in-house environmental testing capabilities. The vibration test stand allows Lytron to offer shock and vibration testing, also known as dynamics testing, to its Original Equipment Manufacturer (OEM) customers in the commercial aviation, military, and traction industries....

Read More »
Coolant Distribution Unit cools data center racks.
Electronic Components & Devices

Coolant Distribution Unit cools data center racks.

With 150 kW cooling capacity, LCS50 liquid-to-liquid cooling system supplies coolant at precisely controlled temperatures to liquid cooled racks and transfers waste heat to facility water. Coolant is delivered to rack, equipment, and electronics above dew point, minimizing risk of condensation. Measuring 24.0 x 48.0 x 77.5 in., unit has 3 temperature control schemes, including control to dew...

Read More »
Cold Plates are fully compatible with water coolant.

Cold Plates are fully compatible with water coolant.

Ascent(TM) Series all-copper cold plates provide contact cooling of high watt-density electronic components such IGBTs, MOSFETs, resistors, and diodes. Normalized thermal resistance at 1 gpm is 0.58°C inÂ-²/W, and pressure drop at 0.5 gpm is 3 psi. Internal crisscrossed fin structure offers increased surface area. Available with straight or beaded fittings, plates are pressure tested...

Read More »
Heat Exchangers are pressure tested to 150 psi.
Material Processing

Heat Exchangers are pressure tested to 150 psi.

OEM Coil Series Copper Tube-Fin Heat Exchangers range from 20W/°C at Â-½ gpm to 250W/°C at 4 gpm. Seamless copper tubing is expanded into aluminum fins for thermal connection. Liquid circuit is silver brazed and finned tubes are assembled into galvanized steel frame. Six configurations are available with beaded, straight tube, or 37° flare nut fluid connections. Air side...

Read More »
Chiller has temperature stability of ±0.05°C.
HVAC

Chiller has temperature stability of ±0.05°C.

Kodiak® recirculating chiller provides immediate response to setpoint change. Its controller allows pressure units (PSI and BAR) to be set independent of temperature units (°F and °C). Chiller, available with cooling capacities from 600 to 6,500 W, uses common coolants and offers pressure display, reservoir level indicator, and low flow sensing. It suits analytical instruments,...

Read More »
Cold Plates suit high-watt density applications.

Cold Plates suit high-watt density applications.

High Performance Series(TM) cold plates offer corrugated aluminum fins, which provide heat transfer surface. Vacuum brazing produces parts with uniform thermal conductivity over large surface area. Cold plates may be customized to any application and are available in sizes from 4 to 700 inÂ-² (as thin as 0.10 in.). They are manufactured by inserting aluminum fin into aluminum plate with...

Read More »
Heat Exchangers come with 90° bends.

Heat Exchangers come with 90° bends.

Models 4000 and Aspen stainless steel heat exchangers are suitable for deionized water and other corrosive liquids that react with copper. Both models are available with 90° deg bends on inlet/outlet tubes. Various fittings allow tubing connections to be configured into 24 different orientations. Applications include medical and industrial lasers, medical imaging, analytical instruments,...

Read More »
Cold Plates fit in small spaces.

Cold Plates fit in small spaces.

Press-Lock II(TM) series uses smaller, tightly packed tubes to improve thermal performance by 40 to 50% over company's previous models. Plates are 0.3 in. thick and tubes are 0.25 in. dia, allowing for tight packaging and stack construction. Tubes are coplanar with plate, allowing parts to be mounted on both sides. Applications include cooling electronics, power supplies, lasers, RF transmitters,...

Read More »
Display & Presentation Equipment

Lytron's Engineering Lab Develops IGBT Test Stand for Measuring Cold Plate Thermal Performance

IGBT Test Stand for Measuring Cold Plate Thermal Performance - Woburn, MA, USA: Before custom cold plate prototypes leave Lytron's factory, the actual thermal performance of the cold plates can now be measured using an in-house Insulated Gate Bipolar Transistor (IGBT) test stand. In cases where IGBT-to-IGBT temperature uniformity impacts the IGBT's function, Lytron can also validate temperature...

Read More »
Mergers & Acquisitions

Lytron Acquires Lydall Industrial Thermal Solutions, Inc ("Affinity")

June 30, 2011, Woburn, MA, USA: Lytron announced today that it has completed the acquisition of Lydall Industrial Thermal Solutions, Inc ( Affinity") from Lydall, Inc (NYSE). Affinity is a leading designer and manufacturer of high performance industrial chillers and liquid-to-liquid cooling systems for the semiconductor, laser, and industrial markets. Craig Carswell, President and CEO of Lytron...

Read More »
Display & Presentation Equipment

Lytron Purchases State-of-the-Art Vibration Test Stand

Woburn, MA, USA: Lytron recently announced that it has purchased a state-of-the art vibration test stand to further expand its in-house environmental testing capabilities. The vibration test stand allows Lytron to offer shock and vibration testing, also known as dynamics testing, to its Original Equipment Manufacturer (OEM) customers in the commercial aviation, military, and traction industries....

Read More »
Coolant Distribution Unit cools data center racks.
Electronic Components & Devices

Coolant Distribution Unit cools data center racks.

With 150 kW cooling capacity, LCS50 liquid-to-liquid cooling system supplies coolant at precisely controlled temperatures to liquid cooled racks and transfers waste heat to facility water. Coolant is delivered to rack, equipment, and electronics above dew point, minimizing risk of condensation. Measuring 24.0 x 48.0 x 77.5 in., unit has 3 temperature control schemes, including control to dew...

Read More »
Company News

Lytron Opens New Factory & Corporate Offices in Woburn, Massachusetts

September 20, 2006, Woburn, MA: Lytron, Inc. recently announced the completion and opening of its new factory and corporate office space in Woburn, Massachusetts. With this new space north of Boston, Lytron has doubled its square footage and increased its manufacturing capabilities, positioning itself for continued growth. It has also made room for equipment and the addition of staff from its...

Read More »
Mergers & Acquisitions

Lytron Announces Strategic Acquisition to Expand Custom Cold Plate Capabilities

May 1, 2006, Woburn, MA: Lytron, Inc., a leading supplier of liquid cooling products to OEMs around the world, announced today the acquisition of Lockhart Industries, Inc., a subsidiary of Wakefield Thermal Solutions. Based in Paramount, California, Lockhart designs and manufactures advanced aluminum-brazed cooling components for the military and electronics markets. Lytron plans to move and...

Read More »
Cold Plates are fully compatible with water coolant.

Cold Plates are fully compatible with water coolant.

Ascent(TM) Series all-copper cold plates provide contact cooling of high watt-density electronic components such IGBTs, MOSFETs, resistors, and diodes. Normalized thermal resistance at 1 gpm is 0.58°C inÂ-²/W, and pressure drop at 0.5 gpm is 3 psi. Internal crisscrossed fin structure offers increased surface area. Available with straight or beaded fittings, plates are pressure tested...

Read More »
Heat Exchangers are pressure tested to 150 psi.
Material Processing

Heat Exchangers are pressure tested to 150 psi.

OEM Coil Series Copper Tube-Fin Heat Exchangers range from 20W/°C at Â-½ gpm to 250W/°C at 4 gpm. Seamless copper tubing is expanded into aluminum fins for thermal connection. Liquid circuit is silver brazed and finned tubes are assembled into galvanized steel frame. Six configurations are available with beaded, straight tube, or 37° flare nut fluid connections. Air side...

Read More »
Chiller has temperature stability of ±0.05°C.
HVAC

Chiller has temperature stability of ±0.05°C.

Kodiak® recirculating chiller provides immediate response to setpoint change. Its controller allows pressure units (PSI and BAR) to be set independent of temperature units (°F and °C). Chiller, available with cooling capacities from 600 to 6,500 W, uses common coolants and offers pressure display, reservoir level indicator, and low flow sensing. It suits analytical instruments,...

Read More »
Cold Plates suit high-watt density applications.

Cold Plates suit high-watt density applications.

High Performance Series(TM) cold plates offer corrugated aluminum fins, which provide heat transfer surface. Vacuum brazing produces parts with uniform thermal conductivity over large surface area. Cold plates may be customized to any application and are available in sizes from 4 to 700 inÂ-² (as thin as 0.10 in.). They are manufactured by inserting aluminum fin into aluminum plate with...

Read More »

All Topics