Torrey Pines Scientific, Inc.

Vibration Free Incubator is suited for protein crystallography.
Health, Medical, & Dental Supplies and Equipment

Vibration Free Incubator is suited for protein crystallography.

Peltier-based for heating and cooling, EchoTherm(TM) benchtop chilling incubators have 4-70°C temperature range and come in 2 fully programmable models and 2 models that offer simplified digital controls. All models, which are accurate to 0.1°C, do not have compressors or CFCs and are suited for life science laboratory applications. The 27.5 L units have 10 x 14 x 12 in. chamber can...

Read More »
Shaking Chilling/Heating Dry Bath is fully programmable.
Architectural & Civil Engineering Products

Shaking Chilling/Heating Dry Bath is fully programmable.

Intended for use with biological and other samples, EchoTherm(TM) Model SC25XT features 5-program memory and temperature range of -20 to +100°C. Unit employs variable-speed orbital shaker for mixing samples while controlling sample temperature to 1Â-ºC. Additional features include 30-day countdown timer with alarm and Auto-off, data logger, and RS232 I/O port. Peltier driven for...

Read More »
Architectural & Civil Engineering Products

Compact Chilling/Heating Dry Baths support remote control.

Measuring 6.5 x 4.75 x 3.5 in. without sample block, Peltier-driven EchoTherm(TM) RIC20 Series is designed for remote controlled applications on robotic and benchtop systems using PC. Any number of RIC20s can be used via RS232 I/O port on each unit and PC serial ports, and complex, user-created temperature/time profiles can be run by leaving computer attached to RIC20. Temperatures can be set...

Read More »
Programmable Hot Plate features milled-flat aluminum top.
HVAC

Programmable Hot Plate features milled-flat aluminum top.

Suited for heating silicon wafers, electronic chips, displays, and adhesives, EchoTherm(TM) HP40A is programmed via front panel membrane switch and custom LCD. Digital unit can store 10 programs in memory of as many as 10 steps each, where each step includes temperature, temperature ramp rate, and time. Measuring 8 x 8 in., cast aluminum heater plates can be evenly heated from ambient to...

Read More »
Hot Plates and Stirring Hot Plates handle large samples.
HVAC

Hot Plates and Stirring Hot Plates handle large samples.

Available in 100, 115, and 230 Vac, 50/60 Hz versions, EchoTherm(TM) HP61 and HS61 feature 10 program memory with 10 steps per program, temperature ramping, RS232 I/O port, membrane keyboard, and full-function LCD where all parameters are continuously visible. Heater tops, offered in ceramic or milled-flat cast aluminum, are 12 x 12 in. with 1,400 W heaters. Temperatures can be set to 450°C...

Read More »
Digital Stirring Hot Plate provides 5 stirring positions.
HVAC

Digital Stirring Hot Plate provides 5 stirring positions.

Suited for laboratories where reproducible, hands-off sample preparation and experimentation are required, EchoTherm(TM) Model HS65 features 12 x 12 in. solid ceramic glass heater plates that can be heated from ambient to 400°C. Stirring speed is 100-1,500 rpm and controlled by optical coupler to 10 rpm. With Model HS65, programming is done through front panel membrane switch and...

Read More »
Chilling/Heating Incubators offer temperature ramping feature.
Health, Medical, & Dental Supplies and Equipment

Chilling/Heating Incubators offer temperature ramping feature.

Designed with no compressors or CFCs, Peltier-based Models IN35 and IN45 have 27.5 and 55 L volume, respectively, with temperature range of 4.0-70.0°C and control to 0.1°C. Fully programmable controls can store 3 routines in memory with each routine capable of 10 steps. Each program can be made to repeat 1-99 times automatically. Available in 100, 115, and 230 Vac, 50/60 Hz models,...

Read More »
Chilling/Heating Dry Baths interface with robotic systems.
Architectural & Civil Engineering Products

Chilling/Heating Dry Baths interface with robotic systems.

Available with 1 or 2 chilling/heating positions, Peltier-driven Chilling/Heating Dry Baths utilize RS232 interface for robotic systems. Units can freeze, chill, or heat samples from -20 to +110°C in assay plates, centrifuge tubes, vials, and most any size test tube. Available in sizes down to 6.5 x 8.75 x 3.5 in., baths feature digital display and control of temperature to 1°C, data...

Read More »
Chilling/Heating Dry Bath features Peltier-driven design.
Architectural & Civil Engineering Products

Chilling/Heating Dry Bath features Peltier-driven design.

Measuring 6.5 x 8.75 x 3.5 in., EchoTherm(TM) Model IC20XR can freeze, chill, or heat samples from -10 to 110°C in assay plates, centrifuge tubes of all sizes, vials, and most any size test tube. Unit features digital display and control of temperature to 1°C, countdown timer, data logger, and RS232 interface to control unit by computer or to record data. Dry bath is suited for...

Read More »
HVAC

Hot Plates and Stirrers offer up to 9 positions.

Featuring 12 in. square ceramic heater tops, Analog Stirring Hot Plates have temperature range up to 450°C. Five-position stirring unit can stir 5-800 ml beakers, while 9-position unit can stir 9-500 ml beakers of aqueous solutions with stirring range from 100-1,500 rpm. Available in 100 Vac/50 Hz, 115 Vac/60 Hz, 220 Vac/60 Hz, and 230 Vac/50 Hz, hot plates support more than 50 lb on plate...